Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners

被引:91
|
作者
Di Fiore, Adolfo [1 ]
Meneghello, Roberto [2 ,3 ]
Graiff, Lorenzo [1 ]
Savio, Gianpaolo [4 ,5 ,6 ]
Vigolo, Paolo [1 ]
Monaco, Carlo [7 ]
Stellini, Edoardo [8 ]
机构
[1] Univ Padua, Dept Neurosci, Dent Sch, Via Giustiniani 2, I-35100 Padua, Italy
[2] Univ Padua, Dept Management, Padua, Italy
[3] Univ Padua, Dept Engn, Padua, Italy
[4] Univ Padua, Dept Civil Engn, Padua, Italy
[5] Univ Padua, Dept Environm Engn, Padua, Italy
[6] Univ Padua, Dept Architectural Engn, Padua, Italy
[7] Univ Bologna, Div Prosthodont & Maxillofacial Rehabil, Dept Biomed & Neuromotor Sci DIBINEM, Alma Mater Studiorum, Bologna, Italy
[8] Univ Padua, Dent Sch, Padua, Italy
关键词
Digital impression; Dental implant; Accuracy; Intraoral scanner; Full arch; IMPRESSION TECHNIQUES; ACCURACY; PRECISION; FIT; RESTORATIONS; TECHNOLOGY;
D O I
10.1016/j.jpor.2019.04.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Compare the accuracy of intraoral digital impression in full-arch implant-supported fixed dental prosthesis acquired with eight different intraoral scanner (Ios). Methods: A polymethyl methacrylate acrylic model of an edentulous mandible with six scan-abutment was used as a master model and its dimensions measured with a coordinate measuring machine. Eight different Ios were used to generate digital impression: True Definition, Trios, Cerec Omnicam, 3D progress, CS3500, CS3600, Planmeca Emelard and Dental Wings. Fifteen digital impressions were made. A software called "Scan-abut" was developed to analyse and compare the digital impression with the master model, obtaining the scanning accuracy. The three-dimensional (3D) position and distance analysis were performed. Results: Mean value of the 3D position analysis showed that the True Definition (31 mu m +/- 8 mu m) and Trios (32 mu m +/- 5 mu m) have the best performance of the group. The Cerec Omnicam (71 mm +/- 55 mm), CS3600 (61 mu m +/- 14 mu m) have an average performance. The CS3500 (107 mu m +/- 28 mu m) and Planmeca Emelard (101 mu m +/- 38 mu m) present a middle-low performance, while the 3D progress (344 mu m +/- 121 mu m) and Dental Wings (148 mu m +/- 64 mu m) show the low performance. The 3D distance analysis showed a good linear relationship between the errors and scan-abutment distance only with the True Definition and CS3600. Conclusions: Not all scanners are suitable for digital impression in full-arch implant-supported fixed dental prosthesis and the weight of the output files is independent from the accuracy of the Ios. (C) 2019 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:396 / 403
页数:8
相关论文
共 50 条
  • [1] In vitro comparison of trueness of 10 intraoral scanners for implant-supported complete-arch fixed dental prostheses
    Bilmenoglu, Caglar
    Cilingir, Altug
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 755 - 760
  • [2] Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses
    Karl, Matthias
    Graef, Friedrich
    Schubinski, Peter
    Taylor, Thomas
    [J]. QUINTESSENCE INTERNATIONAL, 2012, 43 (07): : 555 - 562
  • [3] Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis
    Ashraf, Yasmine
    Abo El Fadl, Ahmad
    Hamdy, Amina
    Ebeid, Kamal
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (08) : 1257 - 1263
  • [4] In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses
    Costa, Vitoria
    Silva, Antonio Sergio
    Costa, Rosana
    Barreiros, Pedro
    Mendes, Joana
    Mendes, Jose Manuel
    [J]. DENTISTRY JOURNAL, 2022, 10 (06)
  • [5] Accuracy of different laboratory scanners for scanning of implant-supported full arch fixed prosthesis
    Ebeid, Kamal
    Nouh, Ingy
    Ashraf, Yasmine
    Cesar, Paulo F.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 843 - 848
  • [6] Intraoral scanning and dental photogrammetry for full-arch implant-supported prosthesis: A technique
    Clozza, Emanuele
    [J]. CLINICAL ADVANCES IN PERIODONTICS, 2023,
  • [7] Digital Impressions for Implant-Supported Fixed Dental Prostheses
    Lee S.J.
    Lee J.D.
    [J]. Current Oral Health Reports, 2017, 4 (2) : 136 - 141
  • [8] Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed prostheses: A prospective study
    Yan, Yuwei
    Lin, Xiao
    Yue, Xinxin
    Geng, Wei
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04): : 564 - 572
  • [9] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [10] Strain Behavior of Implant-Supported Full-Arch Fixed Dental Prostheses Supported by Four or Five Implants
    Sbardelotto, Cristian
    Lapria Faria, Adriana Claudia
    Tiossi, Rodrigo
    Ribeiro, Ricardo Faria
    Silveira Rodrigues, Renata Cristina
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 153 - 158