MEMS displacement generator for atomic force microscopy metrology

被引:3
|
作者
Babij, M. [1 ]
Majstrzyk, W. [1 ]
Sierakowski, A. [2 ]
Janus, P. [2 ]
Grabiec, P. [2 ]
Ramotowski, Z. [3 ]
Yacoot, A. [4 ]
Gotszalk, T. [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Ul Z Janiszewskiego 11-17, PL-50372 Wroclaw, Poland
[2] Lukasiewicz Res Network, Inst Electron Technol, Al Lotnikow 32-46, PL-02668 Warsaw, Poland
[3] Cent Off Measure, Ul Elektoralna 2, PL-00139 Warsaw, Poland
[4] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
关键词
nanometrology; scanning probe microscopy; MEMS;
D O I
10.1088/1361-6501/abc28a
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Atomic force microscopy enables three-dimensional high-resolution imaging of surfaces with nanoscale features. In order to obtain the quantitative information about surface geometry, the atomic force microscope's scanning system must be calibrated. This is usually done by using calibration samples of known and/or defined shape based on either lithographic or crystal structures. In this work we report on a microelectromechanical device, referred to as a displacement generator, whose vertical deflection is controlled electronically. The designed, fabricated and applied device is formed out of a silicon nitride doubly clamped lever, referred to as a microbridge, with a deposited pair of platinum strips. When the MEMS displacement generator is immersed in a magnetic field and when it is electrically biased, the associated Lorentz force induces a structural displacement. In the presented design, the silicon nitride microbridges were fabricated on a (110) silicon wafer in a Wheatstone bridge configuration. A second reference cantilever was mechanically supported by the silicon substrate. In this way, a highly symmetrical structure was fabricated, making it possible to control precisely deflection in Z direction with sub-nanometre precision. The cantilever's high resonance frequency, of ca. 500 kHz, makes the constructed device insensitive to external vibration sources which are typically at much lower frequencies. As the stage function can be described using the simple harmonic oscillator model, it is clear that the system can operate with sub-nanometre resolution, which, for the purpose of microscope calibration, is extremely beneficial. By placing of the atomic force microscope tip on the actuated reference device it is possible to determine the response of the system over a wide frequency bandwidth. In this work we will describe the fabrication process of the MEMS displacement generator, interferometric and traceable investigations of thermomechanical and electromagnetic actuation schemes. Moreover, we will present the results of the calibration of an atomic force microscope operating in contact and intermittent contact modes.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Metrology of electromagnetic static actuation of MEMS microbridge using atomic force microscopy
    Moczala, M.
    Majstrzyk, W.
    Sierakowski, A.
    Dobrowolski, R.
    Grabiec, P.
    Gotszalk, T.
    [J]. MICRON, 2016, 84 : 1 - 6
  • [2] Dimensional Metrology with Atomic Force Microscopy
    Dixson, Ronald
    Orji, Ndubuisi G.
    [J]. JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2012, 11 (01):
  • [3] Atomic force microscopy metrology of catalytic nanoparticles
    Bukharaev A.A.
    Ziganshina S.A.
    Chuklanov A.P.
    [J]. Nanotechnologies in Russia, 2010, 5 (5-6): : 364 - 376
  • [4] Accurate dimensional metrology with atomic force microscopy
    Dixson, R
    Köning, R
    Fu, J
    Vorburger, T
    Renegar, B
    [J]. METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XIV, 2000, 3998 : 362 - 368
  • [5] Advances in the atomic force microscopy for critical dimension metrology
    Hussain, Danish
    Ahmad, Khurshid
    Song, Jianmin
    Xie, Hui
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (01)
  • [6] METROLOGY OF ATOMIC-FORCE MICROSCOPY FOR SI NANOSTRUCTURES
    NAGASE, M
    NAMATSU, H
    KURIHARA, K
    IWADATE, K
    MURASE, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1995, 34 (6B): : 3382 - 3387
  • [7] Atomic force microscopy for cross section inspection and metrology
    Wilder, K
    Quate, CF
    Singh, B
    Alvis, R
    Arnold, WH
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (06): : 4004 - 4008
  • [8] Mems sensor for in situ TEM Atomic Force Microscopy
    Nafari, A.
    Karlen, D.
    Rusu, C.
    Svensson, K.
    Olin, H.
    Enoksson, P.
    [J]. PROCEEDINGS OF THE IEEE TWENTIETH ANNUAL INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, VOLS 1 AND 2, 2007, : 294 - +
  • [9] MEMS sensor for in situ TEM atomic force microscopy
    Nafari, Alexandra
    Karlen, David
    Rusu, Cristina
    Svensson, Krister
    Olin, Hakan
    Enoksson, Peter
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2008, 17 (02) : 328 - 333
  • [10] Towards nanoscale metrology for biomolecular imaging by atomic force microscopy
    Abdelhady, HG
    Allen, S
    Ebbens, SJ
    Madden, C
    Patel, N
    Roberts, CJ
    Zhang, JX
    [J]. NANOTECHNOLOGY, 2005, 16 (06) : 966 - 973