Using plastic track detectors to solve radiation safety problems at nuclear reactor facilities

被引:2
|
作者
Diakov, AA [1 ]
Rostovtsev, VY
Perekhojeva, TN
Zlokazova, EI
Betenekov, ND
Ipatova, EG
Antropov, OV
Denisov, EI
机构
[1] Sverdlovsk Branch Res & Dev, Inst Power Engn, Zarechny 624051, Sverdlovsk, Russia
[2] Ural State Tech Univ, UGTU, UPI, Ekaterinburg, Russia
关键词
liquid radioactive waste; coolant; uranium and plutonium microconcentrations; plastic track detectors; thin-layer inorganic sorbents; radiochemical concentrating;
D O I
10.1016/S1350-4487(97)00100-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Three options of the method to determine microconcentrations of fissile materials in water solutions are developed. They utilize plastic track detectors to measure concentrations. The options are as follows a "wet" method, "thin-layer inorganic sorbents-plastic track detectors", and a method of selective extraction and coprecipitation. These methods are used to check up fuel cladding integrity at the research reactor IVV-2M and liquid radioactive waste contamination by uranium and plutonium at the Beloyarskaya Nuclear Power Plant (BNPP).
引用
收藏
页码:357 / 361
页数:5
相关论文
共 50 条
  • [21] Fluorescent nuclear track detectors for alpha radiation microdosimetry
    J. J. M. Kouwenberg
    H. T. Wolterbeek
    A. G. Denkova
    A. J. J. Bos
    Radiation Oncology, 13
  • [22] Nuclear track detectors for environmental studies and radiation monitoring
    Manzoor, S.
    Balestra, S.
    Cozzi, M.
    Errico, M.
    Giacomelli, G.
    Giorgini, M.
    Kumar, A.
    Margiotta, A.
    Medinaceli, E.
    Patrizii, L.
    Popa, V.
    Qureshi, I. E.
    Togo, V.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 92 - 96
  • [23] THE APPLICATIONS OF NUCLEAR TRACK DETECTORS IN TRANSURANIC CONTAMINATION PROBLEMS
    ESPINOSA, G
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 347 - 350
  • [24] ON THE USE OF THERMO-LUMINESCENCE AND SOLID-STATE NUCLEAR TRACK DETECTORS IN NUCLEAR SAFETY FOR RADIATION PROTECTION
    GOMAA, MA
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1984, 9 (01): : 11 - 17
  • [25] Cosmic radiation monitoring at low-Earth orbit by means of thermoluminescence and plastic nuclear track detectors
    Ambrozova, Iva
    Brabcova, Katerina Pachnerova
    Kubancak, Jan
    Slegl, Jakub
    Tolochek, Raisa V.
    Ivanova, Olga A.
    Shurshakov, Vyacheslav A.
    RADIATION MEASUREMENTS, 2017, 106 : 262 - 266
  • [26] Nuclear reactor power monitoring using silicon carbide semiconductor radiation detectors
    Ruddy, FH
    Dulloo, AR
    Seidel, JG
    Hantz, FW
    Grobmyer, LR
    NUCLEAR TECHNOLOGY, 2002, 140 (02) : 198 - 208
  • [27] SEARCH FOR ANOMALONS IN PROJECTILE FRAGMENTS OF AR-40 USING PLASTIC NUCLEAR TRACK DETECTORS
    HEINRICH, W
    DRECHSEL, H
    TRAKOWSKI, W
    BEER, J
    BRECHTMANN, C
    DREUTE, J
    SONNTAG, S
    PHYSICAL REVIEW LETTERS, 1984, 52 (16) : 1401 - 1404
  • [28] CALIBRATION OF PLASTIC NUCLEAR TRACK DETECTORS FOR IDENTIFICATION OF HEAVY CHARGED NUCLEI USING FISSION FRAGMENTS
    ENDO, K
    DOKE, T
    NUCLEAR INSTRUMENTS & METHODS, 1973, 111 (01): : 29 - 37
  • [29] HZE dosimetry in space using plastic track detectors
    Institut für Experimentelle und Angewandte Physik, Universität Kiel, Olshausenstr.40/60, 24118 Kiel, Germany
    不详
    Radiat. Meas., 1 (573-578):
  • [30] HZE dosimetry in space using plastic track detectors
    Kopp, J
    Beaujean, R
    Reitz, G
    Enge, W
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 573 - 578