Determination of output factors for small proton therapy fields

被引:24
|
作者
Fontenot, Jonas D.
Newhauser, Wayne D.
Bloch, Charles
White, R. Allen
Titt, Uwe
Starkschall, George
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Biostat & Appl Math, Houston, TX 77030 USA
[4] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
关键词
proton therapy; Monte Carlo; patient-specific dose calibration; range compensator;
D O I
10.1118/1.2428406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Current protocols for the measurement of proton dose focus on measurements under reference conditions; methods for measuring dose under patient-specific conditions have not been standardized. In particular, it is unclear whether dose in patient-specific fields can be determined more reliably with or without the presence of the patient-specific range compensator. The aim of this study was to quantitatively assess the reliability of two methods for measuring dose per monitor unit (DIMU) values for small-field treatment portals: one with the range compensator and one without the range compensator. A Monte Carlo model of the Proton Therapy Center-Houston double-scattering nozzle was created, and estimates of DIMU values were obtained from 14 simulated treatments of a simple geometric patient model. Field-specific DIMU calibration measurements were simulated with a dosimeter in a water phantom with and without the range compensator. DIMU values from the simulated calibration measurements were compared with DIMU values from the corresponding treatment simulation in the patient model. To evaluate the reliability of the calibration measurements, six metrics and four figures of merit were defined to characterize accuracy, uncertainty, the standard deviations of accuracy and uncertainty, worst agreement, and maximum uncertainty. Measuring DIMU without the range compensator provided superior results for five of the six metrics and for all four figures of merit. The two techniques yielded different results primarily because of high-dose gradient regions introduced into the water phantom when the range compensator was present. Estimated uncertainties (similar to 1 mm) in the position of the dosimeter in these regions resulted in large uncertainties and high variability in DIMU values. When the range compensator was absent, these gradients were minimized and DIMU values were less sensitive to dosimeter positioning errors. We conclude that measuring DIMU without the range compensator present provides more reliable results than measuring it with the range compensator in place. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:489 / 498
页数:10
相关论文
共 50 条
  • [21] On the output factor measurements of the CyberKnife iris collimator small fields: Experimental determination of the kQclin,Qmsrfclin,fmsr correction factors for microchamber and diode detectors
    Pantelis, E.
    Moutsatsos, A.
    Zourari, K.
    Petrokokkinos, L.
    Sakelliou, L.
    Kilby, W.
    Antypas, C.
    Papagiannis, P.
    Karaiskos, P.
    Georgiou, E.
    Seimenis, I.
    [J]. MEDICAL PHYSICS, 2012, 39 (08) : 4875 - 4885
  • [22] Correction Factor in Output Measurement for Small Fields
    Srivastava, S.
    Das, I.
    Cheng, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2786 - +
  • [23] Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones (vol 40, 071725, 2013)
    Bassinet, C.
    Huet, C.
    Derreumaux, S.
    Brunet, G.
    Chea, M.
    Baumann, M.
    Lacornerie, T.
    Gaudaire-Josset, S.
    Trompier, F.
    Roch, P.
    Boisserie, G.
    Clairand, I.
    [J]. MEDICAL PHYSICS, 2013, 40 (11)
  • [24] Output Modeling for a Contemporary Proton Therapy Center
    Zheng, Y.
    Hsi, W.
    Harris, B.
    Ding, X.
    Jesseph, R.
    Mascia, A.
    Okoth, B.
    Wagner, A.
    Schreuder, A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [25] CALCULATION OF OUTPUT FACTORS FOR SHAPED ELECTRON FIELDS
    JACKSON, DD
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 533 - 533
  • [26] A Method to Assess the Need for Clinical Monte Carlo Dose Calculations for Small Proton Therapy Fields
    Bueno, M.
    Schuemann, J.
    Duch, M.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3874 - 3874
  • [27] A Practical Approach for the Determination of Small Field Output Factors Using Published Monte Carlo Derived Correction Factors
    Calderon, E.
    Siergiej, D.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 334 - 334
  • [28] Comprehensive investigation of lateral dose profile and output factor measurements in small proton fields from different delivery techniques
    Kretschmer, Jana
    Brodbek, Leonie
    Behrends, Carina
    Kugel, Fabian
    Koska, Benjamin
    Baeumer, Christian
    Wulff, Jorg
    Timmermann, Beate
    Poppe, Bjorn
    Looe, Hui Khee
    [J]. MEDICAL PHYSICS, 2023, 50 (07) : 4546 - 4561
  • [29] Defining field output factors in small fields based on dose area product measurements: A feasibility study
    Jurczak, Julien
    Rapp, Benjamin
    Bordy, Jean-Marc
    Josset, Stephanie
    Dufreneix, Stephane
    [J]. MEDICAL PHYSICS, 2024, 51 (05) : 3677 - 3686
  • [30] Detector specific output correction factors in small fields for different 2D detector arrays
    Gershkevitsh, E.
    Mendez, I.
    Casar, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1346 - S1346