Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity

被引:25
|
作者
Arvidsson, Daniel [1 ]
Fridolfsson, Jonatan [1 ]
Borjesson, Mats [1 ,2 ,3 ]
Andersen, Lars Bo [4 ,5 ]
Ekblom, Orjan [6 ]
Dencker, Magnus [7 ]
Brond, Jan Christian [8 ]
机构
[1] Univ Gothenburg, Ctr Hlth & Performance, Dept Food & Nutr & Sport Sci, Skanegatan 14b,Box 300, SE-40530 Gothenburg, Sweden
[2] Univ Gothenburg, Inst Neurosci & Physiol, Dept Physiol, Gothenburg, Sweden
[3] Sahlgrenska Univ Hospital Ostra, Gothenburg, Sweden
[4] Western Norway Univ Appl Sci, Fac Educ Arts & Sport, Sogndal, Norway
[5] Norwegian Sch Sport Sci, Dept Sports Med, Oslo, Norway
[6] Swedish Sch Sport & Hlth Sci, Astrand Lab Work Physiol, Stockholm, Sweden
[7] Lund Univ, Dept Translat Med, Clin Physiol, Malmo, Sweden
[8] Univ Southern Denmark, Dept Sport Sci & Clin Biomech, RICH EXE, Odense, Denmark
关键词
acceleration; counts; energy expenditure; frequency filtering; mechanical work; FREE-LIVING ACTIVITIES; ENERGY-EXPENDITURE; COMPUTER-SCIENCE; ACTIVITY MONITORS; AMERICAN-COLLEGE; ACTIGRAPH GT3X; PUBLIC-HEALTH; WALKING; VALIDATION; VALIDITY;
D O I
10.1111/sms.13470
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This review re-examines the use of accelerometer and oxygen uptake data for the assessment of activity intensity. Accelerometers capture mechanical work, while oxygen uptake captures the energy cost of this work. Frequency filtering needs to be considered when processing acceleration data. A too restrictive filter attenuates the acceleration signal for walking and, to a higher degree, for running. This measurement error affects shorter (children) more than taller (adults) individuals due to their higher movement frequency. Less restrictive filtering includes more movement-related signals and provides measures that better capture mechanical work, but may include more noise. An optimal filter cut-point is determined where most relevant acceleration signals are included. Further, accelerometer placement affects what part of mechanical work being captured. While the waist placement captures total mechanical work and therefore contributes to measures of activity intensity equivalent by age and stature, the thigh and wrist placements capture more internal work and do not provide equivalent measures. Value calibration of accelerometer measures is usually performed using measured oxygen uptake with the metabolic equivalent of task (MET) as reference measure of activity intensity. However, the use of MET is not stringent and is not a measure of activity intensity equivalent by age and stature. A candidate measure is the mass-specific net oxygen uptake, VO(2)net (VO(2)tot - VO(2)stand). To improve measurement of physical activity intensity using accelerometers, research developments are suggested concerning the processing of accelerometer data, use of energy expenditure as reference for activity intensity, and calibration procedure with absolute versus relative intensity.
引用
收藏
页码:1442 / 1452
页数:11
相关论文
共 50 条
  • [1] Calibration of the GENEA accelerometer for assessment of physical activity intensity in children
    Phillips, Lisa R. S.
    Parfitt, Gaynor
    Rowlands, Alex V.
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2013, 16 (02) : 124 - 128
  • [2] A Biomechanical Re-Examination of Physical Activity Measurement with Accelerometers
    Fridolfsson, Jonatan
    Borjesson, Mats
    Arvidsson, Daniel
    [J]. SENSORS, 2018, 18 (10)
  • [3] A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    Bouten, CVC
    Koekkoek, KTM
    Verduin, M
    Kodde, R
    Janssen, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) : 136 - 147
  • [4] Calibration of GENEActiv accelerometer wrist cut-points for the assessment of physical activity intensity of preschool aged children
    Roscoe, Clare M. P.
    James, Rob S.
    Duncan, Michael J.
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (08) : 1093 - 1098
  • [5] Calibration of GENEActiv accelerometer wrist cut-points for the assessment of physical activity intensity of preschool aged children
    Clare M. P. Roscoe
    Rob S. James
    Michael J. Duncan
    [J]. European Journal of Pediatrics, 2017, 176 : 1093 - 1098
  • [6] INTENSITY OF EFFECT OF VARIOUS DOSES OF OPIATES - RE-EXAMINATION OF FORTHS EXPERIMENTAL DATA
    SARRIS, V
    [J]. PSYCHOLOGISCHE BEITRAGE, 1968, 10 (02): : 165 - 172
  • [7] A RE-EXAMINATION OF SOALS CLAIRVOYANCE DATA
    FOSTER, EB
    [J]. JOURNAL OF PARAPSYCHOLOGY, 1956, 20 (02) : 110 - 120
  • [8] Calibration of raw accelerometer data to measure physical activity: A systematic review
    Mendes, Marcio de Almeida
    da Silva, Inacio C. M.
    Ramires, Virgilio V.
    Reichert, Felipe F.
    Martins, Rafaela C.
    Tomasi, Elaine
    [J]. GAIT & POSTURE, 2018, 61 : 98 - 110
  • [9] Lost in a haystack: The importance of physical re-examination
    Jain, Dheeraj
    Viswanathan, Stalin
    Shanmugam, Jagatheeswari
    [J]. JOURNAL OF INFECTION AND PUBLIC HEALTH, 2014, 7 (05) : 450 - 452
  • [10] EPR SIGNAL INTENSITY AND POWDER SHAPES - RE-EXAMINATION
    AASA, R
    VANNGARD, T
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1975, 19 (03) : 308 - 315