No Useful Field Expansion with Full-field Prisms

被引:8
|
作者
Jung, Jae-Hyun [1 ]
Peli, Eli [1 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear, Schepens Eye Res Inst, Dept Ophthalmol, Boston, MA 02115 USA
关键词
SPECTACLE FRAMES; MONOCULAR VISION;
D O I
10.1097/OPX.0000000000001271
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: Full-field prisms that fill the entire spectacle eye wire have been considered as field expansion devices for homonymous hemianopia (HH) and acquired monocular vision (AMV). Although the full-field prism is used for addressing binocular dysfunction and for prism adaptation training after brain injury as treatment for spatial hemineglect, we show that the full-field prism for field expansion does not effectively expand the visual field in either HH or AMV. PURPOSE: Full-field prisms may shift a portion of the blind side to the residual seeing side. However, foveal fixation on an object of interest through a full-field prism requires head and/or eye rotation away from the blind side, thus negating the shift of the field toward the blind side. METHODS: We fit meniscus and flat full-field 7 Delta and 12 Delta yoked prisms and conducted Goldmann perimetry in HH and AMV. We compared the perimetry results with ray tracing calculations. RESULTS: The rated prism power was in effect at the primary position of gaze for all prisms, and the meniscus prisms maintained almost constant power at all eccentricities. To fixate on the perimetry target, the subjects needed to turn their head and/or eyes away from the blind side, which negated the field shift into the blind side. In HH, there was no difference in the perimetry results on the blind side with any of the prisms. In AMV, the lower nasal field of view was slightly shifted into the blind side with the flat prisms, but not with the meniscus prisms. CONCLUSIONS: Full-field prisms are not an effective field expansion device owing to the inevitable fixation shift. There is potential for a small field shift with the flat full-field prism in AMV, but such lenses cannot incorporate refractive correction. Furthermore, in considering the apical scotoma, the shift provides a mere field substitution at best. Copyright (C) 2018 American Academy of Optometry
引用
收藏
页码:805 / 813
页数:9
相关论文
共 50 条
  • [1] No useful field expansion for hemianopia or acquire monocular vision with full-field prisms
    Jung, Jae-Hyun
    Peli, Eli
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [2] Constitutive behaviour of masonry prisms using a full-field measurement technique
    Bello, Ismail
    Wardeh, George
    Gonzalez-Fonteboa, Belen
    Martinez-Abella, Fernando
    Ghorbel, Elhem
    [J]. STRUCTURES, 2022, 46 : 1726 - 1736
  • [3] FULL-FIELD PRISMS FOR HEMI-FIELD VISUAL IMPAIRMENTS FOLLOWING STROKE - A CONTROLLED TRIAL
    BAINBRIDGE, W
    REDING, M
    [J]. NEUROLOGY, 1994, 44 (04) : A312 - A313
  • [4] Multiplexing Prisms for Field Expansion
    Peli, Eli
    Jung, Jae-Hyun
    [J]. OPTOMETRY AND VISION SCIENCE, 2017, 94 (08) : 817 - 829
  • [5] Full-field OCT
    Dubois, Arnaud
    Boccara, Claude
    [J]. M S-MEDECINE SCIENCES, 2006, 22 (10): : 859 - 864
  • [6] FIELD EXPANSION BY USE OF BINOCULAR FULL-FIELD REVERSED 1.3X TELESCOPIC SPECTACLES
    MEHR, EB
    QUILLMAN, RD
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1979, 56 (07): : 446 - 450
  • [7] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [8] An improved full-field compensator
    Hariharan, P
    Ciddor, PE
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (08) : 936 - 937
  • [9] Paraxial full-field cloaking
    Choi, Joseph S.
    Howell, John C.
    [J]. OPTICS EXPRESS, 2015, 23 (12): : 15857 - 15862
  • [10] A full-field optical crazimeter
    Kumar, Raj
    Varshney, Tushar
    Yadav, Tarun
    Dwivedi, Gaurav
    Barve, S. K.
    Singh, Omendra
    [J]. JOURNAL OF OPTICS, 2021, 23 (12)