Artifacts in 3D rotational angiography. An experimental study

被引:4
|
作者
Hagen, G [1 ]
Lindgren, PG
Jangland, L
Magnusson, P
Magnusson, A
机构
[1] Sykehuset Ostfold Moss, Dept Radiol, NO-1530 Moss, Norway
[2] Uppsala Univ, Dept Oncol Radiol & Clin Immunol, Sect Radiol, Uppsala, Sweden
[3] Univ Uppsala, Akad Sjukhuset, Dept Med Phys, Uppsala, Sweden
关键词
angiography; technology; artifacts; beam hardening; sampling; imaging; three-dimensional; radiography; computer-assisted; kidney; transplantation;
D O I
10.1080/02841850510012571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate artifacts in three-dimensional rotational angiography (3D-RA) in an experimental model and to evaluate which parameters influence their distribution. Material and Methods: 3D-RA was carried out in a circular vessel phantom filled with contrast medium. Two different rotational angulations were used: 160degrees causing 64 images and 180degrees causing 90 or 120 images. The images were transferred to one workstation for reconstruction of axial slices and then to another workstation for 3D reconstructions. The 3D reconstructions were compared with standardized threshold settings. Results: The artifacts occurred where the vessel had a longer path parallel to the rotation plane and became increasingly pronounced when the threshold level was raised. The artifacts decreased in size when rotation angle and number of projections were increased. Conclusion: The quality of the 3D reconstructions from RA was degraded by beam-hardening and sampling artifacts. The sampling artifacts were diminished by increasing both the rotation angle and the number of projections. The distortions in the 3D reconstructions caused by beam-hardening remain to be resolved. The threshold values also had a considerable influence on the 3D reconstructions.
引用
收藏
页码:32 / 36
页数:5
相关论文
共 50 条
  • [21] Pre-embolization study of ruptured cerebral aneurysm with rotational and 3D reconstruction angiography
    Castaño-Duque, CH
    Guardia-Mas, E
    de Juan-Delago, M
    Ruscalleda-Nadal, J
    DEVELOPMENTS IN NEUROSCIENCE, PROCEEDINGS, 2002, 1247 : 39 - 52
  • [22] Cerebral aneurysm hemodynamics modeling from 3D rotational angiography
    Cebral, JR
    Castro, MA
    Burgess, JE
    Putman, CM
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 944 - 947
  • [23] Simultaneous bilateral internal carotid artery 3D rotational angiography
    Song, JK
    Niimi, Y
    Brisman, JL
    Berenstein, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (10) : 1787 - 1789
  • [24] Compressed Sensing Based 3D Tomographic Reconstruction for Rotational Angiography
    Langet, Helene
    Riddell, Cyril
    Trousset, Yves
    Tenenhaus, Arthur
    Lahalle, Elisabeth
    Fleury, Gilles
    Paragios, Nikos
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 97 - +
  • [25] 3D Rotational Angiography After Non-Traumatic SAH
    Ringelstein, A.
    Mueller, O.
    Moenninghoff, C.
    Hahnemann, M. L.
    Sure, U.
    Forsting, M.
    Schlamann, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (07): : 675 - 679
  • [26] 3D Quantitative Evaluation of Atherosclerotic Plaque Based on Rotational Angiography
    Chien, A.
    Sayre, J.
    Dong, B.
    Ye, J.
    Vinuela, F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1249 - 1254
  • [27] Radiological evaluation of middle meningeal artery by 3D rotational angiography
    Sari, Lutfullah
    Yilmaz, Temel Fatih
    Oz, Ibrahim Ilker
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [28] CT—3D rotational angiography automatic registration: A sensitivity analysis
    J. Stancanello
    C. Cavedon
    P. Francescon
    P. Cerveri
    G. Ferrigno
    F. Causin
    F. Colombo
    Medical and Biological Engineering and Computing, 2005, 43 : 667 - 671
  • [29] Rotational 3D angiography in stereotactic radiosurgery of cerebral arteriovenous malformations
    Causin, F
    Castellan, L
    Iannucci, G
    Pinna, V
    Cavedon, C
    Colombo, E
    Casentini, L
    Perini, S
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 : 293 - 293
  • [30] Improved visualization of 3D data sets on the example of 3D-rotational angiography
    Koppe, R
    Klotz, E
    de Beek, JO
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1014 - 1014