Effect of varying frequency, intensity, and pulse duration of transcutaneous electrical nerve stimulation on primary hyperalgesia in inflamed rats

被引:101
|
作者
Gopalkrishnan, P
Sluka, KA
机构
[1] Univ Iowa, Coll Med, Phys Therapy Grad Program, Iowa City, IA 52242 USA
[2] Univ Iowa, Grad Program Neurosci, Iowa City, IA 52242 USA
来源
关键词
pain; inflammation; arthritis; hyperalgesia; analgesia; transcutaneous electric nerve stimulation; rehabilitation;
D O I
10.1053/apmr.2000.5576
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To examine the effect of varying frequency, intensity, and pulse duration of transcutaneous electrical nerve stimulation (TENS) on primary hyperalgesia (increased response to a noxious stimuli) to heat and mechanical stimuli induced by carrageenan paw inflammation in rats. Design: Inflammation was induced by injection of 3% carrageenan into the hindpaw. Two frequencies (high, 100Hz; low, 4Hz), 2 intensities (high, motor; low, sensory), and 2 pulse durations (100 mu sec, 250 mu sec) were applied for 20 minutes to the inflamed paw. The paw withdrawal latency (PWL) to radiant heat, threshold to mechanical stimuli, and spontaneous pain-related behaviors were measured before and 4 hours after induction of inflammation, after TENS, and at 8, 12, and 24 hours after inflammation. A 3-factor (frequency, intensity, pulse duration) repeated-measures (time) design was used to analyze the changes in PWL. Mechanical threshold and spontaneous pain-related behaviors were compared for frequency, intensity, and pulse duration with a Kruskal-Wallis analysis of variance. Results: For changes in PWL to heat, there was an effect for time (p = .0001) and frequency (p = .0001), but not for intensity (p = .45) or pulse duration (p = .21). For changes in mechanical threshold, there was also an effect for frequency (p = .007), but not for intensity (p = .055) or pulse duration (p = .058), after treatment with TENS. High-frequency TENS significantly reduced the primary hyperalgesia to heat and mechanical stimuli when compared with controls receiving no TENS or treatment with low-frequency TENS. High-frequency motor TENS also reduced spontaneous pain-related behaviors for 1 day after treatment. Conclusion: High-frequency TENS reduces primary hyperalgesia to heat and mechanical stimuli for up to 1 day after treatment. In contrast, low-frequency TENS is ineffective in reducing primary hyperalgesia. Varying intensity or pulse duration had no effect on the degree of antihyperalgesia produced by high-frequency TENS.
引用
收藏
页码:984 / 990
页数:7
相关论文
共 50 条
  • [31] The effect of chest wall transcutaneous electrical nerve stimulation on dyspnoea
    Torry, M
    Wilcock, A
    Cooper, BG
    Tattersfield, AE
    RESPIRATION PHYSIOLOGY, 1996, 104 (01): : 23 - 28
  • [32] Reduced analgesic effect of Transcutaneous Electrical Nerve Stimulation (TENS) in morphine-tolerant rats
    Goncalves, Heloisa H.
    Sabina, George S.
    Francischi, Janetti N.
    Resende, Marcos A.
    INFLAMMATION RESEARCH, 2005, 54 : S180 - S180
  • [33] Development of a method to maximize the transcutaneous electrical nerve stimulation intensity in women with fibromyalgia
    Vance, Carol G. T.
    Chimenti, Ruth L.
    Dailey, Dana L.
    Hadlandsmyth, Katherine
    Zimmerman, M. Bridget
    Geasland, Katharine M.
    Williams, Jonathan M.
    Merriwether, Ericka N.
    Munters, Li Alemo
    Rakel, Barbara A.
    Crofford, Leslie J.
    Sluka, Kathleen A.
    JOURNAL OF PAIN RESEARCH, 2018, 11 : 2269 - 2278
  • [34] The effect of transcutaneous nerve stimulation (TENS) on gastric electrical activity
    Furgala, A
    Thor, PJ
    Kolasinska-Kloch, W
    Krygowska-Wajs, A
    Kopp, B
    Laskiewicz, J
    JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2001, 52 (04): : 603 - 610
  • [35] Alteration of interferential current and transcutaneous electrical nerve stimulation frequency: Effects on nerve excitation
    Palmer, ST
    Martin, DJ
    Steedman, WM
    Ravey, J
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (09): : 1065 - 1071
  • [36] Modulation of sensation intensity in the lower limb via Transcutaneous Electrical Nerve Stimulation
    Demofonti, Andrea
    Scarpelli, Alessia
    Cordella, Francesca
    Zollo, Loredana
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6470 - 6473
  • [37] Effect of Modulated-Frequency and Modulated-Intensity Transcutaneous Electrical Nerve Stimulation After Abdominal Surgery A Randomized Controlled Trial
    Tokuda, Mitsunori
    Tabira, Kazuyuki
    Masuda, Takashi
    Nishiwada, Takashi
    Shomoto, Koji
    CLINICAL JOURNAL OF PAIN, 2014, 30 (07): : 565 - 570
  • [38] Varying frequency and pulse width duration during electrical stimulation of cervical sympathetic chain in Zucker Fat rats dramatically alters hemodynamics
    Hsieh, Yee-Hsee
    Zenebe, Woineshet J.
    Lewis, Stephen J.
    FASEB JOURNAL, 2019, 33
  • [39] Effects of cryotherapy, transcutaneous electrical stimulation and their combination on femoral nerve electrical activity in rats
    Santuzzi, C. H.
    Goncalves, W. L. S.
    Rocha, S. S.
    Castro, M. E. C.
    Gouvea, S. A.
    Abreu, G. R.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2008, 12 (06) : 441 - 446
  • [40] Effect of transcutaneous electrical nerve stimulation induced parotid stimulation on salivary flow
    Pattipati, Sreenivasulu
    Patil, Rajendra
    Kannan, N.
    Kumar, Praveen B.
    Shirisharani, G.
    Mohammed, Rezwana Begum
    CONTEMPORARY CLINICAL DENTISTRY, 2013, 4 (04) : 427 - 431