摘要
In this paper, the implicit method of characteristics (IMCC) is extended to simulate the transient flow caused by load variation of hydroelectric power plants. The IMOC was proposed recently by the authors to remove the limitations of the commonly used conventional method of characteristics (MOC) and subsequently used for the simulation of transient flow caused by valve closure and pump failure. In the IMOC, an element-wise definition is used for all devices that may be used in a pipeline system and the corresponding equations are then assembled to form a system of equations that is solved for the unknown nodal heads and flows at each time step. In this paper, the IMCC is extended for the simulation of transient flow in the pipeline system upstream of a hydroelectric power plant. For this, an element-wise definition of the hydroelectric power plants and simple surge tank is proposed and their governing equations are derived in a matrix form required by the IMCC. Then these equations are assembled along with those of other devices of the pipeline system to construct a system of equations that is solved for the unknown head and flow. To further improve the convergence characteristics of the method, an improved formulation of the turbine is also proposed. In the proposed formulation, one of the turbine characteristic parameters, namely turbine net head, is used in addition to turbine head and discharges, to formulate the behavior of the turbine element. The method is applied to a problem of transient flow caused by load rejection and acceptance and the results are presented and compared with those of the explicit MOC. The results show the ability of the proposed method to accurately predict the variations of head and flow in the cases considered. it is also shown that the improved formulation of the turbine is computationally more efficient than the original formulation while producing the same results. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:103 / 115
页数:13
相关论文
共 50 条
  • [41] Improved load flow method for ungrounded distribution power systems
    Kang, Jun
    Ma, Wei-Ming
    Fu, Li-Jun
    Ma, Fan
    Yang, Hua
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2009, 13 (01): : 88 - 92
  • [42] Load flow in systems occurring in overhead natural power lines
    Gomes, Flávio V.
    Vinagre, Márcio P.
    Pereira, José L.R.
    Garcia, Paulo N.
    [J]. Controle y Automacao, 2002, 13 (03): : 290 - 297
  • [43] Interval Load Flow for Uncertainty Consideration in Power Systems Analysis
    Nogueira, Wallisson C.
    Garces Negrete, Lina Paola
    Lopez-Lezama, Jesus M.
    [J]. ENERGIES, 2021, 14 (03)
  • [44] A Combined Load Flow Method for Large Shipboard Power Systems
    Huang Jing
    Zhang XiaoFeng
    Ye ZhiHao
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1787 - 1792
  • [45] Soccer league optimization for load flow analysis of power systems
    Srilakshmi, Koganti
    Babu, P. Ravi
    Venkatesan, Yogambari
    Palanivelu, Aravindhababu
    [J]. INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2022, 35 (02)
  • [46] Development of unbalanced load flow program for large power systems
    [J]. Suzuki, Mamoru, 1600, Scripta Technica Inc, New York (114):
  • [47] An efficient power flow algorithm for distribution systems with polynomial load
    Liu, Jianwei
    Salama, M. M. A.
    Mansour, R. R.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2002, 39 (04) : 371 - 386
  • [48] Development of unbalanced load flow program for large power systems
    [J]. Suzuki, Mamoru, 1600, Scripta Technica Inc, New York, NY, United States (114):
  • [49] Transient behavior of two-stage load rejection for multiple units system in pumped storage plants
    Chen, Sheng
    Wang, Jing
    Zhang, Jian
    Yu, Xiaodong
    He, Wei
    [J]. RENEWABLE ENERGY, 2020, 160 : 1012 - 1022
  • [50] A simulation of the Static Condenser for the prevention of transient voltage instability due to induction motor load
    Yu, DC
    Liu, HJ
    [J]. PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59, I AND II, 1997, 59 : 1076 - 1081