Measurement of dose enhancement by neutron capture of boron in 252Cf interstitial brachytherapy

被引:1
|
作者
Abd El-Hafez, AI [1 ]
Eissa, HM
Eman, SA
Fadel, MA
机构
[1] Natl Inst Stand, Ionizing Radiat Dept, Giza, Egypt
[2] Cairo Univ, Dept Biophys, Giza, Egypt
关键词
BNCT; interstitial brachytherapy; Cf-252; dose enhancement; neutron therapy;
D O I
10.1016/S1350-4487(97)00117-0
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The effect of boron concentration in water on the gamma, fast and slow neutrons and alpha particles components at the central, forward and backward surfaces inside tumor phantom of 4.2cm diameter and 4.4cm height, during brachytherapy by neutrons from Cf-252 were investigated. The source was at the centre of a cubic shaped water phantom of 30 cm side. The study was carried for different concentrations of boron from H3BO3, Li2B4O7 and (H3BO3)-B-10. The effect of source to tumor distance on the different components of radiation was also measured. The results indicated that the use of B-10 compounds enhances the damage and is recommended for successful boron neutron capture therapy (BNCT).
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [21] The clinical practice of 252Cf neutron brachytherapy devices on malignant tumor in China
    Lei Xin1
    2.Linden Neutron Brachytherapy Center
    3.Shenzhen Zunrua Science & Technology Co.
    Engineering Sciences, 2009, 7 (04) : 51 - 60
  • [22] Dosimetry for 252Cf neutron emitting brachytherapy sources: Protocol, measurements, and calculations
    Department of Radiation Oncology, Tufts University School of Medicine, New England Medical Center, #246, 750 Washington Street, Boston, MA 02111, United States
    Med. Phys., 8 (1503-1514):
  • [23] Burst calculations for 252Cf brachytherapy sources
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2816 - 2820
  • [24] Neutron absorbed dose rate with 252Cf sources for medical applications
    Paredes, L.
    Azorin, J.
    Balcazar, M.
    Francois, J. L.
    REVISTA MEXICANA DE FISICA, 2010, 56 (01) : 44 - 46
  • [25] Derivation of the relative biological effectiveness of high dose rate 252Cf brachytherapy
    Rivard, M
    Zinkin, H
    Melhus, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2063 - 2063
  • [26] 157Gd photon dose enhancement from a neutron emitting 252Cf point source
    Rivard, MJ
    Yudelev, M
    Wierzbicki, JG
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1211 - 1217
  • [27] Treatment planning for interstitial, and intracavitary Cf-252 neutron brachytherapy
    Miller, A
    Atkocine, E
    Kersuliene, M
    Atkocius, V
    CALIFORNIUM-252: ISOTOPE FOR 21ST CENTURY RADIOTHERAPY, 1997, 29 : 211 - 219
  • [28] THERMAL-NEUTRON CAPTURE CROSS SECTION AND RESONANCE INTEGRAL OF 252CF
    HALPERIN, J
    BEMIS, CE
    DRUSCHEL, RE
    STOKELY, JR
    NUCLEAR SCIENCE AND ENGINEERING, 1969, 37 (02) : 228 - &
  • [29] Neutron brachytherapy adenocarcenoma of corpus uteri with usage of high activity 252Cf sources
    Marjina, LA
    Chekhonadsky, VN
    Nechushkin, MI
    INTERNATIONAL JOURNAL OF CANCER, 2002, : 383 - 383
  • [30] Dosimetric effects of composition, location and size of tissue heterogeneities on 252Cf neutron brachytherapy
    Karimi-Shahri, Keyhandokht
    Izadi-Vasafi, Gholam Hossein
    Firoozabadi, Mohammad Mehdi
    Ghorbani, Mahdi
    APPLIED RADIATION AND ISOTOPES, 2021, 171