Iodine Vapor Staining for Atomic Number Contrast in Backscattered Electron and X-Ray Imaging

被引:37
|
作者
Boyde, Alan [1 ]
Mccorkell, Fergus A. [2 ]
Taylor, Graham K. [2 ]
Bomphrey, Richard J. [3 ]
Doube, Michael [4 ]
机构
[1] Queen Mary Univ London, Barts & London Sch Med & Dent, London E1 4NS, England
[2] Univ Oxford, Dept Zool, Oxford Anim Flight Grp, Oxford OX1 3PS, England
[3] Royal Vet Coll, Dept Comparat Biomed Sci, Struct & Mot Lab, Hatfield AL9 7TA, Herts, England
[4] Univ London Royal Vet Coll, Dept Comparat Biomed Sci, London NW1 0TU, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
SEM; microCT; desublimation; attenuation; segmentation; soft tissue; histology; MICRO-COMPUTED TOMOGRAPHY; SHRINKAGE; TISSUES; AGENTS;
D O I
10.1002/jemt.22435
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Iodine imparts strong contrast to objects imaged with electrons and X-rays due to its high atomic number (53), and is widely used in liquid form as a microscopic stain and clinical contrast agent. We have developed a simple technique which exploits elemental iodine's sublimation-deposition state-change equilibrium to vapor stain specimens with iodine gas. Specimens are enclosed in a gas-tight container along with a small mass of solid I-2. The bottle is left at ambient laboratory conditions while staining proceeds until empirically determined completion (typically days to weeks). We demonstrate the utility of iodine vapor staining by applying it to resin-embedded tissue blocks and whole locusts and imaging them with backscattered electron scanning electron microscopy (BSE SEM) or X-ray microtomography (XMT). Contrast is comparable to that achieved with liquid staining but without the consequent tissue shrinkage, stain pooling, or uneven coverage artefacts associated with immersing the specimen in iodine solutions. Unmineralized tissue histology can be read in BSE SEM images with good discrimination between tissue components. Organs within the locust head are readily distinguished in XMT images with particularly useful contrast in the chitin exoskeleton, muscle and nerves. Here, we have used iodine vapor staining for two imaging modalities in frequent use in our laboratories and on the specimen types with which we work. It is likely to be equally convenient for a wide range of specimens, and for other modalities which generate contrast from electron- and photon-sample interactions, such as transmission electron microscopy and light microscopy. Microsc. Res. Tech. 77:1044-1051, 2014. (c) 2014 The Authors. Microscopy Research Technique published by Wiley Periodocals, Inc.
引用
收藏
页码:1044 / 1051
页数:8
相关论文
共 50 条
  • [31] Correction for atomic number in X-ray electron probe microanalysis by spectra of reflected electrons
    N. P. Il’in
    Journal of Analytical Chemistry, 2015, 70 : 1092 - 1102
  • [32] Correction for Atomic Number in X-ray Electron Probe Microanalysis by Spectra of Reflected Electrons
    Il'in, N. P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (09) : 1092 - 1102
  • [33] ANALYSIS OF BACKSCATTERED ELECTRON SIGNALS FOR X-RAY MASK INSPECTION.
    Rosenfield, Michael G.
    1600,
  • [34] Intermetallic texture analysis by X-ray, neutron and electron backscattered diffraction
    Baudin, T
    Dahms, M
    Quesne, C
    Penelle, R
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C2): : 141 - 146
  • [35] Optimal contrast for X-ray phase-contrast imaging
    College of Medical Instrument, University of Shanghai Science and Technology, Shanghai 200093, China
    不详
    Guangzi Xuebao, 2008, 6 (1217-1220):
  • [36] Determination of free iodine concentration in an X-ray contrast agent
    Kljubin, V. V.
    Kljubina, K. A.
    Makovetskaya, K. N.
    OPTICS AND SPECTROSCOPY, 2016, 120 (04) : 546 - 550
  • [37] Determination of free iodine concentration in an X-ray contrast agent
    V. V. Kljubin
    K. A. Kljubina
    K. N. Makovetskaya
    Optics and Spectroscopy, 2016, 120 : 546 - 550
  • [38] THE DEVELOPMENT OF ORGANIC IODINE COMPOUNDS AS X-RAY CONTRAST MEDIA
    WALLINGFORD, VH
    JOURNAL OF THE AMERICAN PHARMACEUTICAL ASSOCIATION-SCIENTIFIC EDITION, 1953, 42 (12): : 721 - 728
  • [39] On analyzing of the contrast for X-ray phase-contrast imaging
    Liu, S.
    Zhang, X. L.
    Huang, Y.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1168 - 1171
  • [40] DETERMINATION OF INHERENT CONTRAST RESOLUTION IN X-RAY-IMAGING USING ELECTRON-DENSITY AND EFFECTIVE ATOMIC-NUMBER DIFFERENCES
    DIBIANCA, FA
    FETTER, JE
    BARKER, MD
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 454 : 28 - 35