Effect of round curvature of anterior implant-supported zirconia frameworks: finite element analysis and in vitro study using digital image correlation

被引:4
|
作者
Messias, Ana [1 ,2 ]
Augusta Neto, Maria [2 ]
Amaro, Ana Martins [2 ]
Nicolau, Pedro [1 ,2 ]
Roseiro, Luis Manuel [3 ]
机构
[1] Univ Coimbra, Dept Dent, Fac Med, Coimbra, Portugal
[2] Univ Coimbra, Fac Sci & Technol, Ctr Mech Engn Mat & Proc, CEMMPRE, Coimbra, Portugal
[3] Polytech Inst Coimbra, ISEC DEM, Coimbra, Portugal
关键词
Zirconia framework; anterior restorations; round curvature of FPDs; digital image correlation; finite element analysis; FIXED DENTAL PROSTHESES; FRACTURE-RESISTANCE; CLINICAL-EVALUATION; STRESS-DISTRIBUTION; CONNECTOR DESIGNS; PARTIAL DENTURES; STRENGTH; SURVIVAL;
D O I
10.1080/10255842.2017.1348501
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Two groups of 4-unit zirconia frameworks were produced by CAD/CAM to simulate the restoration of an anterior edentulous gap supported by 2 implant-abutment assemblies. Group 1 comprised straight configuration frameworks and group 2 consisted of arched frameworks. Specimens were made with the same connector cross-section area and were cemented and submitted to static loads. Displacements were captured with two high-speed photographic cameras and analysed with video correlation system. Frameworks and the implant-abutment assembly were scanned and converted to 3DCAD objects by reverse engineering process. A specimen of each group was veneered and the corresponding 3D geometry was similarly obtained after scanning. Numerical models were created from the CAD objects and the FE analysis was performed on the zirconia frameworks and on the FPDs bi-layered with porcelain (veneered frameworks). Displacements were higher for the curved frameworks group, under any load. The predicted displacements correlated well with the experimental values of the two framework groups, but on the straight framework the experimental vertical displacements were superior to those predicted by the FEA. The results showed that the round curvature of zirconia anterior implant-supported FPDs plays a significant role on the deformation/stress of FPDs that cannot be neglected neither in testing nor in simulation and should be considered in the clinical setting.
引用
收藏
页码:1236 / 1248
页数:13
相关论文
共 50 条
  • [41] In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns
    Aristeidis A. Villias
    Stefanos G. Kourtis
    Hercules C. Karkazis
    Gregory L. Polyzois
    International Journal of Implant Dentistry, 7
  • [42] Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study
    Lee, Jae-In
    Lee, Yoon
    Kim, Yu-Lee
    Cho, Hye-Won
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (02): : 161 - 169
  • [43] Comparison of three implant systems under preload loss: A finite element analysis validated by digital image correlation methods
    Anniwaer, Annikaer
    Yin, Zhengrong
    Zhu, Jiakang
    Jin, Chunxiao
    Muhetaer, Aihemaiti
    Huang, Cui
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024,
  • [44] Digital Image Correlation and Finite Element Analysis of Bone Strain Generated by Implant-Retained Cantilever Fixed Prosthesis
    Tribst, Joao Paulo M.
    Dal Piva, Amanda M. O.
    Bottino, Marco Antonio
    Nishioka, Renato S.
    Borges, Alexandre L. S.
    Ozcan, Mutlu
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (01): : 10 - 17
  • [45] Accuracy of digital impressions for implant-supported complete-arch prosthesis, using an auxiliary geometry part-An in vitro study
    Iturrate, Mikel
    Eguiraun, Harkaitz
    Solaberrieta, Eneko
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (12) : 1250 - 1258
  • [46] Effect of Different Customized Abutment Types on Stress Distribution in Implant-Supported Single Crown: A 3D Finite Element Analysis
    Pumnil, Suphakrit
    Rungsiyakull, Pimduen
    Rungsiyakull, Chaiy
    Elsaka, Shaymaa
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : E2 - E11
  • [47] Effect of crown stiffness and prosthetic screw absence on the stress distribution in implant-supported restoration: A 3D finite element analysis
    Epifania, Ettore
    di Lauro, Alessandro
    Ausiello, Pietro
    Mancone, Alessia
    Garcia-Godoy, Franklin
    Tribst, Joao Paulo Mendes
    PLOS ONE, 2023, 18 (05):
  • [48] A study of the thermal buckling behavior of a circular aluminum plate using the digital image correlation technique and finite element analysis
    Jin, T. L.
    Ha, N. S.
    Goo, N. S.
    THIN-WALLED STRUCTURES, 2014, 77 : 187 - 197
  • [49] A 3D Finite Element Analysis of Bone Tissue in 3-Unit Implant-Supported Prostheses: Effect of Splinting Factor and Implant Length and Diameter
    de Souza Batista, Victor E.
    Verri, Fellippo R.
    Lemos, Cleidiel A.
    Cruz, Ronaldo S.
    Noritomi, Pedro Y.
    Pellizzer, Eduardo P.
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (02): : 76 - 83
  • [50] The Effect of Implantoplasty on Fracture Resistance and Implant Surface Changes: An In Vitro and Finite Element Analysis Study
    Goh, Rayner
    Li, Kai Chun
    Atieh, Momen A.
    Ma, Sunyoung
    Oliver, Abigail
    Giraldo, Diana
    Tawse-Smith, Andrew
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (01)