Performance of a new single-use bronchoscope versus a marketed single-use comparator: a bench study

被引:8
|
作者
Lamb, Carla R. [1 ,4 ]
Yavarovich, Ekaterina [1 ]
Kang, Vincent [1 ]
Servais, Elliot L. [2 ]
Sheehan, Lori B. [3 ,4 ]
Shadchehr, Sara [1 ,4 ]
Weldon, James [5 ]
Rousseau, Matthew J. [5 ]
Tirrell, Gregory P. [5 ]
机构
[1] Lahey Hosp & Med Ctr, Div Pulm & Crit Care, 41 Burlington Mall Rd, Burlington, MA 01805 USA
[2] Lahey Hosp & Med Ctr, Div Thorac Surg, Burlington, MA USA
[3] Lahey Hosp & Med Ctr, Div Anesthesiol, Burlington, MA USA
[4] Tufts Med Ctr, Dept Med, Boston, MA 02111 USA
[5] Boston Sci Corp, Marlborough, MA USA
关键词
Bronchoscopy; Disposable equipment; Interventional pulmonology; Medical technology; BRONCHOALVEOLAR LAVAGE; MANAGEMENT; SUCTION; DIAGNOSIS;
D O I
10.1186/s12890-022-01982-4
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Single-use flexible bronchoscopes eliminate cross contamination from reusable bronchoscopes and are cost-effective in a number of clinical settings. The present bench study aimed to compare the performance of a new single-use bronchoscope (Boston Scientific EXALT Model B) to a marketed single-use comparator (Ambu aScope 4), each in slim, regular and large diameters. Methods Three bronchoscopy tasks were performed: water suction and visualization, "mucus" mass (synthetic mucoid mixture) suctioned in 30 s, and "mucus" plug (thicker mucoid mixture) suction. Suction ability, task completion times, and subjective ratings of visualization and overall performance on a scale of one to 10 (best) were compared. All bronchoscopy tasks were completed by 15 physicians representing diversity in specialization including pulmonary, interventional pulmonary, critical care, anesthesia, and thoracic surgery. Each physician utilized the six bronchoscope versions with block randomization by bronchoscope and task. Results Aspirated mean mass of "mucus" using EXALT Model B Regular was comparable to that for an aScope 4 Large (41.8 +/- 8.3 g vs. 41.5 +/- 5.7 g respectively, p = 0.914). In comparisons of scopes with the same outer diameter, the aspirated mean mass by weight of water and "mucus" was significantly greater for EXALT Model B than for aScope 4 (p < 0.001 for all three diameters). Mean ratings for visualization attributes were significantly better for EXALT Model B compared to aScope 4 (p-value range 0.001-0.029). Conclusion A new single-use bronchoscope provided strong suction capability and visualization compared to same-diameter marketed single-use comparators in a bench model simulation.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Avoiding a Lemon: Performance Consistency of Single-Use Ureteroscopes
    Winship, Brenton
    Wollin, Daniel
    Carlos, Evan
    Li, Jingqiu
    Preminger, Glenn M.
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2019, 33 (02) : 127 - 131
  • [42] Evaluation of the Suction Capabilities of Currently Available Single-use Flexible Bronchoscopes: A Bench Study
    Reddy, C.
    Heck, B.
    Iravani, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [43] AVOIDING A LEMON: PERFORMANCE CONSISTENCY OF SINGLE-USE URETEROSCOPES
    Winship, Brenton
    Wollin, Daniel
    Carlos, Evan
    Li, Jingqiu
    Terry, Russell
    Boydston, Kohldon
    Preminger, Glenn
    Lipkin, Michael
    JOURNAL OF UROLOGY, 2019, 201 (04): : E1160 - E1160
  • [44] Why not use single-use marker pens?
    Hocken, David B.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2008, 90 (06) : 530 - 530
  • [45] Performance Metrics of a Novel Single-Use Therapeutic Gastroscope
    Liu, Nanlong
    Marino, Daniel
    Cool, Christina
    Hoffman, David
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S659 - S659
  • [46] Performance of a single-use gastroscope for esophagogastroduodenoscopy: Prospective evaluation
    van der Ploeg, Koen
    de Jonge, Pieter J. F.
    Lammers, Wim J.
    Koch, Arjun Dave
    Vos, Margreet C.
    Paulsen, Vemund
    Aabakken, Lars
    Bruno, Marco
    ENDOSCOPY INTERNATIONAL OPEN, 2024, 12 (03) : E428 - E434
  • [47] Performance of single-use syringe versus multi-use MR contrast injectors: a prospective comparative study
    F. Struik
    J. J. Futterer
    W. M. Prokop
    Scientific Reports, 10
  • [48] Performance of single-use syringe versus multi-use MR contrast injectors: a prospective comparative study
    Struik, F.
    Futterer, J. J.
    Prokop, W. M.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [49] Environmental impact and life cycle financial cost of hybrid (reusable/single-use) instruments versus single-use equivalents in laparoscopic cholecystectomy
    Rizan, Chantelle
    Bhutta, Mahmood F.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (06): : 4067 - 4078
  • [50] Environmental impact and life cycle financial cost of hybrid (reusable/single-use) instruments versus single-use equivalents in laparoscopic cholecystectomy
    Chantelle Rizan
    Mahmood F. Bhutta
    Surgical Endoscopy, 2022, 36 : 4067 - 4078