Using plastic track detectors to solve radiation safety problems at nuclear reactor facilities

被引:2
|
作者
Diakov, AA [1 ]
Rostovtsev, VY
Perekhojeva, TN
Zlokazova, EI
Betenekov, ND
Ipatova, EG
Antropov, OV
Denisov, EI
机构
[1] Sverdlovsk Branch Res & Dev, Inst Power Engn, Zarechny 624051, Sverdlovsk, Russia
[2] Ural State Tech Univ, UGTU, UPI, Ekaterinburg, Russia
关键词
liquid radioactive waste; coolant; uranium and plutonium microconcentrations; plastic track detectors; thin-layer inorganic sorbents; radiochemical concentrating;
D O I
10.1016/S1350-4487(97)00100-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Three options of the method to determine microconcentrations of fissile materials in water solutions are developed. They utilize plastic track detectors to measure concentrations. The options are as follows a "wet" method, "thin-layer inorganic sorbents-plastic track detectors", and a method of selective extraction and coprecipitation. These methods are used to check up fuel cladding integrity at the research reactor IVV-2M and liquid radioactive waste contamination by uranium and plutonium at the Beloyarskaya Nuclear Power Plant (BNPP).
引用
下载
收藏
页码:357 / 361
页数:5
相关论文
共 50 条
  • [1] RADON DOSIMETRY USING PLASTIC NUCLEAR TRACK DETECTORS
    FRANK, AL
    BENTON, EV
    NUCLEAR TRACK DETECTION, 1977, 1 (3-4): : 149 - 179
  • [2] SEARCH FOR ANOMALONS USING PLASTIC NUCLEAR TRACK DETECTORS
    HEINRICH, W
    DRECHSEL, H
    BRECHTMANN, C
    DREUTE, J
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 327 - 330
  • [3] A SEARCH FOR ANOMALONS USING PLASTIC NUCLEAR TRACK DETECTORS
    DRECHSEL, H
    TRAKOWSKI, W
    DREUTE, J
    SONNTAG, S
    BRECHTMANN, C
    RUDAT, R
    BEER, J
    HEINRICH, W
    BENTON, EV
    CASSOU, RM
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 563 - 566
  • [4] INTRODUCTION TO PLASTIC NUCLEAR TRACK DETECTORS
    ENGE, W
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1980, 4 (04): : 283 - &
  • [5] SEARCH FOR ANOMALONS USING PLASTIC NUCLEAR TRACK DETECTORS.
    Drechsel, H.
    Trakowski, W.
    Dreute, J.
    Sonntag, S.
    Brechtmann, C.
    Rudat, R.
    Beer, J.
    Heinrich, W.
    Benton, E.V.
    Cassou, R.M.
    Nuclear tracks, 1983, 8 (1-4): : 563 - 566
  • [6] SEARCH FOR ANOMALONS USING PLASTIC NUCLEAR TRACK DETECTORS.
    Heinrich, W.
    Brechtmann, C.
    Dreute, J.
    Dreschel, H.
    1600, (12): : 1 - 6
  • [7] RECENT DEVELOPMENTS IN RADIATION MEASUREMENTS USING NUCLEAR TRACK DETECTORS
    HASSIB, GM
    RADIATION PHYSICS AND CHEMISTRY, 1994, 44 (1-2): : 53 - 55
  • [8] Alpha radiation dosimetry using Fluorescent Nuclear Track Detectors
    Kouwenberg, J. J. M.
    de Pooter, J. A.
    Wolterbeek, H. T.
    Denkova, A. G.
    Bos, A. J. J.
    RADIATION MEASUREMENTS, 2018, 113 : 25 - 32
  • [9] AN AUTOMATIC TRACK ANALYSIS FOR LARGE AREAS PLASTIC NUCLEAR TRACK DETECTORS
    SONNTAG, S
    TRAKOWSKI, W
    HEINRICH, W
    BEER, J
    TITTEL, HO
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 259 - 262
  • [10] THE DEVELOPMENT AND UPGRADING OF RADIATION SAFETY PROGRAMS AT NUCLEAR-POWER REACTOR FACILITIES
    VANWYCK, RW
    HEALTH PHYSICS, 1980, 39 (06): : 1024 - 1025