Carbon nanotube filter functionalized with iron oxychloride for flow-through electro-Fenton

被引:139
|
作者
Li, Zizhen [1 ]
Shen, Chensi [1 ,2 ]
Liu, Yanbiao [1 ,2 ]
Ma, Chunyan [1 ]
Li, Fang [1 ,2 ]
Yang, Bo [1 ]
Huang, Manhong [1 ,2 ]
Wang, Zhiwei [2 ,3 ]
Dong, Liming [4 ]
Wolfgang, Sand [1 ,5 ]
机构
[1] Donghua Univ, Coll Environm Sci & Engn, Text Pollut Controlling Engn Ctr, Minist Environm Protect, 2999 North Renmin Rd, Shanghai 201620, Peoples R China
[2] Shanghai Inst Pollut Control & Ecol Secur, 1239 Siping Rd, Shanghai 200092, Peoples R China
[3] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[4] Beijing Technol & Business Univ, Key Lab Cleaner Prod & Integrated Resource Utiliz, Beijing 100048, Peoples R China
[5] Freiberg Univ Min & Technol, Inst Biosci, D-09599 Freiberg, Germany
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
Continuous flow; Electro-Fenton; Iron oxychloride; CNT filter; Tetracycline; WASTE-WATER TREATMENT; ANTIBIOTIC TETRACYCLINE; PHOTO-FENTON; EFFICIENT DEGRADATION; SELECTIVE ADSORPTION; HYDROGEN-PEROXIDE; HYDROXYL RADICALS; ORGANIC-DYES; OXIDATION; PERFORMANCE;
D O I
10.1016/j.apcatb.2019.118204
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Electro-Fenton is a promising advanced oxidation process for the treatment of emerging contaminants from water bodies. Here, we developed a robust and affordable flow-through electro-Fenton process to degrade antibiotic tetracycline. The key component of this technology is an electroactive and porous carbon nanotube filter functionalized with FeOCl. These nanoscale FeOCl significantly promoted the generation of HO center dot by facilitating efficient cycling of Fe3+/Fe2+. Electrochemical filtration of 0.04 mM tetracycline at -0.8 V vs. Ag/AgCl and a flow rate of 1.5 mL min(-1) resulted in an oxidative flux of 5.32 +/- 0.41 mmol h(-1) m(-2). Relative to conventional batch reactor, the proposed system showed enhanced tetracycline degradation kinetics because of the convection-enhanced mass transport. The underlying working mechanism of the system was proposed based on various advanced assessments and density functional theory calculations. This study should offer new insights about the rational design of continuous-flow systems towards efficient removal of various contaminants.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Hemp-ball-like structured Fe 3 O 4-hollow carbon sphere nanozymes functionalized carbon fiber cathode for efficient flow-through electro-Fenton
    Cao, Ting
    Chen, Zhuang
    Zhang, Yimei
    Yang, Mingwang
    Wang, Pengfei
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (04):
  • [22] A novel cost-effective flow-through electrode based on polyacrylonitrile carbon fiber for enhancing micropollutant degradation via electro-Fenton
    Huang, Yu
    Shi, Lin
    Chen, Xiaofei
    Zhu, Liandong
    Mao, Xuhui
    Xu, Tao
    Zhu, Hua
    Wang, Xu
    CHEMICAL ENGINEERING JOURNAL, 2023, 477
  • [23] Enhanced flow-through electro-Fenton process based on rGO aerogel cathode: Essential role of sodium tetrapolyphosphate
    Cheng, Song
    Liu, Yutao
    Shen, Chen
    Jiang, Bicun
    Liu, Fuqiang
    Li, Aimin
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (06):
  • [24] A highly efficient flow-through electro-Fenton system enhanced with nitrilotriacetic acid for phenol removal at neutral pH
    Zhang, Yinqiao
    Zhang, Qizhan
    Zuo, Sijin
    Zhou, Minghua
    Pan, Yuwei
    Ren, Gengbo
    Li, Yanchun
    Zhang, Ying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 697
  • [25] A comparison between flow-through cathode and mixed tank cells for the electro-Fenton process with conductive diamond anode
    Moraleda, I
    Oturan, N.
    Saez, C.
    Llanos, J.
    Rodrigo, M. A.
    Otura, M. A.
    CHEMOSPHERE, 2020, 238
  • [26] A carbon nanotube-confined iron modified cathode with prominent stability and activity for heterogeneous electro-Fenton reactions
    Su, Pei
    Zhou, Minghua
    Ren, Gengbo
    Lu, Xiaoye
    Du, Xuedong
    Song, Ge
    JOURNAL OF MATERIALS CHEMISTRY A, 2019, 7 (42) : 24408 - 24419
  • [27] A novel flow-through dual-system electro-Fenton for boosting PAEs removal efficiency in natural waters
    Wu, Bei
    Jiang, Zhiqiang
    Lei, Weidong
    Sun, Jie
    Chen, Zhi
    CHEMOSPHERE, 2023, 330
  • [28] Study of the performance of a cylindrical flow-through electro-Fenton reactor using different arrangements of carbon felt electrodes: effect of key operating parameters
    Josué Daniel García-Espinoza
    Irma Robles
    Alfonso Durán-Moreno
    Luis A. Godínez
    Environmental Science and Pollution Research, 2022, 29 : 42305 - 42318
  • [29] Continuous flow-through electro-Fenton membrane reactor with Fe-N4-doped carbon membrane as cathode for efficient removal of dimethylacetamide
    Zhu, Yuxuan
    Chen, Zishang
    Wang, Hong
    Ma, Aijing
    Li, Jianxin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 354
  • [30] Study of the performance of a cylindrical flow-through electro-Fenton reactor using different arrangements of carbon felt electrodes: effect of key operating parameters
    Daniel Garcia-Espinoza, Josue
    Robles, Irma
    Duran-Moreno, Alfonso
    Godinez, Luis A.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (28) : 42305 - 42318