Analysis of quasicontinuous radon monitor response

被引:1
|
作者
Lenzen, M
Neugebauer, HJ
机构
[1] Univ Sydney, Sch Phys, Dept Appl Phys, Sydney, NSW 2006, Australia
[2] Univ Bonn, D-53115 Bonn, Germany
来源
HEALTH PHYSICS | 1998年 / 74卷 / 01期
关键词
radon; monitors; sampling; thoron;
D O I
10.1097/00004032-199801000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Continuous radon monitors respond quickly to changes in radon concentration but bear uncertainties due to the fact that the radon concentration in the detector changes within a counting interval, This disadvantage can be overcome by applying quasicontinuous sampling, where the detector chamber is sealed after the sample has been drawn, so that the radon concentration does not change while counting, The chamber is usually kept closed for 15 min or longer and subsequently flushed or evacuated before the new sample is taken. This paper presents a forward-marching algorithm suitable for the analysis of the response of quasicontinuous radon monitors. The method can be used to obtain both Rn-222 and Rn-220 concentrations in the gas sample.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [21] Novel panorama megasize environmental radon monitor
    Sohrabi, M.
    Ghahremani, M.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 181
  • [22] RADON-IMMUNE AIR MONITOR FOR PLUTONIUM
    GUPTON, ED
    HEALTH PHYSICS, 1984, 46 (01): : 217 - 224
  • [23] Radon monitor calibration using NIST radon emanation standards: Steady flow method
    Kotrappa, P
    Stieff, LR
    Volkovitsky, P
    RADIATION PROTECTION DOSIMETRY, 2005, 113 (01) : 70 - 74
  • [24] A HUMIDITY CONTROL TECHNIQUE BASED ON NAFION MEMBRANE AND ITS APPLICATION ON THE EVALUATION OF HUMIDITY RESPONSE FOR RADON MONITOR
    Mao, Yucai
    Wang, Yunxiang
    Zhang, Lei
    Guo, Qiuju
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (3-4) : 448 - 452
  • [25] Theoretical and experimental study of the LR-115 detector response in a non-commercial radon monitor
    Perez, B.
    Lopez, M. E.
    Palacios, D.
    APPLIED RADIATION AND ISOTOPES, 2020, 160
  • [26] A self-calibrating radon monitor with statistical discrimination
    Valcov, N
    Purghel, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3): : 807 - 813
  • [27] Upgrade of a Highly Sensitive Monitor for Atmospheric Radon Measurement
    Zhang, Lei
    Mao, Yucai
    Wang, Hao
    Guo, Qiuju
    ATMOSPHERE, 2021, 12 (10)
  • [28] Industrial commercial respirator filter as indoor radon monitor
    Espinosa, G.
    Silva, R. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) : 405 - 408
  • [29] Modification of the RGR monitor of radon daughters concentration in air
    Machaj, B
    NUKLEONIKA, 1999, 44 (03) : 479 - 490
  • [30] Rapid determination of radon monitor’s calibration factors
    Zhi-Qiang Li
    De-Tao Xiao
    Gui-Zhi Zhao
    Xi-Jun Wu
    Jian Shan
    Qing-Zhi Zhou
    Zheng-Zhong He
    Nuclear Science and Techniques, 2016, 27