Closed-loop control system robustness improvement by a parameterised state feedback

被引:7
|
作者
Ibbini, MS
Alawneh, SR
机构
[1] Jordan Univ Sci & Technol, Dept Elect Engn, Irbid, Jordan
[2] Yarmouk Univ, Hijjawi Fac Appl Engn, Irbid, Jordan
来源
关键词
state feedback; robustness; parameterisation; eigenvalues assignment;
D O I
10.1049/ip-cta:19981545
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
State feedback is one of the most popular and well known techniques for altering the transient response of a closed-loop system. This technique is usually used to assign the eigenvalues of a closed-loop system to desired locations under the assumption of complete controllability. In the case of multi-input systems, the feedback gain matrix permitting the assignment of a desired set of eigenvalues is nonunique and, hence, different gain matrices can be used. This non-uniqueness of the gain matrix offers extra degrees of freedom that permit the designers not only to place the closed-loop system eigenvalues but also to satisfy some performance indices beyond the eigenvalues assignment problem. One important performance measure is the closed-loop system robustness to parameter variations or to external disturbances. Closed-loop system robustness is often a major concern of control designers, since design is usually based on nominal values of system parameters which are rarely those of normal operations. This paper considers closed-loop system robustness to two types of system deviations from nominal or ideal design conditions.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [21] The inherent robustness of closed-loop scheduling
    McAllister, Robert D.
    Rawlings, James B.
    Maravelias, Christos T.
    COMPUTERS & CHEMICAL ENGINEERING, 2022, 159
  • [22] The inherent robustness of closed-loop scheduling
    McAllister, Robert D.
    Rawlings, James B.
    Maravelias, Christos T.
    Computers and Chemical Engineering, 2022, 159
  • [23] CLOSED-LOOP FEEDBACK-CONTROL OF THE NYCTOHEMERAL RISE IN ADRENOCORTICAL SYSTEM FUNCTION
    AKANA, SF
    SHINSAKO, J
    DALLMAN, MF
    FEDERATION PROCEEDINGS, 1985, 44 (01) : 177 - 181
  • [24] Adaptive closed-loop power control with quantized feedback and loop filtering
    Su, HJ
    Geraniotis, E
    IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2002, 1 (01) : 76 - 86
  • [25] Adaptive closed-loop power control with quantized feedback and loop filtering
    Su, HJ
    Geraniotis, E
    NINTH IEEE INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR AND MOBILE RADIO COMMUNICATIONS, VOLS 1-3, 1998, : 926 - 931
  • [26] On the Existence of Steady State Oscillations in Closed-Loop Feedback Systems
    Stofanik, Vladimr
    Minarik, Marin
    Cocherova, Elena
    2015 25TH INTERNATIONAL CONFERENCE RADIOELEKTRONIKA (RADIOELEKTRONIKA), 2015, : 94 - 97
  • [27] Channel State Information Feedback with Zero-Overhead in Closed-Loop MIMO System
    Zhang, Yiheng
    Cui, Qimei
    Zhang, Ping
    Tao, Xiaofeng
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2010, E93B (01) : 9 - 15
  • [28] Injection molding quality control by integrating weight feedback into a cascade closed-loop control system
    Chen, Zhongbao
    Turng, Lih-Sheng
    POLYMER ENGINEERING AND SCIENCE, 2007, 47 (06): : 852 - 862
  • [29] Creating the Feedback Loop Closed-Loop Neurostimulation
    Hebb, Adam O.
    Zhang, Jun Jason
    Mahoor, Mohammad H.
    Tsiokos, Christos
    Matlack, Charles
    Chizeck, Howard Jay
    Pouratian, Nader
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2014, 25 (01) : 187 - +
  • [30] Mechanical Blender Control for Closed-Loop Oxygenation Feedback Control Systems
    Tejkl, Leos
    Petrova, Zuzana
    Kudrna, Petr
    Rafl, Jakub
    ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 2, EHB-2023, 2024, 110 : 373 - 380