An automatic classification technique for attenuation correction in positron emission tomography

被引:61
|
作者
Bettinardi, V
Pagani, E
Gilardi, MC
Landoni, C
Riddell, C
Rizzo, G
Castiglioni, I
Belluzzo, D
Lucignani, G
Schubert, S
Fazio, F
机构
[1] Univ Milan, Dept Nucl Med, Sci Inst H San Raffaele, INB,CNR, I-20132 Milan, Italy
[2] GE, Med Syst, Milwaukee, WI 53201 USA
关键词
attenuation correction; clustering technique; position emission tomography;
D O I
10.1007/s002590050410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper a clustering technique is proposed for attenuation correction (AC) in positron emission tomography (PET). The method is unsupervised and adaptive with respect to counting statistics in the transmission (TR) images. The technique allows the classification of pre- or post-injection TR images into main tissue components in terms of attenuation coefficients. The classified TR images are then forward projected to generate new TR sinograms to be used for AC in the reconstruction of the corresponding emission (EM) data. The technique has been tested on phantoms and clinical data of brain, heart and whole-body PET studies. The method allows: (a) reduction of noise propagation from TR into EM images, (b) reduction of TR scanning to a few minutes (3 min) with maintenance of the quantitative accuracy (within 6%) of longer acquisition scans (15-20 min), (c) reduction of the radiation dose to the patient, (d) performance of quantitative whole-body studies.
引用
收藏
页码:447 / 458
页数:12
相关论文
共 50 条
  • [1] An automatic classification technique for attenuation correction in positron emission tomography
    V. Bettinardi
    E. Pagani
    M. C. Gilardi
    C. Landoni
    C. Riddell
    G. Rizzo
    I. Castiglioni
    D. Belluzzo
    G. Lucignani
    S. Schubert
    F. Fazio
    [J]. European Journal of Nuclear Medicine, 1999, 26 : 447 - 458
  • [2] ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    NATTERER, F
    HERZOG, H
    [J]. MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 1992, 15 (05) : 321 - 330
  • [3] ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    GODDARD, J
    JACKSON, S
    KENNY, P
    BOLOMEY, L
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 553 - 553
  • [4] Filtered attenuation correction in positron emission tomography
    Demirkaya, O
    Al Mazrou, RY
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 968 - 968
  • [5] Attenuation correction in hybrid positron emission tomography
    Turkington, TG
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2000, 30 (04) : 255 - 267
  • [6] Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography
    Pan, Tinsu
    Zaidi, Habib
    [J]. PET CLINICS, 2013, 8 (01) : 37 - +
  • [7] NOISE AND INACCURACY INTRODUCED BY ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY
    CHEN, CT
    BECK, RN
    COOPER, MD
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 470 - 470
  • [8] A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography
    Knesaurek, K
    Machac, J
    Vallabhajosula, S
    Buchsbaum, MS
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06): : 656 - 661
  • [9] Hidden Markov model based attenuation correction for positron emission tomography
    Anderson, JMM
    Srinivasan, R
    Mair, BA
    Votaw, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2103 - 2111
  • [10] A HYBRID METHOD OF ATTENUATION CORRECTION FOR POSITRON EMISSION TOMOGRAPHY BRAIN STUDIES
    BETTINARDI, V
    GILARDI, MC
    CARGNEL, S
    RIZZO, G
    TERAS, M
    STRIANO, G
    FAZIO, F
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (12): : 1279 - 1284