Calibration and performances of a multichannel DAQ system for Silicon Photomultiplier (SiPM) matrices in PET applications.

被引:0
|
作者
Marcatili, Sara [1 ,2 ]
Bisogni, Maria G. [1 ,2 ]
Collazuol, Gianmaria [2 ]
Llosa, Gabriela [1 ]
Magazzti, Guido [2 ]
Morsani, Fabio [2 ]
Del Guerra, Alberto [1 ,2 ]
机构
[1] Univ Pisa, Dept Phys, Lgo Pontecorvo 3, I-56127 Pisa, Italy
[2] INFN, Sez Pisa, I-56127 Pisa, Italy
关键词
D O I
10.1109/NSSMIC.2009.5402270
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of large area multipixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Digital Acquisition system (DAQ). At the University of Pisa and INFN Pisa we constructed a DAQ board for the read-out of 2 16-pixel SiPM matrices in time coincidence for Positron Emission Tomography (PET) applications. Our goal is the assessment of a small animal PET prototype consisting of two detector heads based on LYSO continuos crystal read by SiPM matrices. The proof of principle is based on 16 pixel detectors, but the whole system has been conceived to be easily scalable to a higher number of channels. Here we present the full characterization of the electronics and first measurements with the two detector heads.
引用
收藏
页码:2319 / +
页数:2
相关论文
共 45 条
  • [41] Assessment of the systolic left ventricular function from gated [Rb-82] Silicon-Photomultiplier (SiPM) PET/CT: A head-to-head comparison against two- dimensional planimetry transthoracic echocardiography
    Kamani, C.
    Ducchini, M.
    Dietz, M.
    Monney, P.
    Prior, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S137 - S137
  • [42] Study on the electric performances of planar inductor with Fe-system magnetic flake composite integrated for SiP DC-to-DC converter applications.
    Endo, Y.
    Sato, H.
    Miyazaki, T.
    Yamaguchi, M.
    Kamada, H.
    Takahashi, M.
    Sakamoto, M.
    Maita, S.
    Kato, N.
    Yorozu, Y.
    Yasui, T.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [43] Phantom and clinical assessment of small pulmonary nodules using Q.Clear reconstruction on a silicon-photomultiplier-based time-of-flight PET/CT system
    Wu, Zhifang
    Guo, Binwei
    Huang, Bin
    Hao, Xinzhong
    Wu, Ping
    Zhao, Bin
    Qin, Zhixing
    Xie, Jun
    Li, Sijin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [44] Phantom and clinical assessment of small pulmonary nodules using Q.Clear reconstruction on a silicon-photomultiplier-based time-of-flight PET/CT system
    Zhifang Wu
    Binwei Guo
    Bin Huang
    Xinzhong Hao
    Ping Wu
    Bin Zhao
    Zhixing Qin
    Jun Xie
    Sijin Li
    Scientific Reports, 11
  • [45] An evolutionary algorithm in the optimal design of single-input (SIMO) system of dynamic PET images with applications to input-multichannel parameter estimation.
    Shoghi-jadid, K
    Landaw, EM
    Huang, SC
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 264P - 264P