Turbulence measurements in an axial rotary blood pump with laser Doppler velocimetry

被引:9
|
作者
Schuele, Chan Y. [1 ]
Affeld, Klaus [1 ]
Kossatz, Max [1 ]
Paschereit, Christian O. [2 ]
Kertzscher, Ulrich [1 ]
机构
[1] Charite, Biofluid Mech Lab, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Tech Univ Berlin, Chair Fluid Dynam, Hermann Fottinger Inst, Berlin, Germany
来源
关键词
Enlarged model; HeartMate II; Kolmogorov scale; LDV; Turbulence; SHEAR-STRESS; FLOW; HEMOLYSIS; DAMAGE; LAMINAR;
D O I
10.5301/ijao.5000571
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The implantation of rotary blood pumps as ventricular assist devices (VADs) has become a viable therapy for quite a number of patients with end-stage heart failure. However, these rotary blood pumps cause adverse events that are related to blood trauma. It is currently believed that turbulence in the pump flow plays a significant role. But turbulence has not been measured to date because there is no optical access to the flow space in rotary blood pumps because of their opaque casings. Methods: This difficulty is overcome with a scaled-up model of the HeartMate II (HM II) rotary blood pump with a transparent acrylic housing. A 2-component laser Doppler velocimetry (LDV) system was used for the measurement of time resolved velocity profiles and velocity spectra upstream and downstream of the rotor blades. Observing similarity laws, the speed and pump head were adjusted to correspond closely to the design point of the original pump -10,600 rpm speed and 80 mmHg pressure head. A model fluid consisting of a water-glycerol mixture was used. Results: The measured velocity spectra were scalable by the Kolmogorov length and the Kolmogorov length was estimated to be between 14 and 24 mu m at original scale, thus being about 1.5 to 3 times the size of a red blood cell. Conclusions: It can be concluded that turbulence is indeed present in the investigated blood pump and that it can be described by Kolmogorov's theory of turbulence. The size of the smallest vortices compares well to the turbulence length scales as found in prosthetic heart valves, for example.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [31] Bragg cell laser intensity modulation: effect on laser Doppler velocimetry measurements
    Mychkovsky, Alexander G.
    Chang, Natasha A.
    Ceccio, Steven L.
    APPLIED OPTICS, 2009, 48 (18) : 3468 - 3474
  • [32] TURBULENCE MEASUREMENTS IN A FOUR-VALVE SPARK-IGNITION ENGINE USING LASER-DOPPLER VELOCIMETRY.
    Liou, T.M.
    Chung-Kuo Chi Hsueh Kung Ch'eng Hsueh Pao/Journal of the Chinese Society of Mechanical Engineers, 1984, 5 (02): : 23 - 30
  • [33] LASER DOPPLER VELOCIMETRY INVESTIGATION OF THE TURBULENCE STRUCTURE OF AXISYMMETRIC DIFFUSION FLAMES.
    Sislian, J.P.
    Jiang, L.-Y.
    Cusworth, R.A.
    UTIAS Report (University of Toronto, Institute for Aerospace Studies), 1986,
  • [34] Laser doppler anemometer measurements of the flow in the impeller blade channels of a centrifugal blood pump
    School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
    Hong Kong Inst Eng Trans, 2008, 4 (11-16):
  • [35] Compact system for in situ laser Doppler velocimetry of blood flow
    Bou, Elise
    Ly, Aliou
    Roul, Julien
    Llopis, Olivier
    Vieu, Christophe
    Cerf, Aline
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (11): : 5862 - 5876
  • [36] LASER DOPPLER VELOCIMETRY IN BLOOD AND MULTIPLY SCATTERING FLUIDS - THEORY
    STERN, MD
    APPLIED OPTICS, 1985, 24 (13): : 1968 - 1986
  • [37] LASER DOPPLER VELOCIMETRY OF TRACHEAL BLOOD-FLOW IN SHEEP
    LIN, VW
    KRAMER, GC
    PARSONS, GH
    CROSS, CE
    RESPIRATION PHYSIOLOGY, 1991, 85 (03): : 341 - 354
  • [38] LASER DOPPLER VELOCIMETRY AND THE MEASUREMENT OF COLOSTOMY BLOOD-FLOW
    BILLINGS, PJ
    LEAPER, DJ
    DISEASES OF THE COLON & RECTUM, 1987, 30 (05) : 376 - 380
  • [39] DOPPLER-LASER ANEMOMETER FOR TURBULENCE MEASUREMENTS IN FLUIDS
    GOUESBET, G
    TRINITE, M
    REVUE DE PHYSIQUE APPLIQUEE, 1974, 9 (03): : 571 - 574
  • [40] Application of non-contact laser Doppler velocimetry in measurement of intestinal blood flow: A comparison with contact laser Doppler velocimetry.
    Sakai, M
    Oohata, Y
    Hotokezaka, M
    Ishikawa, M
    Mibu, R
    Tanaka, M
    GASTROENTEROLOGY, 1997, 112 (04) : A399 - A399