Use of sensorineural tests in a large volume of medico-legal compensation claims for HAVS

被引:9
|
作者
McGeoch, KL
Lawson, IJ
Burke, F
Proud, G
Miles, J
机构
[1] Rolls Royce PLC, Derby DE24 8BJ, England
[2] Derby Royal Infirm, Derby DE1 2RR, England
[3] Royal Victoria Infirm, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
[4] Univ York, Dept Hlth Sci, York YO10 5DD, N Yorkshire, England
来源
OCCUPATIONAL MEDICINE-OXFORD | 2004年 / 54卷 / 08期
关键词
hand-arm vibration syndrome; HAVS; neurological component; sensorineural tests; staging;
D O I
10.1093/occmed/kqh112
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background The Department of Trade and Industry set up a contract to examine miners and ex-miners claiming compensation for hand-arm vibration syndrome (HAVS). They had been exposed to hand-transmitted vibration. Over 100 000 have now been examined using sensorineural tests as part of that process. Aims The purpose of this paper was to examine the internal consistency of the vibrotactile threshold test (VTT) and the thermal aesthesiometry test (TA). Methods In 18 centres across the UK, nurses were trained to perform the measurement of VTT and TA in a controlled standardized manner. These tests were to aid the staging of the neurological component of the Stockholm Workshop Scales. The staging of this component was modified by dividing stage 2SN into 2SN (early) and 2SN (late). The test results and an automatic neurological staging were presented to the examining doctor following the clinical examination. The results of these sensorineural tests were held on a central database. The results and analysis of the first 57 000 tests are reported. Results The correlations within the VTT and TA scores were consistent with reliable measures. However, these correlations were not of such strength as to allow reliance on the results of a single test when making an assessment of the severity of neurological damage. Conclusions Different end organs and nerve fibres should be tested when making an assessment of damage in the sensorineural component of HAVS. The correlations demonstrated for the VTT and TA suggest that they are of value in assessing these claimants and would be for other vibration exposed workers.
引用
收藏
页码:528 / 534
页数:7
相关论文
共 50 条
  • [31] MEDICO-LEGAL USE OF THE ASSAY OF LDH ISOENZYMES IN CSF
    CHAUMONT, AJ
    MANGIN, P
    LUGNIER, AAJ
    MILLET, A
    OFFNER, M
    GRUCKER, M
    JOURNAL DE MEDECINE LEGALE DROIT MEDICAL, 1983, 26 (02): : 143 - 153
  • [32] PATERNITY BLOOD GROUP TESTS MADE IN MEDICO-LEGAL INSTITUTE OF KRAKOW
    KOBIELA, J
    SOCHA, W
    ACTA MORPHOLOGICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1962, : 100 - +
  • [33] MEDICO-LEGAL USE OF PLACENTAL ALKALINE-PHOSPHATASE IN INFANTICIDE
    OYA, M
    ZEITSCHRIFT FUR RECHTSMEDIZIN-JOURNAL OF LEGAL MEDICINE, 1985, 94 (04): : 251 - 256
  • [34] Medico-legal risk and use of medical directives in the emergency department
    Cortel-LeBlanc, Miguel A.
    Lemay, Karen
    Woods, Sue
    Bakewell, Francis
    Liu, Richard
    Garber, Gary
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2023, 25 (07) : 589 - 597
  • [35] Medico-legal risk and use of medical directives in the emergency department
    Miguel A. Cortel-LeBlanc
    Karen Lemay
    Sue Woods
    Francis Bakewell
    Richard Liu
    Gary Garber
    Canadian Journal of Emergency Medicine, 2023, 25 : 589 - 597
  • [36] Use of contrast media in diagnostic imaging: medico-legal considerations
    Pomara, C.
    Pascale, N.
    Maglietta, F.
    Neri, M.
    Riezzo, I.
    Turillazzi, E.
    RADIOLOGIA MEDICA, 2015, 120 (09): : 802 - 809
  • [37] Use of contrast media in diagnostic imaging: medico-legal considerations
    C. Pomara
    N. Pascale
    F. Maglietta
    M. Neri
    I. Riezzo
    E. Turillazzi
    La radiologia medica, 2015, 120 : 802 - 809
  • [38] A RETROSPECTIVE LOOK AT 22 MEDICO-LEGAL CLAIMS - HOW THEY MIGHT HAVE BEEN AVOIDED
    BETTMAN, JW
    SURVEY OF OPHTHALMOLOGY, 1983, 28 (01) : 55 - 60
  • [39] Safety and medico-legal implications of intra-articular gadolinium use
    Balkissoon, ARA
    SEMINARS IN ULTRASOUND CT AND MRI, 1997, 18 (04) : 276 - 277