Scintillator-based fiber optic dosimeters for electron beam processing

被引:0
|
作者
Hoyt, AE [1 ]
Gosau, JM [1 ]
Harrah, LA [1 ]
Allred, RE [1 ]
机构
[1] Adherent Technol Inc, Albuquerque, NM 87123 USA
关键词
e-beam curing; quality control; radiation sensors;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In our continuing work on fiber-optic dosimeters for electron beam processing of composites, Adherent Technologies, Inc. has developed a series of radiation dosimeters utilizing a polymeric scintillator cladding as the radiation measurement method. These dosimeters are easily incorporated into par's or tools and have the advantage that connection to the readout electronics is through a non-conductive fiber optic lead allowing for remote, real-time readout, which is unaffected by charge deposition or build-up in the target. Real-time monitoring allows in-process monitoring capability required to control laminate cure levels for secondary e-beam bonding or curing with other partial or fully cured laminates. An exact correlation between scintillator signal and deposited dose can be developed The degree of cure will be determined by the substrate specific empirical relationship of accumulated dose and statistically valid thermal glass transition values. These dosimeters can be used in the development of automated cure cycles that control the degree of laminate and bond line cure.
引用
下载
收藏
页码:1855 / 1862
页数:6
相关论文
共 50 条
  • [21] Characterizing the response of a scintillator-based detector to single electrons
    Sang, Xiahan
    LeBeau, James M.
    ULTRAMICROSCOPY, 2016, 161 : 3 - 9
  • [22] Lens design challenges for scintillator-based neutron imaging
    Geppert-Kleinrath, V.
    Tafoya, L.
    Danly, C.
    Fatherley, V.
    Mendoza, E.
    Vaughan, J.
    Wilde, C.
    Volegov, P.
    RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XIX, 2018, 10763
  • [23] A scintillator-based particle detector for CRYRING@ESR
    Hahn, Christoph
    Menz, Esther
    Pfaefflein, Philip
    Weber, Guenter
    Stoehlker, Thomas
    X-RAY SPECTROMETRY, 2020, 49 (02) : 338 - 341
  • [24] Determining the muon mass using a scintillator-based detector
    Woo, Neal
    Essick, John
    AMERICAN JOURNAL OF PHYSICS, 2017, 85 (08) : 611 - 618
  • [25] Simulation of a scintillator-based Compton telescope with micropattern readout
    Varner, Robert. L.
    Beene, James. R.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1248 - 1254
  • [26] Scintillator-based detectors for dark matter searches I
    Kim, S. K.
    Kim, H. J.
    Kim, Y. D.
    NEW JOURNAL OF PHYSICS, 2010, 12
  • [27] Photo image processing analysis of electron beam irradiation on a new liquid scintillator based on alcohol
    Choi, J. Y.
    Joo, K. K.
    Kim, B. C.
    Park, J. B.
    PHYSICA SCRIPTA, 2021, 96 (04)
  • [28] Scintillator-based fast ion loss measurements in the EAST
    Chang, J. F.
    Isobe, M.
    Ogawa, K.
    Huang, J.
    Wu, C. R.
    Xu, Z.
    Jin, Z.
    Lin, S. Y.
    Hu, L. Q.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [29] CASTER - a scintillator-based Black Hole Finder Probe
    Paciesas, WS
    Case, G
    Cherry, ML
    Cravens, J
    Guzik, TG
    Hurley, K
    Kippen, RM
    Ryan, JM
    Macri, JM
    McConnell, ML
    Miller, RS
    Schaefer, BE
    Stacy, JG
    Wefel, JR
    Vestrand, WT
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 417 - 421
  • [30] CASTER - a scintillator-based black hole finder probe
    McConnell, ML
    Cherry, ML
    Guzik, TG
    Kippen, RM
    Ryan, JM
    Macri, JM
    Miller, RS
    Paciesas, WS
    Schaefer, BE
    Stacy, JG
    Wefel, JP
    Vestrand, WT
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 944 - 955