High Resolution 125I Pinhole SPECT Imaging of the Mouse Thyroid With the MediSPECT Small Animal CdTe Scanner

被引:6
|
作者
Mettivier, Giovanni [1 ,2 ]
Montesi, Maria Cristina [1 ,2 ]
Curion, Assunta Simona [1 ,2 ]
Lauria, Adele [1 ,2 ]
Marotta, Marcello [3 ]
Russo, Paolo [1 ,2 ]
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, I-80126 Naples, Italy
[2] INFN Sezione Napoli, I-80126 Naples, Italy
[3] Univ Naples Federico II, Dipartimento Med Clin & Sperimentale, I-80131 Naples, Italy
关键词
SYSTEM; SINGLE; TOMOGRAPHY; DETECTOR; DESIGN; PERFORMANCE;
D O I
10.1109/TNS.2010.2042815
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The first in vivo tomographic I-125 imaging of the mouse thyroid carried out with the new MediSPECT small animal SPECT scanner is presented. The scanner is based on a fine pitch CdTe semiconductor pixel detector (14 x 14 mm(2), 256 x 256 square pixel with a 55 mu m side) and equipped with a set of high resolution collimators. The collimation and detection units of the scanner are mounted on a gantry, rotating around a horizontal axis, along which is placed the small animal housing. In an in vivo test, the mouse was injected with a (NaI)-I-125 solution having a total activity of 31.8 MBq. The planar projections for SPECT reconstruction were acquired with a 300 mu m pinhole (magnification 1.47 and field of view of 9.6 x 9.6 mm(2)). The projections were captured in a step-and-shoot fashion and were processed with an Ordered Subsets-Expectation Maximization reconstruction algorithm in order to obtain the SPECT images. Several I-125 imaging tests have been made by using phantoms to assess the detector spatial resolution. The measured spatial resolution with a 300 mu m pinhole is about 0.5 mm in planar imaging and better than 1 mm in tomographic imaging.
引用
收藏
页码:1029 / 1037
页数:9
相关论文
共 50 条
  • [1] High Resolution 125I pinhole SPECT imaging of the mouse thyroid with the MediSPECT small animal CdTe scanner
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Lauria, Adele
    Russo, Paolo
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3065 - 3071
  • [2] Simultaneous 125I SPECT Imaging of small animals with pinhole and parallel collimation
    Welsh, RE
    Bradley, EL
    Cella, J
    Kross, B
    Majewski, S
    Popov, V
    Qian, JG
    Saha, MS
    Smith, K
    Smith, MF
    Weisenberger, AG
    Wojcik, R
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2300 - 2304
  • [3] HIGH-RESOLUTION PINHOLE SPECT FOR SMALL ANIMAL IMAGING
    ERLANDSSON, K
    IVANOVIC, M
    STRAND, SE
    SJOGREN, K
    WEBER, DA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P9 - P9
  • [4] PINHOLE SPECT - ULTRA-HIGH-RESOLUTION IMAGING FOR SMALL ANIMAL STUDIES
    WEBER, DA
    IVANOVIC, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (12) : 2287 - 2289
  • [5] High-resolution 125I small animal imaging with a coded aperture and a hybrid pixel detector
    Accorsi, Roberto
    Celentano, Luigi
    Laccetti, Paolo
    Lanza, Richard C.
    Marotta, Marcello
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Roberti, Giuseppe
    Russo, Paolo
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (01) : 481 - 490
  • [6] Design for a high-resolution small-animal SPECT system using pixellated Si(Li) detectors for in vivo 125I imaging
    Choong, WS
    Moses, WW
    Tindall, CS
    Luke, PN
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 174 - 180
  • [7] Design for a high-resolution small-animal SPECT system using pixellated Si(Li) detectors for In vivo 125I imaging
    Choong, WS
    Moses, WW
    Tindall, CS
    Luke, PN
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2315 - 2319
  • [8] Design and development of a high resolution animal SPECT scanner dedicated for rat and mouse imaging
    Sajedi, Salar
    Zeraatkar, Navid
    Moji, Vahideh
    Farahani, Mohammad Hossein
    Sarkar, Saeed
    Arabi, Hossein
    Teymoorian, Behnoosh
    Ghafarian, Pardis
    Rahmim, Arman
    Ay, Mohammad Reza
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 741 : 169 - 176
  • [9] Ultra high resolution pinhole SPECT for small animal study.
    Ogawa, K
    Kawade, T
    Nakamura, K
    Kubo, A
    Ichihara, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3122 - 3126
  • [10] High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging
    Izumi O. Umeda
    Kotaro Tani
    Keisuke Tsuda
    Masamitsu Kobayashi
    Mayumi Ogata
    Sadaaki Kimura
    Mitsuyoshi Yoshimoto
    Shuji Kojima
    Kunikazu Moribe
    Keiji Yamamoto
    Noriyuki Moriyama
    Hirofumi Fujii
    [J]. Annals of Nuclear Medicine, 2012, 26 : 67 - 76