Attenuation correction in hybrid positron emission tomography

被引:14
|
作者
Turkington, TG
机构
[1] Duke Univ, Med Ctr, PET Facil, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
关键词
D O I
10.1053/snuc.2000.9542
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Attenuation effects are more severe for coincidence imaging than for single-photon imaging. The capability to measure and correct attenuation now exists with dedicated positron emission tomography (PET) scanners. Attenuation correction may or may not improve lesion detection in various situations, but it definitely produces a more realistic radioactivity distribution and is essential for quantitation, which is an important PET capability. For hybrid PET systems, though, which are relatively new and in which neither the performance nor the cost of the scanner can be compromised much compared with the conventional nuclear medicine device alone, attenuation correction is still novel. Just as the entire modality of PET imaging on hybrid gamma cameras has expanded very rapidly, the capability to achieve attenuation correction has quickly followed. Both radioactive source-based and x-ray-based systems exist that provide adequate maps for attenuation correction, and the x-ray systems go even further to provide anatomic detail to aid in image interpretation. Copyright (C) 2000 by W.B. Saunders Company.
引用
收藏
页码:255 / 267
页数:13
相关论文
共 50 条
  • [1] ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    NATTERER, F
    HERZOG, H
    [J]. MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 1992, 15 (05) : 321 - 330
  • [2] ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    GODDARD, J
    JACKSON, S
    KENNY, P
    BOLOMEY, L
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 553 - 553
  • [3] A HYBRID METHOD OF ATTENUATION CORRECTION FOR POSITRON EMISSION TOMOGRAPHY BRAIN STUDIES
    BETTINARDI, V
    GILARDI, MC
    CARGNEL, S
    RIZZO, G
    TERAS, M
    STRIANO, G
    FAZIO, F
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (12): : 1279 - 1284
  • [4] Filtered attenuation correction in positron emission tomography
    Demirkaya, O
    Al Mazrou, RY
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 968 - 968
  • [5] Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography
    Pan, Tinsu
    Zaidi, Habib
    [J]. PET CLINICS, 2013, 8 (01) : 37 - +
  • [6] An automatic classification technique for attenuation correction in positron emission tomography
    V. Bettinardi
    E. Pagani
    M. C. Gilardi
    C. Landoni
    C. Riddell
    G. Rizzo
    I. Castiglioni
    D. Belluzzo
    G. Lucignani
    S. Schubert
    F. Fazio
    [J]. European Journal of Nuclear Medicine, 1999, 26 : 447 - 458
  • [7] An automatic classification technique for attenuation correction in positron emission tomography
    Bettinardi, V
    Pagani, E
    Gilardi, MC
    Landoni, C
    Riddell, C
    Rizzo, G
    Castiglioni, I
    Belluzzo, D
    Lucignani, G
    Schubert, S
    Fazio, F
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (05) : 447 - 458
  • [8] NOISE AND INACCURACY INTRODUCED BY ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    CHEN, CT
    BECK, RN
    COOPER, MD
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 470 - 470
  • [9] Hidden Markov model based attenuation correction for positron emission tomography
    Anderson, JMM
    Srinivasan, R
    Mair, BA
    Votaw, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2103 - 2111
  • [10] ATTENUATION CORRECTION IN CARDIAC POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    BACHARACH, SL
    BUVAT, I
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (03) : 246 - 255