Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum

被引:6
|
作者
Chua, Weiliang [1 ]
Roy, Shuvendu [1 ]
Sng, Jonathan [1 ]
Liang, Shen [1 ]
Das De, Shamal [1 ]
机构
[1] Natl Univ Singapore Hosp, Singapore 119074, Singapore
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2014年 / 22卷 / 03期
关键词
arthroplasty; replacement; hip; osteolysis; polyethylene; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; FOLLOW-UP; WEAR; ARTHROPLASTY; OSTEOLYSIS; ASSOCIATION; COMPONENTS; REVISION; QUALITY;
D O I
10.1177/230949901402200315
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. Methods. Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n= 26), avascular necrosis (n= 26), osteoarthritis (n= 22), rheumatoid arthritis (n= 4), and ankylosing spondylitis (n= 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. Results. After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean +/- standard deviation femoral head penetration was 0.29 +/- 0.12 mm (or 0.04 +/- 0.02 mm/year) by the PowerPoint method and 0.17 +/- 0.22 mm (or 0.02 +/- 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p= 0.012). Conclusion. The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [1] Linear Wear Rates of a Highly Cross-Linked Polyethylene Hip Liner
    Sodhi, Nipun
    Newman, Jared M.
    Khlopas, Anton
    Jaggard, Charles
    Sultan, Assem A.
    Mont, Michael A.
    Kolisek, Frank
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2018, 33
  • [2] Durability of Highly Cross-Linked Polyethylene in Total Hip and Total Knee Arthroplasty
    Dion, Neil T.
    Bragdon, Charles
    Muratoglu, Orhun
    Freiberg, Andrew A.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 321 - +
  • [3] Influence of liner offset and locking mechanism on fatigue durability in highly cross-linked polyethylene total hip prostheses
    Kamada, Kosuke
    Takahashi, Yasuhito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Masaoka, Toshinori
    Pezzotti, Giuseppe
    Yamamoto, Kengo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (05) : 1993 - 2004
  • [4] Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years
    Dorr, LD
    Wan, ZN
    Shahrdar, C
    Sirianni, L
    Boutary, M
    Yun, A
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08): : 1816 - 1821
  • [5] Ceramic on highly cross-linked polyethylene in cementless total hip arthroplasty
    Kong, J. -S.
    Moon, K. -H.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2007, : 67 - 70
  • [6] Midterm Results of Primary Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene
    Lee, Ji-Ho
    Lee, Byung Woo
    Lee, Byoung-Joo
    Kim, Shin-Yoon
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1014 - 1019
  • [7] Highly cross-linked polyethylene in total hip arthroplasty, present and future
    Mori, Toshiharu
    Tsukamoto, Manabu
    ANNALS OF JOINT, 2018, 3 (08):
  • [8] SECOND-GENERATION HIGHLY CROSS-LINKED POLYETHYLENE IN TOTAL HIP ARTHROPLASTY
    Parekh, Amit
    Sood, Anshum
    Monsef, Jad Bou
    Hamouda, Mohammed
    Hussain, Awais
    Gonzalez, Mark
    JBJS REVIEWS, 2021, 9 (04)
  • [9] Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty
    Tower, Stephen S.
    Currier, John H.
    Currier, Barbara H.
    Lyford, Kimberly A.
    Van Citters, Douglas W.
    Mayor, Michael B.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10): : 2212 - 2217
  • [10] Total hip replacements with bearings with cross-linked polyethylene
    Trebse, Rihard
    Kovac, Simon
    Berce, Ales
    Pukl, Miha
    Milosev, Ingrid
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2009, 78 : 21 - 33