Preliminary results of tibial bone transports with pulsed low intensity ultrasound (Exogen™)

被引:27
|
作者
Gold, SM [1 ]
Wasserman, R [1 ]
机构
[1] Harbor UCLA Med Ctr, Dept Orthopaed Surg, Torrance, CA 90509 USA
关键词
ilizarov; bone transport; tibial segmental defects; nonunion; low intensity pulsed ultrasound;
D O I
10.1097/00005131-200501000-00003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: This study assessed whether the use of noninvasive, pulsed low intensity ultrasound (Exogen(TM)) reduced external fixation time for bone transport patients with large, segmental tibial defects. Design: This was a prospective study compared to a previously treated control group. Setting: All surgeries and postoperative care were done at the senior author's hospital facilities. Patients/Participants: Eight patients with large tibial segmental defects, acute or chronic, were studied. All patients were male, mean age 34 years (range 18-50). Intervention: All patients were treated with a single-level bone transport. Bone transports started 5 to 10 days after a metaphyseal corticotomy and progressed with one-quarter millimeter advancement 2 to 4 times per day. Exogen was applied to the regenerate site in the second postoperative week and to the docking site after docking was complete. The treatment was used for 20 minutes daily at each site. The patients were followed weekly for the first 4 weeks. They were then followed bimonthly for 2 months and then monthly until consolidation had occurred. Main Outcome Measures: The 2 main outcome measures used were the external fixation time measured in months and the external fixation index (time in the frame per cm of bone transported) measured in months per cm. Results: The mean follow-up from frame removal to the time of the last clinic visit was 12.4 months (range 4-32). The mean external fixation time was 13.91. The mean external fixation index was 1.34 months per cm transported for the Exogen group and 2.02 months per cm for the control group. Although not statistically significant because of small numbers, the external fixation index was reduced by 17.21%. Conclusion: These data further confirm already published data on the acceleration of fracture healing by low intensity Pulsed ultrasound and, in our case, regenerate consolidation. Shorter treatment periods reduce complications and expenses and return patients back to regular activities more quickly.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 50 条
  • [1] Pitfalls preventing bone union with EXOGEN Low-Intensity Pulsed Ultrasound
    Hughes, Luke D.
    Khudr, Jamal
    Gee, Edward
    Pillai, Anand
    [J]. SICOT-J, 2022, 8
  • [2] Complex fractures treated with EXOGEN, a Low Intensity Pulsed Ultrasound (LIPUS) therapy
    Boyle, S.
    Moore, J.
    Athar, M.
    Harty, J.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S158 - S158
  • [3] Low intensity pulsed ultrasound for fractures of the tibial shaft
    Griffin, X. L.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2016, 355
  • [4] Low intensity pulsed ultrasound for bone healing
    Schandelmaier S
    Kaushal A
    Lytvyn L
    [J]. 中华物理医学与康复杂志, 2017, 39 (05) : 396 - 396
  • [5] Low Intensity Pulsed Ultrasound for Bone Tissue Engineering
    McCarthy, Colleen
    Camci-Unal, Gulden
    [J]. MICROMACHINES, 2021, 12 (12)
  • [6] Pulsed electromagnetic fields and low intensity pulsed ultrasound in bone tissue
    Massari, Leo
    Caruso, Gaetano
    Sollazzo, Vincenzo
    Setti, Stefania
    [J]. CLINICAL CASES IN MINERAL AND BONE METABOLISM, 2009, 6 (02) : 149 - 154
  • [7] Preliminary study on the efficacy of low intensity pulsed ultrasound for osteoporosis
    Yamanaka, M
    Koji, A
    Tokita, A
    Ishijima, M
    Nozawa, M
    Kurosawa, H
    [J]. 4th International Symposium on Therapeutic Ultrasound, 2005, 754 : 107 - 109
  • [8] Low-intensity pulsed ultrasound in the treatment of tibial non-union
    Joshy, Suraj
    Gopalan, Suresh
    Deshmukh, S. C.
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2007, 17 (04): : 363 - 366
  • [9] Effects of Low Intensity Pulsed Ultrasound on Healing of Denervated Tibial Fracture in the Rabbit
    Sadraie, S. H.
    Kaka, Gh R.
    Mofid, M.
    Torkaman, G.
    Monfared, M. Jalali
    [J]. IRANIAN RED CRESCENT MEDICAL JOURNAL, 2011, 13 (01) : 34 - 41
  • [10] Low intensity pulsed ultrasound applied to bone of osteopenic rats
    Carvalho, DCL
    Cliquet, A
    [J]. OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S115 - S116