Cyclic olefin polymer membrane as an emerging material for CO2 capture in gas-liquid membrane contactor

被引:8
|
作者
Sabzekar, Malihe [1 ]
Chenar, Mahdi Pourafshari [1 ]
Khayet, Mohamed [2 ,3 ]
Garcia-Payo, Carmen [2 ]
Maghsoud, Zahra [1 ]
Pagliero, Marcello [4 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Engn, Dept Chem Engn, Mashhad, Iran
[2] Univ Complutense Madrid, Fac Phys, Dept Struct Matter Thermal Phys & Elect, Avda Complutense S-N, Madrid 28040, Spain
[3] IMDEA Water Inst, Avda Punto Com 2, Alcala De Henares 28805, Madrid, Spain
[4] Univ Genoa, Dept Chem & Ind Chem, Membrane & Membrane Res Grp, Via Dodecaneso 31, I-16146 Genoa, Italy
来源
关键词
Cyclic olefin polymer (COP); Membrane contactor; Porous flat-sheet membrane; Non-solvent induced phase separation; CO2; absorption; OF-THE-ART; PERFORMANCE; ABSORPTION;
D O I
10.1016/j.jece.2024.107669
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Porous flat sheet membranes were prepared with a commercial grade of cyclic olefin polymer (COP) for CO2 capture using membrane contactor (MC). The membranes were prepared via non-solvent induced phase separation technique using different types of additives, namely, polyvinylpyrrolidone (PVP), polyethylene glycol (PEG400) and sorbitan monooleate (Span 80), and coagulants (acetone and 70/30 wt% acetone/water mixture) were investigated. The prepared membranes were characterized in terms of the thickness (70-85 mu m), porosity (50-80%), mean pore size (158-265 nm), bubble pore size (similar to 0.6-12 mu m), liquid entry pressure (1.67-4.55 bar), water contact angle (similar to 94 degrees - 111 degrees), monoethanolamine (MEA) contact angle (similar to 67 degrees - 73 degrees) and mechanical properties (tensile strength: 4.53 - 5.15 MPa, elongation at break: 4 - 8% and Young's modulus: 190 - 232 MPa). The thermodynamic study of COP membranes proved that a fast phase inversion of the proposed system resulted in a more porous structure. The addition of PEG400 and Span 80 caused delayed demixing and influenced the morphological structure and MC performance. The structural and topographical characteristics of the membranes were also studied. The CO2 absorption test performed at 27 degrees C showed that the maximum CO2 absorption flux was around 16 x 10(-5) mol/m(2).s using 1 M MEA aqueous solution as absorbent with fixed liquid and gas flow rates at 150 L/h and 8.4 L/h, respectively. It was found that the considered additives enhanced the MC performance and affected the CO2 absorption flux.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Innovative Gas-Liquid Membrane Contactor Systems for Carbon Capture and Mineralization in Energy Intensive Industries
    Asimakopoulou, Akrivi
    Koutsonikolas, Dimitrios
    Kastrinaki, Georgia
    Skevis, George
    [J]. MEMBRANES, 2021, 11 (04)
  • [32] Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors
    Dindore, VY
    Brilman, DWF
    Geuzebroek, FH
    Versteeg, GF
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) : 133 - 145
  • [33] Insights into a membrane contactor based demonstration unit for CO2 capture
    Nieminen, H.
    Jarvinen, L.
    Ruuskanen, V
    Laari, A.
    Koiranen, T.
    Ahola, J.
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 231
  • [34] Highly Selective Amino Acid Salt Solutions as Absorption Liquid for CO2 Capture in Gas-Liquid Membrane Contactors
    Simons, Katja
    Nijmeijer, Kitty
    Mengers, Harro
    Brilman, Wim
    Wessling, Matthias
    [J]. CHEMSUSCHEM, 2010, 3 (08) : 939 - 947
  • [35] Absorption of CO2 Form Natural Gas via Gas-liquid PVDF Hollow Fiber Membrane Contactor and Potassium Glycinate as Solvent
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    [J]. JURNAL TEKNOLOGI, 2014, 69 (09):
  • [36] MEMBRANE BIOREACTOR WITH A POROUS HYDROPHOBIC MEMBRANE AS A GAS-LIQUID CONTACTOR FOR WASTE-GAS TREATMENT
    REIJ, MW
    DEGOOIJER, KD
    DEBONT, JAM
    HARTMANS, S
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1995, 45 (02) : 107 - 115
  • [37] CO2 removal from a gas stream by membrane contactor
    Bottino, Aldo
    Capannelli, Gustavo
    Comite, Antonio
    Di Felice, Renzo
    Firpo, Raffaella
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 59 (01) : 85 - 90
  • [38] Prediction of CO2/O2 absorption selectivity using supported ionic liquid membranes (SILMs) for gas-liquid membrane contactor
    Ramli, N. Ain
    Hashim, N. Awanis
    Aroua, M. K.
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 2018, 205 (03) : 295 - 310
  • [39] High pressure regeneration of MDEA in membrane gas-liquid contactor
    Bazhenov, S.
    Lysenko, A.
    Dibrov, G.
    Vasilevsky, V.
    Khotimsky, V.
    Volkov, A.
    [J]. EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1185 - 1187
  • [40] Effect of flow configuration on the performance of gas-liquid membrane contactor
    Mavroudi, M.
    Kaldis, S. P.
    Sakellaropoulos, G. P.
    [J]. EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1454 - 1457