Performance of a new single-use bronchoscope versus a marketed single-use comparator: a bench study

被引:8
|
作者
Lamb, Carla R. [1 ,4 ]
Yavarovich, Ekaterina [1 ]
Kang, Vincent [1 ]
Servais, Elliot L. [2 ]
Sheehan, Lori B. [3 ,4 ]
Shadchehr, Sara [1 ,4 ]
Weldon, James [5 ]
Rousseau, Matthew J. [5 ]
Tirrell, Gregory P. [5 ]
机构
[1] Lahey Hosp & Med Ctr, Div Pulm & Crit Care, 41 Burlington Mall Rd, Burlington, MA 01805 USA
[2] Lahey Hosp & Med Ctr, Div Thorac Surg, Burlington, MA USA
[3] Lahey Hosp & Med Ctr, Div Anesthesiol, Burlington, MA USA
[4] Tufts Med Ctr, Dept Med, Boston, MA 02111 USA
[5] Boston Sci Corp, Marlborough, MA USA
关键词
Bronchoscopy; Disposable equipment; Interventional pulmonology; Medical technology; BRONCHOALVEOLAR LAVAGE; MANAGEMENT; SUCTION; DIAGNOSIS;
D O I
10.1186/s12890-022-01982-4
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Single-use flexible bronchoscopes eliminate cross contamination from reusable bronchoscopes and are cost-effective in a number of clinical settings. The present bench study aimed to compare the performance of a new single-use bronchoscope (Boston Scientific EXALT Model B) to a marketed single-use comparator (Ambu aScope 4), each in slim, regular and large diameters. Methods Three bronchoscopy tasks were performed: water suction and visualization, "mucus" mass (synthetic mucoid mixture) suctioned in 30 s, and "mucus" plug (thicker mucoid mixture) suction. Suction ability, task completion times, and subjective ratings of visualization and overall performance on a scale of one to 10 (best) were compared. All bronchoscopy tasks were completed by 15 physicians representing diversity in specialization including pulmonary, interventional pulmonary, critical care, anesthesia, and thoracic surgery. Each physician utilized the six bronchoscope versions with block randomization by bronchoscope and task. Results Aspirated mean mass of "mucus" using EXALT Model B Regular was comparable to that for an aScope 4 Large (41.8 +/- 8.3 g vs. 41.5 +/- 5.7 g respectively, p = 0.914). In comparisons of scopes with the same outer diameter, the aspirated mean mass by weight of water and "mucus" was significantly greater for EXALT Model B than for aScope 4 (p < 0.001 for all three diameters). Mean ratings for visualization attributes were significantly better for EXALT Model B compared to aScope 4 (p-value range 0.001-0.029). Conclusion A new single-use bronchoscope provided strong suction capability and visualization compared to same-diameter marketed single-use comparators in a bench model simulation.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Performance of a new single-use bronchoscope versus a marketed single-use comparator: a bench study
    Carla R. Lamb
    Ekaterina Yavarovich
    Vincent Kang
    Elliot L. Servais
    Lori B. Sheehan
    Sara Shadchehr
    James Weldon
    Matthew J. Rousseau
    Gregory P. Tirrell
    BMC Pulmonary Medicine, 22
  • [2] Single-use Versus Multi-use Catheters: Pro Single-use Catheters
    Walter, Matthias
    Krassioukov, Andrei V.
    EUROPEAN UROLOGY FOCUS, 2020, 6 (05): : 807 - 808
  • [3] PERFORMANCE OF SINGLE-USE RESPIRATORS
    LOWRY, PL
    HESCH, PR
    REVOIR, WH
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (09): : 462 - 467
  • [4] ERCP in the era of single-use endcaps and single-use duodenoscopes
    Shor, Dana Ben-Ami
    GASTROINTESTINAL ENDOSCOPY, 2025, 101 (03) : 669 - 670
  • [5] Single-use versus reusable devices
    McCormick, RD
    BIOMEDICAL INSTRUMENTATION & TECHNOLOGY, 1996, 30 (05) : 407 - 410
  • [6] Reusable Versus Single-Use Endoscopes
    Fischer, Lindsay
    AORN JOURNAL, 2024, 120 (01) : P3 - P6
  • [7] Environmental impact of hybrid (reusable/single-use) ports versus single-use equivalents in robotic surgery
    Rizan, Chantelle
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [8] Single-Use Consumables
    Baddeley, Robin
    Aabakken, Lars
    Veitch, Andrew
    Hayee, Bu'hussain
    GASTROENTEROLOGY, 2022, 162 (06) : 1557 - 1558
  • [9] Single-use Duodenoscope
    Lanka, Chandana
    Bhenswala, Prashant
    Lakhana, Muhddesa
    Shah, Neal C.
    Srivastava, Pranay
    Andalib, Iman
    Gress, Frank
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2024, 58 (10) : 957 - 962
  • [10] Single-Use Technology
    Detroy, Andrea
    Matz, Christian
    Leykin, Mark
    Jenness, Ernest
    Acucena, Ross W.
    BIOPHARM INTERNATIONAL, 2014, 27 (03) : 48 - +