Cyclic olefin polymer membrane as an emerging material for CO2 capture in gas-liquid membrane contactor

被引:8
|
作者
Sabzekar, Malihe [1 ]
Chenar, Mahdi Pourafshari [1 ]
Khayet, Mohamed [2 ,3 ]
Garcia-Payo, Carmen [2 ]
Maghsoud, Zahra [1 ]
Pagliero, Marcello [4 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Engn, Dept Chem Engn, Mashhad, Iran
[2] Univ Complutense Madrid, Fac Phys, Dept Struct Matter Thermal Phys & Elect, Avda Complutense S-N, Madrid 28040, Spain
[3] IMDEA Water Inst, Avda Punto Com 2, Alcala De Henares 28805, Madrid, Spain
[4] Univ Genoa, Dept Chem & Ind Chem, Membrane & Membrane Res Grp, Via Dodecaneso 31, I-16146 Genoa, Italy
来源
关键词
Cyclic olefin polymer (COP); Membrane contactor; Porous flat-sheet membrane; Non-solvent induced phase separation; CO2; absorption; OF-THE-ART; PERFORMANCE; ABSORPTION;
D O I
10.1016/j.jece.2024.107669
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Porous flat sheet membranes were prepared with a commercial grade of cyclic olefin polymer (COP) for CO2 capture using membrane contactor (MC). The membranes were prepared via non-solvent induced phase separation technique using different types of additives, namely, polyvinylpyrrolidone (PVP), polyethylene glycol (PEG400) and sorbitan monooleate (Span 80), and coagulants (acetone and 70/30 wt% acetone/water mixture) were investigated. The prepared membranes were characterized in terms of the thickness (70-85 mu m), porosity (50-80%), mean pore size (158-265 nm), bubble pore size (similar to 0.6-12 mu m), liquid entry pressure (1.67-4.55 bar), water contact angle (similar to 94 degrees - 111 degrees), monoethanolamine (MEA) contact angle (similar to 67 degrees - 73 degrees) and mechanical properties (tensile strength: 4.53 - 5.15 MPa, elongation at break: 4 - 8% and Young's modulus: 190 - 232 MPa). The thermodynamic study of COP membranes proved that a fast phase inversion of the proposed system resulted in a more porous structure. The addition of PEG400 and Span 80 caused delayed demixing and influenced the morphological structure and MC performance. The structural and topographical characteristics of the membranes were also studied. The CO2 absorption test performed at 27 degrees C showed that the maximum CO2 absorption flux was around 16 x 10(-5) mol/m(2).s using 1 M MEA aqueous solution as absorbent with fixed liquid and gas flow rates at 150 L/h and 8.4 L/h, respectively. It was found that the considered additives enhanced the MC performance and affected the CO2 absorption flux.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Investigation of membrane wetting for CO2 capture by gas-liquid contactor based on ceramic membrane br
    Xue, Kaili
    Fu, Hongming
    Chen, Haiping
    Zhang, Heng
    Gao, Dan
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 304
  • [2] Development of robust fluorinated TiO2/PVDF composite hollow fiber membrane for CO2 capture in gas-liquid membrane contactor
    Lin, Yuqing
    Xu, Yilin
    Loh, Chun Heng
    Wang, Rong
    [J]. APPLIED SURFACE SCIENCE, 2018, 436 : 670 - 681
  • [3] CO2 stripping from ionic liquid at elevated pressures in gas-liquid membrane contactor
    Bazhenov, Stepan
    Malakhov, Alexander
    Bakhtin, Danila
    Khotimskiy, Valery
    Bondarenko, Galina
    Volkov, Vladimir
    Ramdin, Mahinder
    Vlugt, Thijs J. H.
    Volkov, Alexey
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 71 : 293 - 302
  • [4] Pushing the limits of intensified CO2 post-combustion capture by gas-liquid absorption through a membrane contactor
    Chabanon, E.
    Bounaceur, R.
    Castel, C.
    Rode, S.
    Roizard, D.
    Favre, E.
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2015, 91 : 7 - 22
  • [5] Membrane Contactor as Reactor for CO2 Capture
    Lu, Jian-Gang
    Fan, Fan
    Liu, Cong
    Ji, Yan
    Zhang, Hui
    [J]. INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2011, 9
  • [6] Membrane contactor as reactor for CO2 capture
    Lu, Jian-Gang
    Fan, Fan
    Liu, Cong
    Ji, Yan
    Zhang, Hui
    [J]. International Journal of Chemical Reactor Engineering, 2011, 9
  • [7] PVDF/CaCO3 composite hollow fiber membrane for CO2 absorption in gas-liquid membrane contactor
    Fosi-Kofal, M.
    Mustafa, A.
    Ismail, A. F.
    Rezaei-DashtArzhandi, M.
    Matsuura, T.
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 31 : 428 - 436
  • [8] Gas-liquid membrane contactors for CO2 removal
    Simons, Katja
    Nijmeijer, Kitty
    Wessling, Matthias
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2009, 340 (1-2) : 214 - 220
  • [9] Preparation of nanoparticles with a gas-liquid membrane contactor
    Jia, Zhiqian
    Chang, Qing
    Qin, Jin
    Hong, Xuemin
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2009, 342 (1-2) : 1 - 5
  • [10] A microgrooved membrane based gas-liquid contactor
    Jani, Jigar M.
    Wessling, Matthias
    Lammertink, Rob G. H.
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (03) : 499 - 509