Effect of mechanical vibrations on Coriolis mass flow meters

被引:27
|
作者
Cheesewright, R [1 ]
Belhadj, A [1 ]
Clark, C [1 ]
机构
[1] Brunel Univ, Dept Syst Engn, Uxbridge UB8 3PH, Middx, England
关键词
Coriolis meter; vibrations;
D O I
10.1115/1.1539098
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An analytical study of the response of a simple Coriolis meter subjected to external mechanical vibrations and corresponding finite element studies of three commercially available meters are presented. These show that vibrations produce additional components in the meter sensor signals but that these components are only at the frequency of the vibrations. The results show that errors reported in vibration experiments, using any frequency except the meter drive frequency, are due to failure of the determination of the phase difference between the sensor signals. The results also show that external vibrations at the meter drive frequency produce a meter error regardless of the phase detection algorithm.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 50 条
  • [41] ESTIMATE OF THE EFFECT OF VIBRATIONS ON QUARTZ GRAVITY METERS
    TOBYAS, V
    DIVIS, K
    [J]. STUDIA GEOPHYSICA ET GEODAETICA, 1978, 22 (04) : 336 - 347
  • [42] A Bayesian method for on-line evaluation of uncertainty in measurement of Coriolis flow meters
    Wang, Yunli
    Wang, Sijia
    Deces-Petit, Cyrille
    [J]. MEASUREMENT, 2021, 179
  • [43] Experimental study of oscillatory motion of particles and bubbles with applications to Coriolis flow meters
    Weinstein, J. A.
    Kassoy, D. R.
    Bell, M. J.
    [J]. PHYSICS OF FLUIDS, 2008, 20 (10)
  • [44] Flow measurement in bitter cold: How to use coriolis meters in cryogenic service
    Patten, Tim
    Dunphy, Keven
    [J]. CHEMICAL ENGINEERING, 2006, 113 (07) : 48 - 49
  • [45] Performance evaluation test of Coriolis flow meters for hydrogen metering at high pressure
    Morioka, Toshihiro
    [J]. MEASUREMENT, 2023, 221
  • [46] A simple parametric design model for straight-tube Coriolis flow meters
    Ford, C. L.
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 79
  • [47] Coriolis meters in two phase conditions
    Hemp, J
    Yeung, H
    [J]. COMPUTING & CONTROL ENGINEERING JOURNAL, 2003, 14 (04): : 36 - 36
  • [48] The possibility of application of Coriolis Mass Flow Meters for custody transfer metering related to Small Scale LNG and other cryogenic media
    Roslonek, Grzegorz
    Bogucki, Adam
    Urbanowicz, Adam
    Kowalczyk, Stanislaw
    [J]. NAFTA-GAZ, 2019, (10): : 633 - 639
  • [49] Coriolis mass flow metering with multiphase media
    Rieder, A
    Matt, C
    [J]. SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 381 - 382
  • [50] μ-Coriolis Mass Flow Sensor with Resistive Readout
    Schut, Thomas
    Wiegerink, Remco
    Lotters, Joost
    [J]. MICROMACHINES, 2020, 11 (02)