Water compatible stir-bar devices imprinted with underivatised glyphosate for selective sample clean-up

被引:27
|
作者
Gomez-Caballero, Alberto [1 ]
Diaz-Diaz, Goretti [1 ]
Bengoetxea, Olatz [1 ]
Quintela, Amaia [1 ]
Unceta, Nora [1 ]
Aranzazu Goicolea, M. [1 ]
Barrio, Ramon J. [1 ]
机构
[1] Univ Basque Country, UPV EHU, Fac Pharm, Dept Analyt Chem, Vitoria 01006, Spain
关键词
Water compatible MIP; SBSE; Glyphosate; Soils; Natural waters; SOLID-PHASE EXTRACTION; AMINOMETHYL-PHOSPHONIC ACID; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; SPECTROMETRY; HERBICIDES; POLYMER; GLUFOSINATE; IMMUNOASSAY; METABOLITES;
D O I
10.1016/j.chroma.2016.05.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the development of stir bars with a new MIP based coating, for the selective sorptive extraction of the herbicide glyphosate (GLYP). Molecular imprinting of the polymer has directly been carried out employing underivatised GLYP as the template molecule. Due to the poor solubility of the target compound in organic solvents, the MIP methodology has been optimised for rebinding in aqueous media, being the synthesis and the rebinding steps carried out in water:methanol mixtures and pure aqueous media. The coating has been developed by radical polymerisation initiated by UV energy, using N-allylthiourea and 2-dimethyl aminoethyl methacrylate as functional monomers and ethylene glycol dimethacrylate as the cross-linker. Mechanical stability of the coating has been improved using 1,3-divinyltetramethyldisiloxane in the polymerisation mixture. Under the optimised conditions, the MIP has demonstrated excellent selectivity for the target compound in the presence of structural analogues, including its major metabolites. The applicability of the proposed method to real matrices has also been assessed using river water and soil samples. Registered mean recoveries ranged from 90.6 to 97.3% and RSD values were below 5% in all cases, what confirmed the suitability of the described methodology for the selective extraction and quantification of GLYP. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 38 条
  • [21] Development of molecularly imprinted poly(methacrylic acid)/silica for clean-up and selective extraction of cholesterol in milk prior to analysis by HPLC-UV
    Clausen, D. N.
    Visentainer, J. V.
    Tarley, C. R. T.
    ANALYST, 2014, 139 (19) : 5021 - 5027
  • [22] Specific recognition of cationic paraquat in environmental water and vegetable samples by molecularly imprinted stir-bar sorptive extraction based on monohydroxylcucurbit[7]uril-paraquat inclusion complex
    Yao, Jianmei
    Zhang, Lingxue
    Ran, Jinfeng
    Wang, Shasha
    Dong, Nan
    MICROCHIMICA ACTA, 2020, 187 (10)
  • [23] Development of selective preconcentration/clean-up method for imidazolinone herbicides determination in natural water and rice samples by HPLC-PAD using an imazethapyr imprinted poly(vinylimidazole-TRIM)
    Teixeira Tarley, Cesar Ricardo
    Cajamarca Suquila, Fabio Antonio
    Casarin, Juliana
    Goncalves Junior, Affonso Celso
    Segatelli, Mariana Gava
    FOOD CHEMISTRY, 2021, 334
  • [24] Highly selective magnetic dual-template molecularly imprinted polymer for simultaneous removal and clean-up of nitenpyram and imidacloprid from light and dark honey
    Abdulhussein, Ahmed Qasim
    Abu Bakar, Nor Kartini
    Kafeenah, Husam I. S.
    Jamil, Arniza Khairani Mohd
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 103 (18) : 7116 - 7134
  • [25] Hollow porous molecularly imprinted polymer for highly selective clean-up followed by influential preconcentration of ultra-trace glibenclamide from bio-fluid
    Ostovan, Abbas
    Ghaedi, Mehrorang
    Arabi, Maryam
    Asfaram, Arash
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1520 : 65 - 74
  • [26] Highly selective fenuron-imprinted polymer with a homogeneous binding site distribution prepared by precipitation polymerisation and its application to the clean-up of fenuron in plant samples
    Tamayo, FG
    Casillas, JL
    Martin-Esteban, A
    ANALYTICA CHIMICA ACTA, 2003, 482 (02) : 165 - 173
  • [27] Magnet-assisted selective oil removal from water in non-open channel and continuous oil spills clean-up
    Xia, Lei
    Chen, Faze
    Cai, Zexin
    Chao, Jiaqi
    Tian, Yanling
    Zhang, Dawei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 282
  • [28] One-step selective electrokinetic removal of inorganic anions from small volumes and its application as sample clean-up for mass spectrometric techniques
    Tubaon, Ria Marni
    Haddad, Paul R.
    Quirino, Joselito P.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1488 : 134 - 139
  • [29] Performance of restricted access copper-imprinted poly(allylthiourea) in an on-line preconcentration and sample clean-up FIA-FAAS system for copper determination in milk samples
    Cajamarca Suquila, Fabio Antonio
    Teixeira Tarley, Cesar Ricardo
    TALANTA, 2019, 202 : 460 - 468
  • [30] Fast clean-up and selective enrichment of florfenicol in milk by restricted access media molecularly imprinted magnetic microspheres based on surface-initiated photoiniferter-mediated polymerization
    Lv, Yun-Kai
    Zhang, Jing
    Li, Meng-Zhe
    Zhou, Shao-Dan
    Ren, Xing-Hui
    Wang, Jing
    ANALYTICAL METHODS, 2016, 8 (19) : 3982 - 3989