Carrier frequency harmonic suppression in dual three-phase permanent magnet synchronous motor system

被引:4
|
作者
Zheng, Boyuan [1 ]
Xu, Yongxiang [1 ]
Wang, Guan [1 ]
Yu, Guodong [1 ]
Yan, Hao [2 ]
Wang, Minghui [1 ]
Zou, Jinbin [1 ]
机构
[1] Harbin Inst Technol, Dept Elect Engn, Harbin 150001, Heilongjiang, Peoples R China
[2] Univ Nottingham Ningbo China, Power Elect Machines & Control Grp, Ningbo, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
machine control; PWM invertors; harmonics suppression; switching convertors; synchronous motors; permanent magnet motors; pulse-width modulation wave; improved SVPWM strategy; 10 kHz carrier frequency; conventional SVPWM; 20 kHz carrier frequency; switching loss; high-frequency audible noise; existing mainstream SVPWM strategies; DTP-PMSM system; harmonic suppression ability; carrier frequency harmonic suppression; three-phase permanent magnet synchronous motor system; multiphase machines; three-phase PMSM; severe carrier frequency harmonic problem; harmonic subspace; improved space vector pulse-width modulation strategy; frequency; 10; 0; kHz; 20; INDUCTION-MOTOR; PWM; MODULATION; NOISE; INVERTER; STRATEGY; DESIGN;
D O I
10.1049/iet-epa.2019.0054
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dual three-phase permanent magnet synchronous motor (PMSM) is a major area of interest within the field of motors since it inherits the advantages of both the PMSM and multiphase machines. While dual three-phase PMSM (DTP-PMSM) system has a more severe carrier frequency harmonic problem due to the low impedance in the harmonic subspace, which will not only decrease the efficiency but also produce the high-frequency audible noise. This study proposes an improved space vector pulse-width modulation (SVPWM) strategy by changing the sequence of the pulse-width modulation wave. The improved SVPWM strategy with a 10 kHz carrier frequency has the same effect as the conventional SVPWM with a 20 kHz carrier frequency, which will significantly decrease the switching loss, lead to lower size of inductance, capacitance and eliminate the high-frequency audible noise. Three existing mainstream SVPWM strategies in DTP-PMSM system are introduced and the proposed strategy can be used in them without affecting their original advantages. The switching times are also minimised to reduce the switching loss. The theoretical derivation is proposed to prove the harmonic suppression ability of the proposed SVPWM and the implementation procedure is given then. The simulation and experimental results proved the effectiveness of the strategy.
引用
收藏
页码:1763 / 1772
页数:10
相关论文
共 50 条
  • [31] Model predictive control method with common-mode voltage suppression for dual three-phase permanent magnet synchronous motor
    Zhang, Zhifeng
    Wu, Yue
    Ye, Sicong
    [J]. INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2020, 64 (1-4) : 1453 - 1460
  • [32] Development of Three-Phase Permanent-Magnet Synchronous Motor Drive with Strategy to Suppress Harmonic Current
    Kao, Wei-Tse
    Hwang, Jonq-Chin
    Liu, Jia-En
    [J]. ENERGIES, 2021, 14 (06)
  • [33] A Novel Modeling for A Dual Three-phase Permanent Magnet Synchronous Machine
    Wang, Bulai
    Wei, Gu
    Chu, Jianxin
    Yi, Guo
    [J]. 2008 10TH INTERNATIONAL CONFERENCE ON CONTROL AUTOMATION ROBOTICS & VISION: ICARV 2008, VOLS 1-4, 2008, : 1630 - 1634
  • [34] Computation-Efficient Current Harmonic Mitigation for Dual Three-Phase Permanent Magnet Synchronous Motors
    Zhang, Zhen
    Zhang, Jiahui
    Han, Ruixue
    Wu, Yitong
    Gong, Yantian
    Chang, Siyuan
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (09)
  • [35] Sensorless control of dual three-phase permanent magnet synchronous motor based on speed feedback and frequency-variable tracking
    Gao, Hanying
    Dong, Yao
    [J]. PLOS ONE, 2023, 18 (11):
  • [36] A new adaptive dead time compensation method for dual three-phase permanent magnet synchronous motor
    Zhang, Xuefeng
    Xu, Qiwei
    Wang, Yiming
    Luo, Lingyan
    Yang, Yun
    [J]. ENERGY REPORTS, 2023, 9 : 267 - 277
  • [37] Fault Diagnosis Using Voltage Angle In Dual Three-Phase Interior Permanent Magnet Synchronous Motor
    Kang, Jun-Kyu
    Yoo, Dong-Wook
    Hur, Jin
    [J]. 2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [38] A Simple Current Sharing Scheme for Dual Three-Phase Permanent-Magnet Synchronous Motor Drives
    He, Yanhui
    Wang, Yue
    Wu, Jinlong
    Feng, Yupeng
    Liu, Jinjun
    [J]. 2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 1093 - 1096
  • [39] Harmonic closed-loop model predictive fault-tolerant control of a dual three-phase permanent magnet synchronous motor
    Cui J.
    Zhao W.
    Tao T.
    Huang L.
    Qiu X.
    [J]. Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2023, 53 (12): : 2137 - 2150
  • [40] Winding open circuit fault diagnosis method for dual three-phase permanent magnet synchronous motor
    Wang S.
    Xie S.
    Zhang Q.
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (05): : 108 - 116