摘要
P>Aims We assessed an extended interruption of subcutaneous insulin delivery during overnight closed-loop glucose control in children and adolescents with Type 1 diabetes (T1D). Methods In seven young subjects with T1D [age 14.2 +/- 2.1 years, diabetes duration 6.9 +/- 4.0 years, glycated haemoglobin (HbA(1c)) 8.0 +/- 1.5%, body mass index (BMI) 21.4 +/- 4.0 kg/m2, total daily insulin dose 0.9 +/- 0.2 units/kg/day; mean +/- sd) participating in overnight closed-loop glucose control studies, insulin delivery was interrupted for at least 90 min on the basis of predicted hypoglycaemia, low prevailing glucose levels or a too-steep decline in glucose levels. Results Insulin delivery was interrupted for 165 (105, 210) min [median, interquartile range (IQR)]. Plasma glucose was 6.2 +/- 3.2 mmol/l at the time of interruption and 5.5 +/- 2.0 mmol/l 105 min later (P = 0.15, paired t-test). Plasma glucose declined during the first hour of the interruption at a rate of 0.02 +/- 0.03 mmol/l per min and reached a nadir of 5.2 +/- 2.7 mmol/l; 105 min after the interruption, plasma glucose was increasing at a rate of 0.01 +/- 0.03 mmol/l per min. When insulin delivery restarted, plasma glucose was 6.4 +/- 2.2 mmol/l and peaked at 7.9 +/- 2.1 mmol/l in 60 min (P = 0.01). Physiological levels of plasma insulin were measured throughout with a nadir of 119 +/- 78 pmol/l. Conclusions A prolonged interruption of insulin delivery during overnight closed-loop glucose control to prevent hypoglycaemia was not associated with an increased risk of hyperglycaemia in young people with T1D.
引用
收藏
页码:480 / 484
页数:5
相关论文
共 50 条
  • [21] Closed-Loop Insulin Delivery in Type 1 Diabetes
    Thabit, Hood
    Hovorka, Roman
    ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2012, 41 (01) : 105 - +
  • [22] NO EFFECT OF AGE OF INSULIN CATHETER ON OVERNIGHT CLOSED-LOOP GLUCOSE CONTROL IN HOME SETTINGS
    Nodale, M.
    Elleri, D.
    Allen, J.
    El-Khairi, R.
    Murphy, H.
    Wilinska, M. E.
    Acerini, C.
    Dunger, D.
    Hovorka, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A42 - A43
  • [23] A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
    Breton, Marc D.
    Kanapka, Lauren G.
    Beck, Roy W.
    Ekhlaspour, Laya
    Forlenza, Gregory P.
    Cengiz, Eda
    Schoelwer, Melissa
    Ruedy, Katrina J.
    Jost, Emily
    Carria, Lori
    Emory, Emma
    Hsu, Liana J.
    Oliveri, Mary
    Kollman, Craig C.
    Dokken, Betsy B.
    Weinzimer, Stuart A.
    DeBoer, Mark D.
    Buckingham, Bruce A.
    Chernavvsky, Daniel
    Wadwa, R. Paul
    NEW ENGLAND JOURNAL OF MEDICINE, 2020, 383 (09): : 836 - 845
  • [24] Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes
    Hsu, Nin-Chieh
    Hsu, Chia-Hao
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 388 (23): : 2205 - 2206
  • [25] Overnight Closed-Loop Control Improves Glycemic Control in a Multicenter Study of Adults With Type 1 Diabetes
    Brown, Sue A.
    Breton, Marc D.
    Anderson, Stacey M.
    Kollar, Laura
    Keith-Hynes, Patrick
    Levy, Carol J.
    Lam, David W.
    Levister, Camilla
    Baysal, Nihat
    Kudva, Yogish C.
    Basu, Ananda
    Dadlani, Vikash
    Hinshaw, Ling
    McCrady-Spitzer, Shelly
    Bruttomesso, Daniela
    Visentin, Roberto
    Galasso, Silvia
    del Favero, Simone
    Leal, Yenny
    Boscari, Federico
    Avogaro, Angelo
    Cobelli, Claudio
    Kovatchev, Boris P.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2017, 102 (10): : 3674 - 3682
  • [26] Overnight closed-loop insulin delivery at home in pregnant women with Type 1 diabetes: a feasibility study
    Stewart, Z. A.
    Wilinska, M.
    Hartnell, S.
    Simmons, D.
    Temple, R.
    Stanley, K.
    Rayman, G.
    Hovorka, R.
    Murphy, H. R.
    DIABETIC MEDICINE, 2016, 33 : 13 - 13
  • [27] Model-Based Closed-Loop Glucose Control in Type 1 Diabetes
    Schmidt, Signe
    Boiroux, Dimitri
    Duun-Henriksen, Anne Katrine
    Jorgensen, John Bagterp
    Poulsen, Niels Kjolstad
    Madsen, Henrik
    Skyggebjerg, Ole
    Madsbad, Sten
    Norgaard, Kirsten
    DIABETES, 2013, 62 : A247 - A247
  • [28] Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes
    Stewart, Zoe A.
    Wilinska, Malgorzata E.
    Hartnell, Sara
    Temple, Rosemary C.
    Rayman, Gerry
    Stanley, Katharine P.
    Simmons, David
    Law, Graham R.
    Scott, Eleanor M.
    Hovorka, Roman
    Murphy, Helen R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (07): : 644 - 654
  • [29] Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes
    Murphy, Helen R.
    Eller, Daniela
    Allen, Janet M.
    Harris, Julie
    Simmons, David
    Rayman, Gerry
    Temple, Rosemary
    Dunger, David B.
    Haidar, Ahmad
    Nodale, Marianna
    Wilinska, Malgorzata E.
    Hovorka, Roman
    DIABETES CARE, 2011, 34 (02) : 406 - 411
  • [30] Enlarging the loop: closed-loop insulin delivery for type 1 diabetes
    Galderisi, Alfonso
    Sherr, Jennifer L.
    LANCET, 2018, 392 (10155): : 1282 - 1284