Three-dimensional T1ρ-weighted MRI at 1.5 Tesla

被引:49
|
作者
Borthakur, A [1 ]
Wheaton, A [1 ]
Charagundla, SR [1 ]
Shapiro, EM [1 ]
Regatte, RR [1 ]
Akella, SVS [1 ]
Kneeland, JB [1 ]
Reddy, R [1 ]
机构
[1] Univ Penn, Dept Radiol, Stellar Chance Labs B1, Philadelphia, PA 19104 USA
关键词
T1; rho; cartilage; spin-lock; RF heating; SAR;
D O I
10.1002/jmri.10296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three-dimensional T-1rho-weighted MRI on a 1.5-T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects. Materials and Methods: A three-pulse cluster was pre-encoded to a three-dimensional gradient-echo imaging sequence to create a three-dimensional, T-1rho-weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom-built knee-coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T-1rho values measured by this sequence to those obtained with a previously tested two-dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI-based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T-1rho-weighted images of the knee joint of a healthy individual. Results: Calculated T-1rho of articular cartilage in the specimen was similar for both and three-dimensional and two-dimensional methods (84+/-2 msec and 80+/-3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015degreesC, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues. Conclusion: We developed and implemented a three-dimensional T-1rho-weighted pulse sequence on a 1.5-T clinical scanner.
引用
收藏
页码:730 / 736
页数:7
相关论文
共 50 条
  • [31] Three-dimensional vessel wall imaging with 1.5-T MRI to visualize invisible occluded cerebral artery
    Kumagai, Kosuke
    Hayashi, Miyuka
    Takahashi, Takahiro
    Honma, Hiroyuki
    Nishida, Shou
    Hayashi, Shinji
    Ishihara, Hideaki
    ACTA RADIOLOGICA, 2023, 64 (12) : 3052 - 3055
  • [32] Fast and Quantitative T1ρ-weighted Dynamic Glucose Enhanced MRI
    Schuenke, Patrick
    Paech, Daniel
    Koehler, Christina
    Windschuh, Johannes
    Bachert, Peter
    Ladd, Mark E.
    Schlemmer, Heinz-Peter
    Radbruch, Alexander
    Zaiss, Moritz
    SCIENTIFIC REPORTS, 2017, 7
  • [33] T1 relaxometry of the thalamus in clinically isolated syndrome using 7 Tesla MRI
    Lim, S. Y.
    Al-Radaideh, A.
    Tench, C.
    Gowland, P.
    Constantinescu, C.
    MULTIPLE SCLEROSIS, 2009, 15 (09): : S208 - S209
  • [34] Fast and Quantitative T1ρ-weighted Dynamic Glucose Enhanced MRI
    Patrick Schuenke
    Daniel Paech
    Christina Koehler
    Johannes Windschuh
    Peter Bachert
    Mark E. Ladd
    Heinz-Peter Schlemmer
    Alexander Radbruch
    Moritz Zaiss
    Scientific Reports, 7
  • [35] Three-dimensional simultaneous brain T1, T2, and ADC mapping with MR Multitasking
    Ma, Sen
    Nguyen, Christopher T.
    Han, Fei
    Wang, Nan
    Deng, Zixin
    Binesh, Nader
    Moser, Franklin G.
    Christodoulou, Anthony G.
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 72 - 88
  • [36] Rapid Parametric Mapping of the Longitudinal Relaxation Time T1 Using Two-Dimensional Variable Flip Angle Magnetic Resonance Imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla
    Dieringer, Matthias A.
    Deimling, Michael
    Santoro, Davide
    Wuerfel, Jens
    Madai, Vince I.
    Sobesky, Jan
    von Knobelsdorff-Brenkenhoff, Florian
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    PLOS ONE, 2014, 9 (03):
  • [37] Whole-Brain Three-Dimensional T2-Weighted BOLD Functional Magnetic Resonance Imaging at 7 Tesla
    Hua, Jun
    Qin, Qin
    van Zijl, Peter C. M.
    Pekar, James J.
    Jones, Craig K.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1530 - 1540
  • [38] T2prep three-dimensional spiral imaging with efficient whole brain coverage for myelin water quantification at 1.5 tesla
    Nguyen, Thanh D.
    Wisnieff, Cynthia
    Cooper, Mitchell A.
    Kumar, Dushyant
    Raj, Ashish
    Spincemaille, Pascal
    Wang, Yi
    Vartanian, Tim
    Gauthier, Susan A.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 614 - 621
  • [39] Usefulness of three-dimensional T1-weighted spoiled gradient-recalled echo and three-dimensional heavily T2-weighted images in preoperative evaluation of spinal dysraphism
    Nobuya Murakami
    Takato Morioka
    Kimiaki Hashiguchi
    Takashi Yoshiura
    Akio Hiwatashi
    Satoshi O. Suzuki
    Akira Nakamizo
    Toshiyuki Amano
    Nobuhiro Hata
    Tomio Sasaki
    Child's Nervous System, 2013, 29 : 1905 - 1914
  • [40] High resolution three dimensional intracranial arterial wall imaging at 3 T using T1 weighted SPACE
    Zhang, Lei
    Zhang, Na
    Wu, Jun
    Zhang, Lijuan
    Huang, Yanyan
    Liu, Xin
    Chung, Yiu-Cho
    MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1026 - 1034