Determination of carbazole and halogenated carbazoles in human serum samples using GC-MS/MS

被引:18
|
作者
Fang, Li [1 ,2 ]
Qiu, Fengmei [3 ]
Li, Ying [2 ]
Wang, Shizhong [2 ]
DeGuzman, Josephine [2 ]
Wang, Jun [4 ]
She, Jianwen [2 ]
机构
[1] Zhoushan Municipal Dist Ctr Dis Control & Prevent, Zhejiang Prov Key Lab Hlth Risk Factors Seafood, Zhoushan 316021, Peoples R China
[2] Calif Dept Publ Hlth, Environm Hlth Lab, 850 Marina Bay Pkwy, Richmond, CA 94804 USA
[3] Daishan Ctr Dis Control & Prevent, Daishan 316200, Zhejiang, Peoples R China
[4] Univ Oklahoma, Hlth Sci Ctr, Dept Occupat & Environm Hlth, Hudson Coll Publ Hlth, Oklahoma City, OK 73104 USA
关键词
Carbazole; Halogenated carbazole; Human serum; GC-MS/MS; Method development; Mass spectral characteristics; Biomonitoring; Emerging contaminants; LIQUID-LIQUID-EXTRACTION; POLYHALOGENATED CARBAZOLES; QUANTITATIVE-DETERMINATION; SALTING-OUT; SEDIMENTS; CHLOROCARBAZOLES; IDENTIFICATION; BIODEGRADATION; CHROMATOGRAPHY; CONTAMINANT;
D O I
10.1016/j.ecoenv.2019.109609
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Carbazole and halogenated carbazoles have been widely detected throughout the environment in soil, river deposits, and lake sediments. Human exposure to these compounds may occur through inhalation, drinking water, dietary intake and/or skin contact, and exposure levels in the body may be evaluated by measuring them in serum or blood. This paper reports the method development and validation for the analysis of carbazole and 11 halogenated carbazoles in human blood and/or serum samples. A small sample size of 100 mu L of blood or serum was employed for the analysis. The samples were prepared through salting-out liquid-liquid extraction (LLE) by using hexane/ethyl acetate (4:1, v/v) as the extraction solvent and aqueous MgSO4 (37.5 wt%) as the salting-out regent, respectively. Sample analysis was performed using gas-chromatography (GC) coupled with a tandem mass spectrometer (MS/MS) in an electron impact (EI) mode. The developed method demonstrated low detection limits in the range of 0.02-0.27 ng/mL, intra-day accuracy ranging from 81.2% to 125%, and inter-day accuracy from 91.0% to 117%. The infra- and inter-day precisions, calculated by relative standard deviations (RSDs), were in the ranges of 1.0-16.0% and 1.8-16.4%, respectively. The developed method was applied to the analysis of 50 human serum samples collected from pregnant women in Southern California in 2012. Low concentrations of carbazole were measured in 18 samples, while halogenated carbazoles were not detected in any of the samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Sensitive determination of midazolam and propofol in human plasma by GC-MS/MS
    Kaki, Yuki
    Fujishiro, Masaya
    Lee, Xiao-Pen
    Kato, Akihito
    Sakamoto, Yuki
    Hashimoto, Mari
    Minohara, Sawa
    Hasegawa, Chika
    Hasegawa, Iwao
    Dohi, Kenji
    Kumazawa, Takeshi
    Ishii, Akira
    Sato, Keizo
    Matsuyama, Takaaki
    [J]. FORENSIC TOXICOLOGY, 2020, 38 (02) : 409 - 419
  • [22] Separation of some halogenated phenols by GC-MS
    Aktas, A. Hakan
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2007, 19 (02) : 1411 - 1414
  • [23] Quantitative detection of carbazole and halogenated carbazoles in human blood samples
    She, Jianwen
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [24] Determination of Dithiocarbamate Mancozeb Residues in Milk Samples Using GC-MS Method
    Rao, Tentu Nageswara
    Cheedarala, Ravi Kumar
    [J]. ANALYTICAL CHEMISTRY LETTERS, 2019, 9 (06) : 845 - 852
  • [25] Chemometric Resolution for Rapid Determination of Prometryn in Leek Samples Using GC-MS
    Wu, Xi
    Yu, Weiwei
    Luo, Xiangyu
    Cai, Wensheng
    Shao, Xueguang
    [J]. CHROMATOGRAPHIA, 2013, 76 (13-14) : 849 - 855
  • [26] Analysis of pesticides in water samples using GC-ECD and GC-MS/MS techniques
    Pablos-Espada, MC
    Arrebola-Liébanas, FJ
    Garrido-Frenich, A
    Martínez-Vidal, JL
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 75 (1-2) : 165 - 179
  • [27] DETERMINATION OF ALKOXYGLYCEROLS BY GC-MS
    SEPPANEN, T
    LAAKSO, I
    HILTUNEN, R
    [J]. PLANTA MEDICA, 1988, (06) : 583 - 583
  • [28] DETERMINATION OF CLONAZEPAM BY GC-MS
    WILSON, JM
    RAISYS, VA
    [J]. CLINICAL CHEMISTRY, 1979, 25 (06) : 1090 - 1090
  • [29] Development and validation of a GC-MS/MS method for the determination of iodoacetic acid in biological samples
    Yu, Hanning
    Wu, Linying
    Xuan, Dongliang
    Peng, Qian
    Qu, Weidong
    Zhou, Ying
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (13) : 3185 - 3194
  • [30] ALLERGENS DETERMINATION BY GC-MS
    Culea, M.
    Iordache, A.
    Cozar, O.
    [J]. JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2010, 11 (02): : 523 - 528