A bayesian approach to the spectral F-Test: Application to auditory steady-state responses

被引:3
|
作者
Romao, Matheus [1 ,2 ]
Tierra-Criollo, Carlos Julio [3 ]
机构
[1] Univ Fed Minas Gerais, Grad Program Elect Engn, Av Antonio Carlos 6627, BR-31270901 Belo Horizonte, MG, Brazil
[2] Univ Fed Sao Joao del Rei, Campus Alto Paraopeba,Rod MG 443,KM 7, Ouro Branco, MG, Brazil
[3] Univ Fed Rio de Janeiro, Ctr Tecnol, COPPE, Av Horacio Macedo 2030,Bloco H,Sala 327, BR-36420000 Rio De Janeiro, RJ, Brazil
关键词
Bayesian detection; Spectral F-test; Objective Response Detection; Auditory Steady-state Responses; Evoked Potentials; EVOKED-POTENTIALS; STIMULATION; COHERENCE; EEG;
D O I
10.1016/j.cmpb.2019.105100
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Auditory steady-state responses (ASSRs) represent an objective method used in clinical practice to assess hearing thresholds. The steady-state nature of these signals allows response detection by means of statistical techniques in the frequency domain as spectral F-test. This objective response detection (ORD) compares the power of the response bin against the power of the neighboring frequency noise bins. Most ORD algorithms are based on the Neyman-Pearson approach to the hypothesis test provided that the likelihood ratio test is the most powerful test for a given significance level alpha (also called Type I error). On the other hand, the Bayesian approach allows the inclusion of prior information in the model and enables the updating of this information with posterior knowledge. This approach, however, has not been explored with respect to ORD techniques, thus enabling the exploration of new paradigms, which may contribute to this field of study, especially in terms of the time required for response detection. The aim of this study is to use the Bayesian approach in the implementation of the spectral F-test for application to ASSRs. Methods: Monte Carlo simulations were performed to evaluate Neyman-Pearson and Bayesian detectors' performances with the spectral F-test as a function of the signal-to-noise ratio. Then, the two detectors were applied to ASSR recordings of nine normal-hearing individuals subjected to amplitude-modulated tones of various intensities. Results: Both simulation and ASSR data analyses showed that among the scenarios analyzed, the most promising case was that in which the lowest possible values for the a priori probability were selected for the null hypothesis (H0), allowing detection at low signal-to-noise ratios. The worst performance occurred when the a priori probabilities for both hypotheses were equal. The ASSR data also showed that higher stimulus intensity led to better performance and faster detection due to improvements in the signal-tonoise ratio. Conclusions: The a priori probabilities can affect the Bayesian detector's performance, directly impacting the time needed to identify responses. The parallel behaviors observed between the performances of both approaches showed that the Bayesian detector can achieve its ideal performance at lower signal-to-noise ratios compared to the optimal performance of the Neyman-Pearson detector, reflecting the promising applicability of the Bayesian approach to evoked potentials. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] AUDITORY STEADY-STATE RESPONSES TO MULTIPLE SIMULTANEOUS STIMULI
    LINS, OG
    PICTON, TW
    EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1995, 96 (05): : 420 - 432
  • [22] Recording auditory steady-state responses in young infants
    John, MS
    Brown, DK
    Muir, PJ
    Picton, TW
    EAR AND HEARING, 2004, 25 (06): : 539 - 553
  • [23] Intracerebral sources of human auditory steady-state responses
    Herdman, AT
    Lins, O
    Van Roon, P
    Stapells, DR
    Scherg, M
    Picton, TW
    BRAIN TOPOGRAPHY, 2002, 15 (02) : 69 - 86
  • [24] Place specificity of multiple auditory steady-state responses
    Herdman, AT
    Picton, TW
    Stapells, DR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (04): : 1569 - 1582
  • [25] Auditory steady-state responses to exponential modulation envelopes
    John, MS
    Dimitrijevic, A
    Picton, TW
    EAR AND HEARING, 2002, 23 (02): : 106 - 117
  • [26] Efficient stimuli for evoking auditory steady-state responses
    John, MS
    Dimitrijevic, A
    Picton, TW
    EAR AND HEARING, 2003, 24 (05): : 406 - 423
  • [27] Sleep - wakefulness differences in auditory steady-state responses
    Gorska, U.
    Binder, M.
    JOURNAL OF SLEEP RESEARCH, 2016, 25 : 290 - 291
  • [28] Maturation of auditory steady-state responses in normal babies
    Rance, G
    Tomlin, D
    EAR AND HEARING, 2006, 27 (01): : 20 - 29
  • [29] The use of phase in the detection of auditory steady-state responses
    Picton, TW
    Dimitrijevic, A
    John, MS
    Van Roon, P
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (09) : 1698 - 1711
  • [30] Generation of auditory steady-state responses: linearity assessment
    Santarelli, R
    Conti, G
    SCANDINAVIAN AUDIOLOGY, 1999, 28 : 23 - 32