Evaluation of efficacy of a new custom-made pulse oximeter dental probe in comparison with the electrical and thermal tests for assessing pulp vitality

被引:77
|
作者
Gopikrishna, Velayutham [1 ]
Dnagupta, Kush [1 ]
Kandaswamy, Deivanayagam [1 ]
机构
[1] Meenakshi Ammal Dent Coll, Dept Conservat Dent & Endodont, Madras 600095, Tamil Nadu, India
关键词
pulp vitality; pulse oximeter; pulse oximeter dental sensor holder;
D O I
10.1016/j.joen.2006.12.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Pulse oximetry is a noninvasive method of measuring vascular health by evaluating oxygen saturation. This study evaluated the efficacy of a new custom-made pulse oximeter dental probe in comparison with the electrical and thermal tests for assessing pulp vitality. Sensitivity, specificity, negative predictive value, and positive predictive value for each test were calculated by comparing the test results with the actual pulpal status, as evaluated by direct visual inspection. The sensitivity of the pulse oximeter was found to be 1.00, as compared to 0.81 with the cold test and 0.71 with the electrical test. The specificity of the pulse oximeter was 0.95, as compared to 0.92 with the cold and electrical pulp tests. Thus, the custom-made pulse oximeter dental probe is an effective, accurate, and objective method of evaluating pulp vitality.
引用
收藏
页码:411 / 414
页数:4
相关论文
共 7 条
  • [1] Comparison of the Efficacy of a Custom-made Pulse Oximeter Probe with Digital Electric Pulp Tester, Cold Spray, and Rubber Cup for Assessing Pulp Vitality
    Dastmalchi, Nafiseh
    Jafarzadeh, Hamid
    Moradi, Saeed
    JOURNAL OF ENDODONTICS, 2012, 38 (09) : 1182 - 1186
  • [2] Evaluation of a pulse oximeter and customized probe for pulp vitality testing
    Kahan, RS
    Gulabivala, K
    Snook, M
    Setchell, DJ
    JOURNAL OF ENDODONTICS, 1996, 22 (03) : 105 - 109
  • [3] Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status
    Janani, Krishnamachari
    Ajitha, P.
    Sandhya, Raghu
    Subbaiyan, Haripriya
    Jose, Jerry
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (07) : 3333 - 3337
  • [4] In Vivo Evaluation of Customized Pulse Oximeter and Sensitivity Pulp Tests for Assessment Of Pulp Vitality
    Sharma, Divya S.
    Mishra, Shikha
    Banda, Naveen Reddy
    Vaswani, Sneha
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2019, 43 (01) : 11 - 15
  • [5] Comparison of electrical, thermal, and pulse oximetry methods for assessing pulp vitality in recently traumatized teeth
    Gopikrishna, Velayutham
    Tinagupta, Kush
    Kandaswamy, Deivanayagam
    JOURNAL OF ENDODONTICS, 2007, 33 (05) : 531 - 535
  • [6] Evaluation of the ability of thermal and electrical tests to register pulp vitality
    Petersson, K
    Söderström, C
    Kiani-Anaraki, M
    Lévy, G
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1999, 15 (03): : 127 - 131
  • [7] Evaluation of flat ridge rehabilitation using an intraoral custom-made distraction device at four weeks versus eight weeks and its impact on dental implant efficacy: A comparative study
    Hassan, Sherif S.
    Shuman, Mohamed A.
    Makke, Alaa Z.
    Alqutub, Alaa W.
    Bamaga, Ibraheem K.
    Nofal, Reda A.
    Al-Kabany, Mohammed H.