Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed prostheses: A prospective study

被引:9
|
作者
Yan, Yuwei [1 ]
Lin, Xiao [1 ]
Yue, Xinxin [1 ]
Geng, Wei [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Stomatol Hosp, Dept Dent Implant Ctr, Sch Stomatol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Stomatol Hosp, Dept Dent Implant Ctr, Sch Stomatol, 4 Tian Tan Xi Li, Beijing 100050, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 04期
基金
中国国家自然科学基金;
关键词
CONVENTIONAL IMPRESSIONS; MULTIPLE IMPLANTS; PHOTOGRAMMETRY; PRECISION; REHABILITATION; FIT; POSITIONS; MISFIT;
D O I
10.1016/j.prosdent.2022.03.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Conventional impression techniques for complete arch implant-supported prostheses are technique-sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer an alternative to conventional impression making. Purpose. The purpose of this prospective study was to compare the accuracy of IOS and SPG for complete arch implant scans and to evaluate the passive fit of frameworks fabricated with SPG.Material and methods. Laboratory scanning of gypsum casts, SPG, and IOS were performed for all participants. The data regarding the abutment platform were superimposed to calculate the 3D deviation of SPG and IOS compared with that of laboratory scanning as an evaluation of accuracy. The effect of implant position and number on accuracy was analyzed. The more accurate technique between SPG and IOS was used to fabricate the titanium frameworks, as was laboratory scanning. The passive fit of the frameworks was assessed by clinical examination, the Sheffield test, and panoramic radiography.Results. Seventeen participants (21 arches, 120 implants) were included. The accuracy of SPG ranged from 2.70 mu m to 92.80 mu m, with a median (Q1, Q3) of 17.00 (11.68, 22.50) mu m, which was significantly more accurate than that of IOS, ranging from 21.30 mu m to 815.60 mu m, with a median (Q1, Q3) of 48.95 (34.78, 75.88) mu m. No significant correlation was found between position or number of implants and 3D deviation in the SPG group. A weak positive correlation was found between implant number and 3D deviation in the IOS group. SPG and laboratory scanning were used to fabricate titanium frameworks. The passive fit between the frameworks and abutment platforms was confirmed.Conclusions. SPG, which was not affected by position or number of implants, was more accurate than IOS and comparable with laboratory scanning. The frameworks fabricated based on SPG and laboratory scanning were comparable in their passive fit. The SPG technique may be an alternative to laboratory scanning for complete arch implant scans. (J Prosthet Dent 2023;130:564-72)
引用
收藏
页码:564 / 572
页数:9
相关论文
共 50 条
  • [1] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104
  • [2] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [3] Accuracy of traditional open-tray impression, stereophotogrammetry, and intraoral scanning with prefabricated aids for implant-supported complete arch prostheses with different implant distributions: An in vitro study
    Liu, Min
    Fu, Xiao-Jiao
    Lai, Hong-Chang
    Shi, Jun-Yu
    Liu, Bei-Lei
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03):
  • [4] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [5] Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners
    Di Fiore, Adolfo
    Meneghello, Roberto
    Graiff, Lorenzo
    Savio, Gianpaolo
    Vigolo, Paolo
    Monaco, Carlo
    Stellini, Edoardo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 396 - 403
  • [6] Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses
    Karl, Matthias
    Graef, Friedrich
    Schubinski, Peter
    Taylor, Thomas
    QUINTESSENCE INTERNATIONAL, 2012, 43 (07): : 555 - 562
  • [7] Digital scanning for implant-supported fixed complete-arch dental prostheses for patients with epidermolysis bullosa: A case series evaluation
    Agustin-Panadero, Ruben
    Serra-Pastor, Blanca
    Penarrocha-Oltra, David
    Ferreiroa, Alberto
    Penarrocha-Diago, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (04): : 364 - 370
  • [8] Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis
    Ashraf, Yasmine
    Abo El Fadl, Ahmad
    Hamdy, Amina
    Ebeid, Kamal
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (08) : 1257 - 1263
  • [9] Accuracy of different digital acquisition methods in complete arch implant-supported prostheses: An in vitro study
    Pinto, Ricardo J.
    Casado, Sara A.
    Chmielewski, Krzysztof
    Carames, Joao M.
    Marques, Duarte S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 172 - 177
  • [10] Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study
    Tohme, Hani
    Lawand, Ghida
    Chmielewska, Maja
    Makhzoume, Joseph
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (02): : 354 - 362