Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array

被引:6
|
作者
Delrue, Steven [1 ]
Aleshin, Vladislav [2 ]
Sorensen, Mikael [3 ,4 ]
De Lathauwer, Lieven [3 ,4 ]
机构
[1] KU Leuven Kulak, Wave Propagat & Signal Proc Res Grp, B-8500 Kortrijk, Belgium
[2] CNRS, UMR 8520, Inst Elect Microelect & Nanotechnol, Joint Int Lab LICS,LEMAC, F-59652 Villeneuve Dascq, France
[3] KU Leuven Kulak, Grp Sci Engn & Technol, B-8500 Kortrijk, Belgium
[4] Katholieke Univ Leuven, STADIUS, Dept Elect Engn ESAT, B-3001 Leuven Heverlee, Belgium
关键词
non-destructive testing; Nonlinear Air-Coupled Emission (NACE); crack localization; Direction Of Arrival (DOA); ultrasonic sensor array; ELASTIC-WAVE SPECTROSCOPY; DISCERN MATERIAL DAMAGE; ACOUSTIC NONLINEARITY; NEWS TECHNIQUES; CONTACT; IDENTIFICATION;
D O I
10.3390/s17040930
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The importance of Non-Destructive Testing (NDT) to check the integrity of materials in different fields of industry has increased significantly in recent years. Actually, industry demands NDT methods that allow fast (preferably non-contact) detection and localization of early-stage defects with easy-to-interpret results, so that even a non-expert field worker can carry out the testing. The main challenge is to combine as many of these requirements into one single technique. The concept of acoustic cameras, developed for low frequency NDT, meets most of the above-mentioned requirements. These cameras make use of an array of microphones to visualize noise sources by estimating the Direction Of Arrival (DOA) of the impinging sound waves. Until now, however, because of limitations in the frequency range and the lack of integrated nonlinear post-processing, acoustic camera systems have never been used for the localization of incipient damage. The goal of the current paper is to numerically investigate the capabilities of locating incipient damage by measuring the nonlinear airborne emission of the defect using a non-contact ultrasonic sensor array. We will consider a simple case of a sample with a single near-surface crack and prove that after efficient excitation of the defect sample, the nonlinear defect responses can be detected by a uniform linear sensor array. These responses are then used to determine the location of the defect by means of three different DOA algorithms. The results obtained in this study can be considered as a first step towards the development of a nonlinear ultrasonic camera system, comprising the ultrasonic sensor array as the hardware and nonlinear post-processing and source localization software.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] A focused, two dimensional, air-coupled ultrasonic array for non-contact generation
    Blum, F
    Jarzynski, J
    Jacobs, LJ
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 834 - 839
  • [32] Investigation on Characteristics of a MXenes-Based Air-Coupled Capacitive Ultrasonic Transducer Array
    Zhang, Qing
    Luo, Cizhu
    Wang, Ranxu
    Guo, Xinhua
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (23) : 28696 - 28705
  • [33] Application of air-coupled ultrasonic techniques using carbon/carbon composites
    Yang, In-Young
    Yang, Yong-June
    Park, Jun-Woo
    Lee, Kil-Sung
    Cho, Young-Tae
    Park, Je-Woong
    Hsu, David K.
    Im, Kwang-Hee
    [J]. ADVANCED WELDING AND MICRO JOINING / PACKAGING FOR THE 21ST CENTURY, 2008, 580-582 : 121 - +
  • [34] Real-Time 3-D Imaging Using an Air-Coupled Ultrasonic Phased-Array
    Allevato, Gianni
    Hinrichs, Jan
    Rutsch, Matthias
    Adler, Jan Philipp
    Jager, Axel
    Pesavento, Marius
    Kupnik, Mario
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 796 - 806
  • [35] Ultrasonic imaging using laser generation and piezoelectric air-coupled detection
    Wright, WMD
    Hutchins, DA
    Hayward, G
    Gachagan, A
    [J]. ULTRASONICS, 1996, 34 (2-5) : 405 - 409
  • [36] ULTRASONIC MEASUREMENTS IN POLYMERIC MATERIALS USING AIR-COUPLED CAPACITANCE TRANSDUCERS
    HUTCHINS, DA
    WRIGHT, WMD
    SCHINDEL, DW
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 96 (03): : 1634 - 1642
  • [37] Characterization of Water Absorption by CFRP Using Air-Coupled Ultrasonic Testing
    Lee, Joo-Min
    Lee, Joo-Sung
    Kim, Yong-Kwon
    Park, Ik-Keun
    [J]. JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2014, 34 (02) : 155 - 164
  • [38] Evaluation of sandwich materials using ultrasonic air-coupled scanning technique
    Borum, KK
    [J]. Sandwich Structures7: Advancing with Sandwich Structures and Materials, 2005, : 805 - 813
  • [39] Air-Coupled Ultrasonic Arrays for Assessment of Pipe Internal Geometry and Surface Condition
    Towlson, Alexander R. K.
    Croxford, Anthony J.
    Drinkwater, Bruce W.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (04) : 474 - 484
  • [40] Air-coupled piezoelectric micromachined ultrasonic transducers for surface stain detection and imaging
    Sun, Sheng
    Wang, Jianyuan
    Ning, Yuan
    Zhang, Menglun
    [J]. NANOTECHNOLOGY AND PRECISION ENGINEERING-NAMI JISHU YU JINGMI GONGCHENG, 2022, 5 (01):