Effect on Radiant Heat Transfer at the Surface of a Pool Fire Interacting With a Water Mist

被引:3
|
作者
Garo, J. P. [1 ]
Vantelon, J. P. [1 ]
Lemonnier, D. [2 ]
机构
[1] Univ Poitiers, Lab Combust & Deton, ENSMA, F-86961 Futuroscope, France
[2] Univ Poitiers, Lab Etud Therm, ENSMA, F-86961 Futuroscope, France
来源
关键词
flames; heat transfer; water; THERMAL-RADIATION; ATTENUATION; PROTECTION; SPRAYS; MODEL;
D O I
10.1115/1.4000185
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is well established that the use of water mist can be an attractive alternative to gaseous suppression agents to extinguish fires for specific scenarios. Among the main mechanisms, which act together to extinguish fires when using a water mist: heat extraction, oxygen displacement, and radiant heat attenuation, the last one has received the less attention, especially regarding the energy balance at the fuel surface and, therefore, the rate of generation of flammable vapors. The objective of this work is to analyze, on the one hand, the perturbing influence of a mist addition as an opposed flow to a small-scale liquid (heptane) pool fire structure, especially at its base, the more interesting zone regarding the mechanisms of flame stabilization and extinction and, on the other hand, the effect on the surface radiant heat feedback. Experiments conducted give an order of magnitude estimate in essential agreement with a radiation computation, based on the mappings, previously obtained, of the two major parameters: temperature and extinction coefficient, that determine the thermal radiation of the flame. The important information is the confirmation that radiation attenuation cannot be identified as a predominant mechanism of extinguishment.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Experimental study of pool fire suppression by water mist in enclosure
    State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou 310027, China
    不详
    [J]. Zhejiang Daxue Xuebao (Gongxue Ban), 2007, 6 (1029-1035):
  • [22] Spray characteristics determination of water mist for suppressing pool fire
    Zheng, Li G.
    Yu, Ming G.
    Yu, Shui J.
    Liu, Zhi C.
    [J]. MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 530 - +
  • [23] Experimental study on the effectiveness of the extinction of a pool fire with water mist
    Wang, XS
    Liao, GX
    Qin, J
    Fan, WC
    [J]. JOURNAL OF FIRE SCIENCES, 2002, 20 (04) : 279 - 295
  • [24] Experimental Study on Radiant Heat of Market Shelf Fire Decayed By High-pressure Water Mist System
    Wang, Jianying
    Dong, Xilin
    [J]. ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 3699 - 3702
  • [25] Effect of surface roughness on pool boiling heat transfer
    Kang, MG
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (22) : 4073 - 4085
  • [26] Effect of composite coatings on surface characteristics and boiling heat transfer performance in a pool of water
    Kumar, Nitish
    Ghosh, Pradyumna
    Shukla, P.
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (02) : 671 - 685
  • [27] Effect of composite coatings on surface characteristics and boiling heat transfer performance in a pool of water
    Nitish Kumar
    Pradyumna Ghosh
    P. Shukla
    [J]. Journal of Thermal Analysis and Calorimetry, 2024, 149 (2) : 671 - 685
  • [28] Control effect on diesel pool fire by longitudinal smoke discharge and high pressure water mist
    Zhang, Peihong
    Feng, Rui
    Xu, Wenbin
    Tian, XiangLiang
    Shang, Rongxue
    [J]. ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 2798 - +
  • [29] Study on the effect of mist flux on water mist fire extinguishing
    Liu, Yang
    Fu, Zhixi
    Zheng, Guanghui
    Chen, Peng
    [J]. FIRE SAFETY JOURNAL, 2022, 130
  • [30] Thermal Environments Induced by a Pool Fire with and without Discharging Water Mist
    Gao, Y.
    Liu, P.
    Li, S. S.
    Chow, W. K.
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2009, 52 (03) : 176 - 182