Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum

被引:6
|
作者
Chua, Weiliang [1 ]
Roy, Shuvendu [1 ]
Sng, Jonathan [1 ]
Liang, Shen [1 ]
Das De, Shamal [1 ]
机构
[1] Natl Univ Singapore Hosp, Singapore 119074, Singapore
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2014年 / 22卷 / 03期
关键词
arthroplasty; replacement; hip; osteolysis; polyethylene; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; FOLLOW-UP; WEAR; ARTHROPLASTY; OSTEOLYSIS; ASSOCIATION; COMPONENTS; REVISION; QUALITY;
D O I
10.1177/230949901402200315
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. Methods. Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n= 26), avascular necrosis (n= 26), osteoarthritis (n= 22), rheumatoid arthritis (n= 4), and ankylosing spondylitis (n= 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. Results. After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean +/- standard deviation femoral head penetration was 0.29 +/- 0.12 mm (or 0.04 +/- 0.02 mm/year) by the PowerPoint method and 0.17 +/- 0.22 mm (or 0.02 +/- 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p= 0.012). Conclusion. The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [31] A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty
    Mu, Zongyou
    Tian, Jialiang
    Wu, Taixiang
    Yang, Jing
    Pei, Fuxing
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 599 - 604
  • [32] A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty
    Zongyou Mu
    Jialiang Tian
    Taixiang Wu
    Jing Yang
    Fuxing Pei
    International Orthopaedics, 2009, 33 : 599 - 604
  • [33] Poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liner in primary total hip replacement: one-year results of a prospective cohort study
    Takatori, Yoshio
    Moro, Toru
    Kamogawa, Morihide
    Oda, Hiromi
    Morimoto, Shuhei
    Umeyama, Takashige
    Minami, Manabu
    Sugimoto, Hideharu
    Nakamura, Shigeru
    Karita, Tatsuro
    Kim, Juntaku
    Koyama, Yurie
    Ito, Hideya
    Kawaguchi, Hiroshi
    Nakamura, Kozo
    JOURNAL OF ARTIFICIAL ORGANS, 2013, 16 (02) : 170 - 175
  • [34] The Use of Highly Cross-linked Polyethylene in Total Knee Arthroplasty
    Lachiewicz, Paul F.
    Geyer, Mark R.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (03) : 143 - 151
  • [35] Manufacturing, oxidation, mechanical properties and clinical performance of highly cross-linked polyethylene in total hip arthroplasty
    Singh, Gurpreet
    Klassen, Robert
    Howard, James
    Naudie, Douglas
    Teeter, Matthew
    Lanting, Brent
    HIP INTERNATIONAL, 2018, 28 (06) : 573 - 583
  • [36] Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Samujh, Christopher
    Bhimani, Samrath
    Smith, Langan
    Malkani, Arthur L.
    ORTHOPEDICS, 2016, 39 (06) : E1178 - E1182
  • [37] Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial
    Salemyr, Mats
    Muren, Olle
    Ahl, Torbjorn
    Boden, Henrik
    Chammout, Ghazi
    Stark, Andre
    Skoldenberg, Olof
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (08) : 1499 - 1505
  • [38] Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial
    Mats Salemyr
    Olle Muren
    Torbjörn Ahl
    Henrik Bodén
    Ghazi Chammout
    André Stark
    Olof Sköldenberg
    International Orthopaedics, 2015, 39 : 1499 - 1505
  • [39] Cementation of the highly cross-linked polyethylene liner into a well-fixed acetabular shell to treat patients with recurrent dislocation after total hip arthroplasty
    Wang, Pai-Han
    Tsai, Shang-Wen
    Chen, Cheng-Fong
    Wu, Po-Kuei
    Chen, Chao-Ming
    Chang, Ming-Chau
    Chen, Wei-Ming
    ARTIFICIAL ORGANS, 2021, 45 (05) : E136 - E145
  • [40] Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years
    Pritchett, James W.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10): : 2203 - 2208