机构:
SW Res Inst, San Antonio, TX 78228 USASW Res Inst, San Antonio, TX 78228 USA
Lopushansky, RL
[1
]
Light, GM
论文数: 0引用数: 0
h-index: 0
机构:
SW Res Inst, San Antonio, TX 78228 USASW Res Inst, San Antonio, TX 78228 USA
Light, GM
[1
]
Gupta, NK
论文数: 0引用数: 0
h-index: 0
机构:
SW Res Inst, San Antonio, TX 78228 USASW Res Inst, San Antonio, TX 78228 USA
Gupta, NK
[1
]
机构:
[1] SW Res Inst, San Antonio, TX 78228 USA
来源:
NONDESTRUCTIVE EVALUATION OF UTILITIES AND PIPELINES II
|
1998年
/
3398卷
关键词:
D O I:
10.1117/12.302528
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
Detecting corrosion in insulated piping is a major industry problem and the consequences of not detecting corrosion can be costly. Digital radiography allows the user to examine insulated piping for internal and external corrosion defects while the piping remains in service. This technique minimizes the need for scaffolding, eliminates the need for insulation removal, and provides industry with a cost-effective means of examining its insulated piping systems.