Comparison of electrical, thermal, and pulse oximetry methods for assessing pulp vitality in recently traumatized teeth

被引:81
|
作者
Gopikrishna, Velayutham [1 ]
Tinagupta, Kush [1 ]
Kandaswamy, Deivanayagam [1 ]
机构
[1] Meenakshi Ammal Dent Coll, Dept Conservat Dent & Endodont, Madras 600095, Tamil Nadu, India
关键词
pulp vitality; pulse oximeter; pulse oximeter dental sensor holder; traumatized permanent teeth;
D O I
10.1016/j.joen.2007.01.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Pulse oximeter is a well-established and noninvasive method for measuring vascular health by evaluating oxygen saturation. This study compared the efficacy of a custom-made pulse oximeter dental probe with the electric pulp testing and thermal testing for measuring pulp vitality status of recently traumatized permanent teeth. Readings for pulp vitality for 17 recently traumatized maxillary incisors were taken with custom made pulse oximeter dental probe (group 1), electrical pulp tester (group 2), and thermal testing (group 3) over a 6-month period. The proportion of recently traumatized teeth showing a positive responsiveness in thermal/electric pulp tests increased from no teeth showing responsiveness on day 0 to 29.4% teeth on the 28th day, 82.35% of teeth at 2 months, and 94.11% teeth at 3 months. However, pulse oximeter gave positive vitality readings that remained constant over the study period from day 0 to 6 months in all patients.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [1] Pulse oximetry: a useful test for evaluating pulp vitality in traumatized teeth
    Caldeira, Celso Luiz
    Barletta, Fernando Branco
    Ilha, Mariana Cezar
    Abrao, Carmen Vianna
    Gavini, Giulio
    DENTAL TRAUMATOLOGY, 2016, 32 (05) : 385 - 389
  • [2] Comparison of the reliability of laser Doppler flowmetry, pulse oximetry and electric pulp tester in assessing the pulp vitality of human teeth
    Karayilmaz, H.
    Kirzioglu, Z.
    JOURNAL OF ORAL REHABILITATION, 2011, 38 (05): : 340 - 347
  • [3] The use of pulse oximetry in evaluation of pulp vitality in immature permanent teeth
    Bargrizan, Majid
    Ashari, Mohammad Asna
    Ahmadi, Mohsen
    Ramezani, Jamileh
    DENTAL TRAUMATOLOGY, 2016, 32 (01) : 43 - 47
  • [4] PULSE OXIMETRY - A METHOD OF VITALITY TESTING FOR TEETH
    MILLS, RW
    BRITISH DENTAL JOURNAL, 1992, 172 (09) : 334 - 335
  • [5] Determination of pulp vitality in vivo with pulse oximetry
    Calil, E.
    Caldeira, C. L.
    Gavini, G.
    Lemos, E. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (09) : 741 - 746
  • [6] Vitality Tests for Pulp Diagnosis of Traumatized Teeth: A Systematic Review
    Rocha Lima, Thiago Farias
    dos Santos, Samara Luize
    da Silva Fidalgo, Tatiana Kelly
    Nogueira Leal Silva, Emmanuel Joao
    JOURNAL OF ENDODONTICS, 2019, 45 (05) : 490 - 499
  • [7] Efficacy of Ultrasound Doppler Flowmetry in Assessing Pulp Vitality of Traumatized Teeth: A Propensity Score Matching Analysis
    Ahn, So-Yeon
    Kim, Dohyun
    Park, Sung-Ho
    JOURNAL OF ENDODONTICS, 2018, 44 (03) : 379 - 383
  • [8] LASER DOPPLER FLOWMETRY IN ASSESSING VITALITY IN TRAUMATIZED PERMANENT TEETH
    GAZELIUS, B
    OLGART, L
    LINDHSTROMBERG, U
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1988, 7 : S91 - S91
  • [9] The effect of pulp obliteration on pulpal vitality of orthodontically intruded traumatized teeth
    Bauss, Oskar
    Roehling, Johannes
    Rahman, Alexander
    Kiliaridis, Stavros
    JOURNAL OF ENDODONTICS, 2008, 34 (04) : 417 - 420
  • [10] Determination of pulse-oximetry efficiency as a noninvasive method of assessing dental pulp vitality in children
    Esian, D.
    Jurca, A.
    Bica, C.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2015, 45 : 84 - 84