Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases

被引:5
|
作者
Bae, Yun Jung [1 ]
Choi, Byung Se [1 ]
Lee, Kyung Mi [2 ]
Yoon, Yeon Hong [1 ]
Sunwoo, Leonard [1 ]
Jung, Cheolkyu [1 ]
Kim, Jae Hyoung [1 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Radiol, 82 Gumi Ro 173Beon Gil, Seongnam 13620, South Korea
[2] Kyung Hee Univ, Coll Med, Kyung Hee Univ Hosp, Dept Radiol, Seoul 02447, South Korea
关键词
Brain; Neoplasm metastasis; Magnetic resonance imaging; 3; tesla; PULMONARY NODULES; STEREOTACTIC RADIOSURGERY; IMAGES; OBSERVER; CT; ACQUISITION; IMSDE;
D O I
10.3348/kjr.2017.18.4.699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm images of iMSDE-TSE (non-MIP iMSDE-TSE), 1-mm contrast-enhanced 3D T1-weighted gradient-echo imaging (non-MIP 3D-GRE), and 5-mm MIP 3D-GRE. Materials and Methods: From October 2014 to July 2015, 30 patients with 460 enhancing brain metastases (size > 3 mm, n = 150; size = 3 mm, n = 310) were scanned with non-MIP iMSDE-TSE and non-MIP 3D-GRE. We then performed 5-mm MIP reconstruction of these images. Two independent neuroradiologists reviewed these four sequences. Their diagnostic performance was compared using the following parameters: sensitivity, reading time, and figure of merit (FOM) derived by jackknife alternative free-response receiver operating characteristic analysis. Interobserver agreement was also tested. Results: The mean FOM (all lesions, 0.984; lesions = 3 mm, 0.980) and sensitivity ([reader 1: all lesions, 97.3%; lesions = 3 mm, 96.2%], [reader 2: all lesions, 97.0%; lesions = 3 mm, 95.8%]) of MIP iMSDE-TSE was comparable to the mean FOM (0.985, 0.977) and sensitivity ([reader 1: 96.7, 99.0%], [reader 2: 97, 95.3%]) of non-MIP iMSDE-TSE, but they were superior to those of non-MIP and MIP 3D-GREs (all, p < 0.001). The reading time of MIP iMSDE-TSE (reader 1: 47.7 +/- 35.9 seconds; reader 2: 44.7 +/- 23.6 seconds) was significantly shorter than that of non-MIP iMSDE-TSE (reader 1: 78.8 +/- 43.7 seconds, p = 0.01; reader 2: 82.9 +/- 39.9 seconds, p < 0.001). Interobserver agreement was excellent (kappa > 0.75) for all lesions in both sequences. Conclusion: MIP iMSDE-TSE showed high detectability of brain metastases. Its detectability was comparable to that of non-MIP iMSDE-TSE, but it was superior to the detectability of non-MIP/MIP 3D-GREs. With a shorter reading time, the false-positive results of MIP iMSDE-TSE were greater. We suggest that MIP iMSDE-TSE can provide high diagnostic performance and low false-positive rates when combined with 1-mm sequences.
引用
收藏
页码:699 / 709
页数:11
相关论文
共 28 条
  • [21] High Resolution Diffusion-Weighted Imaging for Solitary Orbital Tumors3D Turbo Field Echo with Diffusion-Sensitized Driven-Equilibrium (DSDE-TFE) Preparation Technique
    Akio Hiwatashi
    Osamu Togao
    Koji Yamashita
    Kazufumi Kikuchi
    Hiroshi Yoshikawa
    Makoto Obara
    Hiroshi Honda
    Clinical Neuroradiology, 2018, 28 : 261 - 266
  • [22] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [23] 3D Fast Spin-Echo T1Black-Blood Imaging for the Preoperative Detection of Venous Sinus Invasion by Meningioma: Comparison with Contrast-Enhanced MRV
    Wang, Dongdong
    Lu, Yiping
    Yin, Bo
    Chen, Mingyu
    Geng, Daoying
    Liu, Li
    Wen, Jianbo
    Zhong, Ping
    Li, Yuan
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 65 - 73
  • [24] 3D Fast Spin-Echo T1 Black-Blood Imaging for the Preoperative Detection of Venous Sinus Invasion by MeningiomaComparison with Contrast-Enhanced MRV
    Dongdong Wang
    Yiping Lu
    Bo Yin
    Mingyu Chen
    Daoying Geng
    Li Liu
    Jianbo Wen
    Ping Zhong
    Yuan Li
    Clinical Neuroradiology, 2019, 29 : 65 - 73
  • [25] The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI
    Parillo, Marco
    Vertulli, Daniele
    Vaccarino, Federica
    Mallio, Carlo Augusto
    Zobel, Bruno Beomonte
    Quattrocchi, Carlo Cosimo
    NEURORADIOLOGY JOURNAL, 2024, 37 (06): : 744 - 750
  • [26] High-resolution three-dimensional diffusion-weighted imaging of middle ear cholesteatoma at 3.0 T MRI: Usefulness of 3D turbo field-echo with diffusion-sensitized driven-equilibrium preparation (TFE-DSDE) compared to single-shot echo-planar imaging
    Yamashita, Koji
    Yoshiura, Takashi
    Hiwatashi, Akio
    Obara, Makoto
    Togao, Osamu
    Matsumoto, Nozomu
    Kikuchi, Kazufumi
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) : E471 - E475
  • [27] Improved detection of brain metastases using contrast-enhanced 3D black-blood TSE sequences compared to post-contrast 3D T1 GRE: a comparative study on 1.5-T MRI
    Zhou, Zhao Hui Chen
    Alvarez, Elena Salvador
    Hilario, Amaya
    del Carre, Agustin Cardenas
    Coronado, Juan Romero
    Lechuga, Carmen
    de Aragon, Ana Martinez
    Gonzalez, Ana Ramos
    EUROPEAN RADIOLOGY, 2025,
  • [28] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182