Determination of carbazole and halogenated carbazoles in human serum samples using GC-MS/MS

被引:18
|
作者
Fang, Li [1 ,2 ]
Qiu, Fengmei [3 ]
Li, Ying [2 ]
Wang, Shizhong [2 ]
DeGuzman, Josephine [2 ]
Wang, Jun [4 ]
She, Jianwen [2 ]
机构
[1] Zhoushan Municipal Dist Ctr Dis Control & Prevent, Zhejiang Prov Key Lab Hlth Risk Factors Seafood, Zhoushan 316021, Peoples R China
[2] Calif Dept Publ Hlth, Environm Hlth Lab, 850 Marina Bay Pkwy, Richmond, CA 94804 USA
[3] Daishan Ctr Dis Control & Prevent, Daishan 316200, Zhejiang, Peoples R China
[4] Univ Oklahoma, Hlth Sci Ctr, Dept Occupat & Environm Hlth, Hudson Coll Publ Hlth, Oklahoma City, OK 73104 USA
关键词
Carbazole; Halogenated carbazole; Human serum; GC-MS/MS; Method development; Mass spectral characteristics; Biomonitoring; Emerging contaminants; LIQUID-LIQUID-EXTRACTION; POLYHALOGENATED CARBAZOLES; QUANTITATIVE-DETERMINATION; SALTING-OUT; SEDIMENTS; CHLOROCARBAZOLES; IDENTIFICATION; BIODEGRADATION; CHROMATOGRAPHY; CONTAMINANT;
D O I
10.1016/j.ecoenv.2019.109609
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Carbazole and halogenated carbazoles have been widely detected throughout the environment in soil, river deposits, and lake sediments. Human exposure to these compounds may occur through inhalation, drinking water, dietary intake and/or skin contact, and exposure levels in the body may be evaluated by measuring them in serum or blood. This paper reports the method development and validation for the analysis of carbazole and 11 halogenated carbazoles in human blood and/or serum samples. A small sample size of 100 mu L of blood or serum was employed for the analysis. The samples were prepared through salting-out liquid-liquid extraction (LLE) by using hexane/ethyl acetate (4:1, v/v) as the extraction solvent and aqueous MgSO4 (37.5 wt%) as the salting-out regent, respectively. Sample analysis was performed using gas-chromatography (GC) coupled with a tandem mass spectrometer (MS/MS) in an electron impact (EI) mode. The developed method demonstrated low detection limits in the range of 0.02-0.27 ng/mL, intra-day accuracy ranging from 81.2% to 125%, and inter-day accuracy from 91.0% to 117%. The infra- and inter-day precisions, calculated by relative standard deviations (RSDs), were in the ranges of 1.0-16.0% and 1.8-16.4%, respectively. The developed method was applied to the analysis of 50 human serum samples collected from pregnant women in Southern California in 2012. Low concentrations of carbazole were measured in 18 samples, while halogenated carbazoles were not detected in any of the samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] NSAIDs Determination in Human Serum by GC-MS
    Krokos, Adamantios
    Tsakelidou, Elisavet
    Michopoulou, Eleni
    Raikos, Nikolaos
    Theodoridis, Georgios
    Gika, Helen
    [J]. SEPARATIONS, 2018, 5 (03)
  • [2] Determination of organochlorine compounds in human biological samples by GC-MS/MS
    Frías, MM
    Torres, MJ
    Frenich, AG
    Vidal, JLM
    Olea-Serrano, F
    Olea, N
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (02) : 102 - 111
  • [3] Quantitative analysis of carbazoles and hydrocarbons in condensates and oils using comprehensive GC-MS/MS and comparative GC-MS analyses
    Easley, Daniella G.
    Malloy, Thomas B.
    Curiale, Joseph A.
    Bissada, K. K.
    [J]. ORGANIC GEOCHEMISTRY, 2022, 171
  • [4] Determination of Tyramine in Hair Samples by GC-MS
    Gao, Lina
    Yuan, Huiya
    Zhu, Juan
    Hara, Kenji
    Liu, Junting
    [J]. CHROMATOGRAPHIA, 2016, 79 (1-2) : 103 - 108
  • [5] Determination of Milnacipran in Human Plasma Using GC-MS
    Ucakturk, Ebru
    Safak, Cihat
    [J]. CHROMATOGRAPHIA, 2010, 72 (1-2) : 111 - 119
  • [6] Determination of phthalate esters in sediments and biological samples by GC-MS / MS
    Shi, Yanwei
    Wang, Liuyong
    Zhang, Rongrong
    Zhang, Zeming
    Sun, Aili
    Shi, Xizhi
    [J]. Chinese Journal of Analysis Laboratory, 2022, 41 (02) : 141 - 146
  • [7] Comparison of GC-MS and GCxGC-MS in the Analysis of Human Serum Samples for Biomarker Discovery
    Winnike, Jason H.
    Wei, Xiaoli
    Knagge, Kevin J.
    Colman, Steven D.
    Gregory, Simon G.
    Zhang, Xiang
    [J]. JOURNAL OF PROTEOME RESEARCH, 2015, 14 (04) : 1810 - 1817
  • [8] Application of GC-MS/MS technique for the determination of benzodiazepines in blood samples
    Banaszkiewicz, Laura
    Wozniak, Mateusz Kacper
    Kot-Wasik, Agata
    [J]. PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, : 131 - 137
  • [9] Determination of Voriconazole Concentrations in Serum by GC-MS
    Smith, Alisha
    Leung-Pineda, Van
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (05) : 411 - 417
  • [10] Determination of cutting agents in seized cocaine samples using GC-MS, GC-TMS and LC-MS/MS
    Fiorentin, Tais Regina
    Fogarty, Melissa
    Limberger, Renata Pereira
    Logan, Barry Kerr
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2019, 295 : 199 - 206