Determination of interfacial tension of insulating oils by using image analysis and multi-way calibration

被引:24
|
作者
Godinho, Mariana S. [1 ]
Oliveira, Anselmo E. [2 ]
Sena, Marcelo M. [1 ]
机构
[1] Univ Estadual Goias, Unidade Univ Ciencias Exatas & Tecnol, BR-75000000 Anapolis, Go, Brazil
[2] Univ Fed Goias, Inst Quim, Goiania, Go, Brazil
关键词
Power transformers; Insulating oil; N-PLS; Three-way data; Chemometrics; N-way image analysis; MULTIVARIATE IMAGE; TRANSFORMERS INSULATION; CELLULOSIC INSULATION; POWER TRANSFORMERS; MOLECULAR-WEIGHT; DEGRADATION; PAPER; CHROMATOGRAPHY; WATER;
D O I
10.1016/j.microc.2010.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Power transformers are of great importance in the distribution of electrical energy. One of their most important parts is the insulating system, consisting of Kraft paper immersed in insulating oil. One of the most important parameters used for evaluating the degradation of this system is the oil interfacial tension. The aim of this study was to determine the interfacial tension in samples of insulating oils by using image analysis combined with a multi-way calibration method, N-PLS (multilinear PLS). Forty eight oil samples were obtained, whose values of interfacial tension were determined by a tensiometer, and divided into calibration (38) and validation (10) sets. Scanner images were obtained, converted to grey-scale, domain transformed and stacked in a three-way data array, before modelling. The best N-PLS model was obtained with mean centering and three latent variables and provided a RMSEP of 3 dyn cm(-1). This model provided individual prevision errors between-14 and 16%, which were acceptable for electric energy companies. The proposed method was rapid and non-destructive, showing great advantages over the traditional ones, which are slow and produce chemical waste. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 45
页数:4
相关论文
共 50 条
  • [11] Square wave voltammetric pKa determination of aspirin using multi-way data analysis models
    Yazan, Zehra
    Eskikoy Bayraktepe, Dilek
    Dinc, Erdal
    CHEMICAL PAPERS, 2022, 76 (09) : 5389 - 5397
  • [12] Multi-way analysis of outer product arrays using PARAFAC
    Rutledge, Douglas N.
    Bouveresse, Delphine Jouan-Rimbaud
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 85 (02) : 170 - 178
  • [13] ANALYSIS OF MULTI-WAY (MULTI-MODE) DATA
    GELADI, P
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1989, 7 (1-2) : 11 - 30
  • [14] APPLICATION OF MULTI-WAY PARTIAL LEAST SQUARES CALIBRATION FOR SIMULTANEOUS DETERMINATION OF RADIOISOTOPES BY LIQUID SCINTILLATION TECHNIQUE
    Mahani, Mohamad
    Ghomi, Homa Sheikh
    Mazloomifar, Ali
    Salimi, Bahram
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (02): : 125 - 130
  • [15] Testing effects of experimental design factors using multi-way analysis
    Liland, Kristian Hovde
    Faergestad, Ellen Mosleth
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2009, 96 (02) : 172 - 181
  • [16] Multi-way Functional Principal Components Analysis
    Allen, Genevera I.
    2013 IEEE 5TH INTERNATIONAL WORKSHOP ON COMPUTATIONAL ADVANCES IN MULTI-SENSOR ADAPTIVE PROCESSING (CAMSAP 2013), 2013, : 220 - 223
  • [17] A multi-way analysis of international bilateral claims
    Pecora, Nicola
    Spelta, Alessandro
    SOCIAL NETWORKS, 2017, 49 : 81 - 92
  • [18] ANALYSIS OF INCOMPLETE MULTI-WAY CONTINGENCY TABLES
    FIENBERG, SE
    BIOMETRICS, 1972, 28 (01) : 177 - &
  • [19] A multi-way analysis of starch cassava properties
    Reis, MM
    Ferreira, MMC
    Sarmento, SBS
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2002, 64 (02) : 123 - 135
  • [20] Multi-way based calibration transfer between two Raman spectrometers
    Kompany-Zareh, Mohsen
    van den Berg, Frans
    ANALYST, 2010, 135 (06) : 1382 - 1388