Scleral Fixation of Intraocular Lenses with Gore-Tex Suture Refractive Outcomes and Comparison of Lens Power Formulas

被引:28
|
作者
Botsford, Benjamin W. [1 ]
Williams, Andrew M. [1 ]
Conner, Ian P. [1 ]
Martel, Joseph N. [1 ]
Eller, Andrew W. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Ophthalmol, Eye & Ear Inst, Pittsburgh, PA USA
来源
OPHTHALMOLOGY RETINA | 2019年 / 3卷 / 06期
关键词
D O I
10.1016/j.oret.2019.02.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report refractive outcomes of scleral-fixated intraocular lens (IOL) implantation with Gore-Tex (W.L. Gore & Associates, Newark, DE) suture and combined pars plana vitrectomy and compare predicted refractive outcomes among 5 IOL power calculation formulas. Design: Retrospective case series. Participants: Patients undergoing scleral-fixated IOL implantation with Gore-Tex suture at our institution between January 2015 and June 2018. Methods: Comparison of preoperative biometrics with postoperative refraction and calculation of predicted refractive outcome with 5 different IOL formulas. Main outcome measures: Prediction error and absolute error to compare postoperative refraction with refraction predicted by lens power calculation formulas. Results: Thirty-one eyes of 31 patients were included. All power calculations assumed in-the-bag position of the IOL. The Akreos A060 (Bausch & Lomb, Rochester, NY) was implanted in 23 eyes and the CZ70BD (Alcon, Fort Worth, TX) in 8 eyes, and all lenses were sutured 3 mm behind the limbus. Average postoperative spherical equivalent (SE) was -0.79 +/- 0.95 diopters (D). Average prediction error (postoperative SE refraction minus target refraction) was -0.19 +/- 0.72 D. Postoperative SE was within 1.0 D of target in 25 of 31 patients (81%) and 2.0 D of target in 31 of 31 patients (100%). The repeated-measures analysis of variance of absolute error by lens power formula was significant (P = 0.012), with Haigis demonstrating greater error. There was no significant difference among Barrett II, Sanders-Retzlaff-Kraff theoretical (SRK/T), Holladay 2, or Hoffer Q. Conclusions: For eyes undergoing pars plana vitrectomy with scleral-sutured IOL implantation, assumption of in-the-bag IOL position when calculating lens power leads to acceptable refractive outcomes. Barrett II, SRK/T, Holladay 2, and Hoffer Q formulas were noninferior to each other. (C)2019 by the American Academy of Ophthalmology
引用
收藏
页码:468 / 472
页数:5
相关论文
共 50 条
  • [21] ONE-YEAR OUTCOMES OF A NOVEL SURGICAL APPROACH FOR FIXATION OF A POSTERIOR CHAMBER INTRAOCULAR LENS USING GORE-TEX SUTURE
    Bonnell, Alyssa C.
    Mantopoulos, Dimosthenis
    Fine, Howard F.
    Shah, Sumit P.
    Wheatley, H. Matthew
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (05): : 833 - 837
  • [22] Four-point subconjunctival scleral fixation technique using Gore-Tex suture
    Lee, Kenneth R. C. K.
    Fung, Adrian T.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (04): : 397 - 399
  • [23] A novel surgical approach for fixation of a posterior chamber intraocular lens of Rayner 620 H with Gore-Tex suture
    Wang, Tan
    Chen, Youxin
    Lu, Jun
    Li, Ningning
    Min, Hanyi
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [24] A novel surgical approach for fixation of a posterior chamber intraocular lens of Rayner 620 H with Gore-Tex suture
    Tan Wang
    Youxin Chen
    Jun Lu
    Ningning Li
    Hanyi Min
    BMC Ophthalmology, 23
  • [25] Combined 27-Gauge Pars Plana Vitrectomy and Scleral Fixation of an Akreos AO60 Intraocular Lens Using Gore-Tex Suture
    Khan, Mohammed Ali
    Rahimy, Ehsan
    Gupta, Omesh P.
    Hsu, Jason
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (08): : 1602 - 1604
  • [26] Four-point subconjunctival scleral fixation technique using Gore-Tex suture: Response
    Shah, Yachana
    Shah, Vaibhav
    Raja, Vignesh
    Barrett, Graham D.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (04): : 399 - 400
  • [27] Clinical Outcomes of Pars Plana Vitrectomy and Polytetrafluoroethylene (Gore-Tex) Scleral Fixation of a Monofocal Aspheric Intraocular Lens (Akreos AO60)
    Mishra, Amit V.
    Martens, Rosanna
    Loh, Graeme K.
    Somani, Rizwan
    Greve, Mark D. J.
    Seamone, Mark E.
    JOURNAL OF VITREORETINAL DISEASES, 2024, 8 (05) : 540 - 545
  • [28] Estimation of structural integrity of Rayner RA0600C intraocular lens in a model of transscleral fixation with the Gore-Tex suture
    Bhatia, Niharika
    Gorrai, Ananya
    Astafurov, Konstantin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [29] Z-suture scleral fixation intraocular lenses: A refractive and safety report
    Barbosa, Renato Correia
    Carvalho, Rui
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024,
  • [30] Retropupillary iris claw lens versus Gore-Tex assisted scleral fixated intraocular lens in children with large lens subluxations
    Rastogi, Anju
    Gaonker, Tanvi
    Dhiman, Shweta
    Singh, Kirti
    Anand, Kamlesh
    Suresh, Priyadarshini
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (06) : 2002 - 2009