Performance evaluation of boron removal from wastewater containing high boron content according to operating parameters by air gap membrane distillation

被引:18
|
作者
Eryildiz, Bahriye [1 ,2 ]
Yuksekdag, Ayse [1 ,2 ]
Korkut, Sevde [1 ,2 ]
Koyuncu, Ismail [1 ,2 ]
机构
[1] Istanbul Tech Univ, Natl Res Ctr Membrane Technol, TR-34469 Istanbul, Turkey
[2] Istanbul Tech Univ, Environm Engn Dept, TR-34469 Istanbul, Turkey
关键词
Membrane distillation; High boron content; Air gap membrane distillation; Boron removal; Operating parameters; AQUEOUS-SOLUTIONS; DESALINATION; SEAWATER; ELECTROCOAGULATION;
D O I
10.1016/j.eti.2021.101493
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The removal performance of boron from real wastewater was conducted to determine the effect of different parameters on permeate water flux and boron removal efficiency by air gap membrane distillation (AGMD) system in this study. These parameters include boron concentration, membrane pore size, and membrane material. Before real wastewater tests, the experiments were conducted with saline water (%1 (w/v) NaCl) to stabilize the air gap membrane distillation system. Then, experiments were carried out in an air gap membrane distillation system using real wastewater. In the experiments, two different membrane materials (polytetrafluoroethylene (PTFE) and polypropylene (PP)) were used to examine the effect of membrane material. Also, experiments were conducted with membranes that have mean pore size of 0.20 and 0.45 mu m to examine the effect of membrane pore size on the permeate flux. To evaluate the effect of boron concentration, wastewaters at three different boron concentrations (2598, 2795 and 6242 mg/L B) were treated in the AGMD system. The results illustrate that removal of boron in all conditions was obtained above 99%. In conclusion, increasing boron concentration at feed wastewater, permeate water flux was decreased. When the mean pore size was increased from 0.20 to 0.45 mu m, permeate flux was enhanced. Furthermore, PP membranes had the maximum permeate flux in AGMD tests. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Performance evaluation of hollow fiber air gap membrane distillation module with multiple cooling channels
    Aryapratama, Rio
    Koo, Heoncheol
    Jeong, Seongpil
    Lee, Seockheon
    [J]. DESALINATION, 2016, 385 : 58 - 68
  • [32] Effects of process conditions on simultaneous removal and recovery of boron from boron-laden wastewater using improved bipolar membrane electrodialysis (BMED)
    Hung, Wei-Cheng
    Horng, Richard S.
    Tsai, Chia-Hsun
    [J]. JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [33] Synthesis of borosilicalite-1 with high boron content from fluoride containing media
    Testa, F
    Chiappetta, R
    Crea, F
    Aiello, R
    Fonesca, A
    Nagy, JB
    [J]. CATALYSIS BY MICROPOROUS MATERIALS, 1995, 94 : 349 - 356
  • [34] Effects of pH on boron accumulation in cattail (Typha latifolia) shoots, and evaluation of floating islands and upward flow mesocosms for the removal of boron from wastewater
    Junliang Xin
    Baifei Huang
    [J]. Plant and Soil, 2017, 412 : 163 - 176
  • [35] Effects of pH on boron accumulation in cattail (Typha latifolia) shoots, and evaluation of floating islands and upward flow mesocosms for the removal of boron from wastewater
    Xin, Junliang
    Huang, Baifei
    [J]. PLANT AND SOIL, 2017, 412 (1-2) : 163 - 176
  • [36] Performance increase of membrane distillation pilot scale modules operating in vacuum-enhanced air-gap configuration
    Andres-Manas, J. A.
    Ruiz-Aguirre, A.
    Acien, F. G.
    Zaragoza, G.
    [J]. DESALINATION, 2020, 475
  • [37] Selective removal of boron from industrial wastewater containing high concentration of ammonia by radiation grafted fibrous adsorbent in fixed bed column
    Ting, Teo Ming
    Nasef, Mohamed Mahmoud
    Aravindan, Deepalakshmi
    Rosslan, Izzatul Farah Nadiah
    Ruslan, Nurfazira
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (01):
  • [38] Removal of boron from industrial wastewater using PVP/PVDF blend membrane and GO/PVP/PVDF hybrid membrane by pervaporation
    Mehtap Ozekmekci
    Derya Unlu
    Mehmet Copur
    [J]. Korean Journal of Chemical Engineering, 2021, 38 : 1859 - 1869
  • [39] Removal of boron from industrial wastewater using PVP/PVDF blend membrane and GO/PVP/PVDF hybrid membrane by pervaporation
    Ozekmekci, Mehtap
    Unlu, Derya
    Copur, Mehmet
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2021, 38 (09) : 1859 - 1869
  • [40] Boron removal from geothermal water by nanofiber-based membrane distillation membranes with significantly improved surface hydrophobicity
    Ozbey-Unal, Bahar
    Gezmis-Yavuz, Elifnur
    Eryildiz, Bahriye
    Koseoglu-Imer, Derya Y.
    Keskinler, Bulent
    Koyuncu, Ismail
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (05):