Potential influence of Gadolinium contrast on image segmentation in MR-based attenuation correction with Dixon sequences in whole-body 18F-FDG PET/MR

被引:10
|
作者
Ruhlmann, Verena [1 ]
Heusch, Philipp [2 ]
Kuehl, Hilmar [3 ]
Beiderwellen, Karsten [3 ]
Antoch, Gerald [2 ]
Forsting, Michael [3 ]
Bockisch, Andreas [1 ]
Buchbender, Christian [2 ]
Quick, Harald H. [4 ,5 ]
机构
[1] Univ Duisburg Essen, Univ Hosp Essen, Dept Nucl Med, Hufelandstr 55, D-45122 Essen, Germany
[2] Univ Dusseldorf, Fac Med, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
[3] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45147 Essen, Germany
[4] Univ Duisburg Essen, Erwin L Hahn Inst MR Imaging, D-45141 Essen, Germany
[5] Univ Hosp Essen, High Field & Hybrid MR Imaging, D-45147 Essen, Germany
关键词
PET/MR; Attenuation correction (AC); MR-based tissue segmentation; SUV; QUANTITATIVE-EVALUATION;
D O I
10.1007/s10334-015-0516-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the influence of Gadolinium contrast agent on image segmentation in magnetic resonance (MR)-based attenuation correction (AC) with four-segment dual-echo time Dixon-sequences in whole-body [18F]-fluorodeoxyglucose positron emission tomography (PET)/MR imaging, and to analyze the consecutive effect on standardized uptake value (SUV). Hybrid imaging with an integrated PET/MR system was performed in 30 oncological patients. AC was based on MR imaging with a Dixon sequence with subsequent automated image segmentation. AC maps (A mu maps) were acquired and reconstructed prior to (A mu map(-gd)) and after (A mu map(+gd)) Gd-contrast agent application. For quantification purposes, the SUV of organs and tumors based on both A mu maps were compared. Tissue classification based on A mu map(-gd) was correct in 29/30 patients; based on A mu map(+gd), the brain was falsely classified as fat in 12/30 patients with significant underestimation of SUV. In all cancerous lesions, tissue segmentation was correct. All concordant A mu maps(-gd/+gd) resulted in no significant difference in SUV. In PET/MR, Gd-contrast agent potentially influences fat/water separation in Dixon-sequences of the head with above-average false tissue segmentation and an associated underestimation of SUV. Thus, MR-based AC should be acquired prior to Gd-contrast agent application. Additionally, integrating the MR-based AC maps into the reading-routine in PET/MR is recommended to avoid interpretation errors in cases where tissue segmentation fails.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 50 条
  • [21] MR-based attenuation correction limits accuracy of quality control experiments on whole-body PET/MR systems
    Boellaard, R.
    Rausch, I.
    Beyer, T.
    Delso, G.
    Ziegler, S.
    Yaqub, M.
    Quick, H.
    Sattler, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S254 - S254
  • [22] Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging
    Aznar, M. C.
    Sersar, R.
    Saabye, J.
    Ladefoged, C. N.
    Andersen, F. L.
    Rasmussen, J. H.
    Lofgren, J.
    Beyer, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1177 - 1183
  • [23] Evaluation and automatic correction of metal-implant-induced artifacts in MR-based attenuation correction in whole-body PET/MR imaging
    Schramm, G.
    Maus, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2713 - 2726
  • [24] Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients
    Grueneisen, Johannes
    Sawicki, Lino Morris
    Wetter, Axel
    Kirchner, Julian
    Kinner, Sonja
    Aktas, Bahriye
    Forsting, Michael
    Ruhlmann, Verena
    Umutlu, Lale
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 89 : 14 - 19
  • [25] Quantitative Evaluation of 2 Scatter-Correction Techniques for 18F-FDG Brain PET/MRI in Regard to MR-Based Attenuation Correction
    Teuho, Jarmo
    Saunavaara, Virva
    Tolvanen, Tuula
    Tuokkola, Terhi
    Karlsson, Antti
    Tuisku, Jouni
    Teras, Mika
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (10) : 1691 - 1698
  • [26] MR-based attenuation correction in brain PET based on UTE sequences
    Jorge Cabello
    Stephan G Nekolla
    Sibylle I Ziegler
    EJNMMI Physics, 1 (Suppl 1)
  • [27] Influence and Compensation of Truncation Artifacts in MR-Based Attenuation Correction in PET/MR
    Schramm, G.
    Langner, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 2056 - 2063
  • [28] MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction
    Fei, Baowei
    Yang, Xiaofeng
    Nye, Jonathon A.
    Aarsvold, John N.
    Raghunath, Nivedita
    Cervo, Morgan
    Stark, Rebecca
    Meltzer, Carolyn C.
    Votaw, John R.
    MEDICAL PHYSICS, 2012, 39 (10) : 6443 - 6454
  • [29] 18F-FDG PET/MR versus MR Alone in Whole-Body Primary Staging and Restaging of Patients with Rectal Cancer: What Is the Benefit of PET?
    Li, Yan
    Mueller, Laura Isabel
    Neuhaus, Jan Peter
    Bertram, Stefanie
    Schaarschmidt, Benedikt Michael
    Demircioglu, Aydin
    Ludwig, Johannes Maximilian
    Kirchner, Julian
    Rischpler, Christoph
    Herrmann, Ken
    Catalano, Onofrio Antonio
    Umutlu, Lale
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (10) : 1 - 11
  • [30] [18F]-FDG SUV of reference regions in PET/MRI following standard MR-based attenuation correction
    Haidinger, I.
    Rausch, I.
    Mayerhoefer, M.
    Hartenbach, M.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S168 - S168