Carbon nanotube filter functionalized with iron oxychloride for flow-through electro-Fenton

被引:139
|
作者
Li, Zizhen [1 ]
Shen, Chensi [1 ,2 ]
Liu, Yanbiao [1 ,2 ]
Ma, Chunyan [1 ]
Li, Fang [1 ,2 ]
Yang, Bo [1 ]
Huang, Manhong [1 ,2 ]
Wang, Zhiwei [2 ,3 ]
Dong, Liming [4 ]
Wolfgang, Sand [1 ,5 ]
机构
[1] Donghua Univ, Coll Environm Sci & Engn, Text Pollut Controlling Engn Ctr, Minist Environm Protect, 2999 North Renmin Rd, Shanghai 201620, Peoples R China
[2] Shanghai Inst Pollut Control & Ecol Secur, 1239 Siping Rd, Shanghai 200092, Peoples R China
[3] Tongji Univ, Sch Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai 200092, Peoples R China
[4] Beijing Technol & Business Univ, Key Lab Cleaner Prod & Integrated Resource Utiliz, Beijing 100048, Peoples R China
[5] Freiberg Univ Min & Technol, Inst Biosci, D-09599 Freiberg, Germany
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
Continuous flow; Electro-Fenton; Iron oxychloride; CNT filter; Tetracycline; WASTE-WATER TREATMENT; ANTIBIOTIC TETRACYCLINE; PHOTO-FENTON; EFFICIENT DEGRADATION; SELECTIVE ADSORPTION; HYDROGEN-PEROXIDE; HYDROXYL RADICALS; ORGANIC-DYES; OXIDATION; PERFORMANCE;
D O I
10.1016/j.apcatb.2019.118204
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Electro-Fenton is a promising advanced oxidation process for the treatment of emerging contaminants from water bodies. Here, we developed a robust and affordable flow-through electro-Fenton process to degrade antibiotic tetracycline. The key component of this technology is an electroactive and porous carbon nanotube filter functionalized with FeOCl. These nanoscale FeOCl significantly promoted the generation of HO center dot by facilitating efficient cycling of Fe3+/Fe2+. Electrochemical filtration of 0.04 mM tetracycline at -0.8 V vs. Ag/AgCl and a flow rate of 1.5 mL min(-1) resulted in an oxidative flux of 5.32 +/- 0.41 mmol h(-1) m(-2). Relative to conventional batch reactor, the proposed system showed enhanced tetracycline degradation kinetics because of the convection-enhanced mass transport. The underlying working mechanism of the system was proposed based on various advanced assessments and density functional theory calculations. This study should offer new insights about the rational design of continuous-flow systems towards efficient removal of various contaminants.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Carbon nanotube filter functionalized with MIL-101(Fe) for enhanced flow-through electro-Fenton
    Dai, Yuling
    Yao, Yuan
    Li, Mohua
    Fang, Xiaofeng
    Shen, Chensi
    Li, Fang
    Liu, Yanbiao
    ENVIRONMENTAL RESEARCH, 2022, 204
  • [2] Carbon Nanotube Membrane Stack for Flow-through Sequential Regenerative Electro-Fenton
    Gao, Guandao
    Zhang, Qiaoying
    Hao, Zhenwei
    Vecitis, Chad D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (04) : 2375 - 2383
  • [3] Insights into boosted flow-through electro-Fenton reaction under nanoconfinement
    Mei, Wutong
    Ren, Yifan
    Chen, Quanyuan
    Liu, Meng
    Wang, Xin
    Nanayakkara, Nadeeshani
    Liu, Yanbiao
    APPLIED CATALYSIS B-ENVIRONMENT AND ENERGY, 2025, 371
  • [4] Carbon-based materials in flow-through electro-fenton: Advanced catalyst design, mechanisms and perspectives
    Chen, Junwen
    Ren, Wei
    Zhong, Shuang
    Zhou, Hongyu
    Ma, Tianyi
    Wang, Shaobin
    Duan, Xiaoguang
    CHEMICAL ENGINEERING JOURNAL, 2024, 500
  • [5] Silicate-Enhanced Heterogeneous Flow-Through Electro-Fenton System Using Iron Oxides under Nanoconfinement
    Guo, Dongli
    Liu, Yanbiao
    Ji, Haodong
    Wang, Chong-Chen
    Chen, Bo
    Shen, Chensi
    Li, Fang
    Wang, Yongxia
    Lu, Ping
    Liu, Wen
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (06) : 4045 - 4053
  • [6] Removal of tetracycline by coupling of flow-through electro-Fenton and in-situ regenerative active carbon felt adsorption
    Zhou, Minghua (zhoumh@nankai.edu.cn), 1600, Elsevier B.V., Netherlands (335):
  • [7] A flow-through electro-Fenton process using modified activated carbon fiber cathode for orange II removal
    Jiao, Yongli
    Ma, Liang
    Tian, Yusi
    Zhou, Minghua
    CHEMOSPHERE, 2020, 252
  • [8] Removal of tetracycline by coupling of flow-through electro-Fenton and in-situ regenerative active carbon felt adsorption
    Zhang, Yinqiao
    Zuo, Sijin
    Zhou, Minghua
    Liang, Liang
    Ren, Gengbo
    CHEMICAL ENGINEERING JOURNAL, 2018, 335 : 685 - 692
  • [9] Supported Atomically-Precise Gold Nanoclusters for Enhanced Flow-through Electro-Fenton
    Liu, Fuqiang
    Liu, Yanbiao
    Yao, Qaofeng
    Wang, Yongxia
    Fang, Xiaofeng
    Shen, Chensi
    Li, Fang
    Huang, Manhong
    Wang, Zhiwei
    Sand, Wolfgang
    Xie, Jianping
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (09) : 5913 - 5921
  • [10] Fabrication of FeOCl nanoparticles modified microchannel carbon cathode for flow-through electro-Fenton degradation of refractory organic pollutants
    Wang, Lei
    Wu, Shuai
    Chen, Hui
    Mao, Wei
    Kang, Wenda
    Chen, Shuo
    Yu, Hongtao
    Quan, Xie
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 288